Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000320/LER-1981-030, Forwards LER 81-030/01L-0 + (05:48:24, 20 December 2024)
- IR 05000302/1981024 + (05:48:26, 20 December 2024)
- ML20038D060 + (05:48:27, 20 December 2024)
- PNO-I-81-131, on 811209,steam Leak from iso-condenser Isolation Valve Resulted in Removal of iso-condenser from Svc.Probably Caused by Limit Switch Bypassing to Backseat Valve.Plant Shut Down to Repair Valves Using Same Procedure + (05:48:29, 20 December 2024)
- ML20038D055 + (05:48:31, 20 December 2024)
- ML20038D057 + (05:48:31, 20 December 2024)
- ML20038D054 + (05:48:32, 20 December 2024)
- ML20038D053 + (05:48:34, 20 December 2024)
- ML20038D051 + (05:48:34, 20 December 2024)
- ML20038D049 + (05:48:35, 20 December 2024)
- ML20038D047 + (05:48:37, 20 December 2024)
- ML20038D046 + (05:48:41, 20 December 2024)
- ML20038D045 + (05:48:44, 20 December 2024)
- ML20038D044 + (05:48:46, 20 December 2024)
- ML20038D040 + (05:48:47, 20 December 2024)
- ML20038D041 + (05:48:47, 20 December 2024)
- ML20038D038 + (05:48:48, 20 December 2024)
- 05000311/LER-1981-117-03, /03L-0:on 811110,svc Water Inlet Valve Position Indicator for One Containment Fan Coil Unit Indicated Not Open & Low Water Flow for Another.First Caused by Defective Limit Switch & Second by Silt in Flow Transmitter Line + (05:48:49, 20 December 2024)
- 05000311/LER-1981-117, Forwards LER 81-117/03L-0.Detailed Event Analysis Encl + (05:48:51, 20 December 2024)
- 05000272/LER-1981-112-03, /03L-0:on 811106,auxiliary Feed Storage Tank Afst Found Below Min Level.Caused by Use of Afst to Feed Steam Generators Following Reactor Trip.Demineralized Water Makeup Initiated + (05:48:53, 20 December 2024)
- 05000272/LER-1981-112, Forwards LER 81-112/03L-0.Detailed Event Analysis Encl + (05:48:55, 20 December 2024)
- 05000311/LER-1981-116-03, /03L-0:on 811107,charging Pump Tripped Electrically on long-term Overcurrent During Operation & Attempted Restart.Caused by Broken Impeller Shaft.Rotating Assembly Replaced + (05:48:57, 20 December 2024)
- 05000272/LER-1981-113-03, /03L-0:on 811108,steam Generator Level 14 Channel 3 Failed High.Caused by Dual Comparator Failure.Comparator Replaced + (05:48:59, 20 December 2024)
- ML20038D023 + (05:49:00, 20 December 2024)
- 05000272/LER-1981-111-03, /03L-0:on 811106,containment Fan Coil Unit 11 Failed to Start in Low Speed Mode After Safety Injection Signal.Caused by Failure of Automatic Trip Shutter on Low Speed Circuit Breaker to Close When Breaker Racked in + (05:49:01, 20 December 2024)
- 05000272/LER-1981-113, Forwards LER 81-113/03L-0.Detailed Event Analysis Encl + (05:49:03, 20 December 2024)
- IR 05000423/1981011 + (05:49:05, 20 December 2024)
- 05000311/LER-1981-116, Forwards LER 81-116/03L-0.Detailed Event Analysis Encl + (05:49:06, 20 December 2024)
- 05000271/LER-1981-030-03, /03L-0:on 811104,cracks Found Near Seating Surfaces of Reactor Water Cleanup Valves V12-29A & B,V12-19A & B & V12-73A & B.Cause Unknown.Valves Replaced.Epri Will Analyze V12-29A & 73A + (05:49:08, 20 December 2024)
- 05000272/LER-1981-111, Forwards LER 81-111/03L-0.Detailed Event Analysis Encl + (05:49:10, 20 December 2024)
- 05000280/LER-1981-067-03, /03L-0:on 811111,trip Valve TV-CC-109B (Component Cooling Isolation) Failed to Close Remotely from Control Room.Caused by Hole in Diaphragm Due to Normal Wear.Entire Positioner Replaced + (05:49:19, 20 December 2024)
- 05000311/LER-1981-114-01, /01T-0:on 811119,reactor Coolant Leakage Exceeded Tech Spec Limit.Caused by Svc Water Leaking from Pinhole in Containment Fan Coil Unit 22 Motor Cooler.Motor Cooler Replaced + (05:49:21, 20 December 2024)
- 05000311/LER-1981-114, Forwards LER 81-114/01T-0.Detailed Event Analysis Encl + (05:49:23, 20 December 2024)
- ML20038D002 + (05:49:25, 20 December 2024)
- ML20038D004 + (05:49:25, 20 December 2024)
- 05000289/LER-1981-012-04, /04L-0:on 811116,ETS 2.2.1.a,limiting Condition for Riverwater Chlorination,Was Exceeded.Caused by Malfunctioning Timing Device.Faulty Timer Repaired.Tech Spec Change Request 100A Allows Condition to Equal NPDES Permit + (05:49:26, 20 December 2024)
- ML20038D000 + (05:49:28, 20 December 2024)
- ML20038C999 + (05:49:29, 20 December 2024)
- 05000289/LER-1981-012, Forwards LER 81-012/04L-0 + (05:49:30, 20 December 2024)
- ML20038C995 + (05:49:32, 20 December 2024)
- GO2-81-493, Final Deficiency Rept 144 Re Possible Installation of Defective 2-inch Schedule Pipe,Initially Reported on 811106. Extensive Testing Indicated That Piping Would Have No Adverse Effect on Plant.Condition Not Reportable + (05:49:33, 20 December 2024)
- ML20038C989 + (05:49:33, 20 December 2024)
- ML20038C986 + (05:49:36, 20 December 2024)
- IR 05000354/1981017 + (05:49:37, 20 December 2024)
- ML20038C983 + (05:49:38, 20 December 2024)
- GO2-81-492, Final Deficiency Rept 80,re Pipe Weld ASME Defects,Initially Reported on 800319.Pipe Wall Thickness Was Less than Specified Min Wall But Above Code Required Thickness. Condition Determined Not Reportable Per 10CFR50.55e + (05:49:39, 20 December 2024)
- 05000334/LER-1981-097-03, /03L-0:on 811102,below Normal Readings Were Observed on Containment Particulate Air Monitor RM-215A. Caused by Decreased Sample Flow.Flow Increased by Opening Manual Throttling Valve + (05:49:41, 20 December 2024)
- 05000339/LER-1981-085-03, /03L-0:on 811112,boron Concentration in Casing Cooling Tank Found Out of Spec High.Caused by Use of Better Method for Analyzing Boron Samples.Tank Partially Drained, Filled W/Unboronated Water & Placed on Recirculation + (05:49:43, 20 December 2024)
- 05000334/LER-1981-097, Forwards LER 81-097/03L-0 + (05:49:45, 20 December 2024)
- ML20038C977 + (05:49:46, 20 December 2024)
- 05000369/LER-1981-172-03, /03L-0:on 811031,while Preparing for Unit Startup, Loop T Avg Deviation,Loop D/T Deviation & Lo-Lo T Avg Alert Alarmed on Control Room Annunciator.Caused by Malfunctioned NRA Card.Card Replaced + (05:49:47, 20 December 2024)