- 05000369/LER-1982-028, Forwards LER 82-028/03L-0 + (10:08:50, 18 December 2024)
- 05000251/LER-1982-005-03, /03L-0:on 820414,when Attempting to Fill Condensate Storage Tank After Low Level Alarm,Level Fell Below Acceptable Limit.Caused by Open Manual Valve DWDS-001 Allowing Flow to Demineralized Water Storage Tank + (10:08:52, 18 December 2024)
- 05000302/LER-1982-032-03, /03L-0:on 820412,emergency Diesel Generator 1B Failed to Meet Starting Time Criteria.Caused by Manual Timing Techniques Used for Determining Elapsed Start Time. Methods for Improving Techniques Under Investigation + (10:08:54, 18 December 2024)
- 05000251/LER-1982-005, Forwards LER 82-005/03L-0 + (10:08:55, 18 December 2024)
- 05000366/LER-1982-031-03, /03L-0:on 820415,switches 2E11-N010B & D, 2E11-N011B,contacts 1 & 2 & 2E11-N011D,contact 1,actuated Outside of Tech Spec Range.Caused by Setpoint Drift.Switches Recalibr & Returned to Svc + (10:09:00, 18 December 2024)
- 05000366/LER-1982-031, Forwards LER 82-031/03L-0.Detailed Event Analysis Encl + (10:09:06, 18 December 2024)
- 05000366/LER-1982-033-03, /03L-0:on 820419,during Reactor Core Isolation Cooling Steamline Differential Pressure Instrument Functional Test & calibr,2E51-NO17 Actuated at +105 Inches of Water.Caused by Setpoint Drift.Switch Recalibr + (10:09:08, 18 December 2024)
- 05000361/LER-1982-011-01, /01T-0:on 820313,only Operable Control Room Airborne Radiation Monitor Removed from Svc,Violating Tech Spec 3.3.2.b for Approx 2-h.Caused by Personnel Error. Personnel Cautioned + (10:09:10, 18 December 2024)
- 05000361/LER-1982-011, Forwards LER 82-011/01T-0.Detailed Event Analysis Submitted + (10:09:12, 18 December 2024)
- 05000321/LER-1982-030-03, /03L-0:on 820421,while Performing HPCI Motor Operated Valve Operability,Redundant Shutoff Valve 1E41-F011 Failed to Close Fully W/Control Switch.Caused by Mechanical Overload Switch Set at Min Setting + (10:09:14, 18 December 2024)
- 05000366/LER-1982-033, Forwards LER 82-033/03L-0 + (10:09:18, 18 December 2024)
- 05000302/LER-1982-032, Forwards LER 82-032/03L-0 + (10:09:20, 18 December 2024)
- 05000369/LER-1982-027-03, /03L-0:on 820326,one Channel of Position Indication for RCS Power Operated Relief Valves NC-32 & NC-36 Declared Inoperable When Closed Indicator Lights Failed.Caused by Loose Fitting Bulb Due to Crack in Socket + (10:09:22, 18 December 2024)
- 05000321/LER-1982-030, Forwards LER 82-030/03L-0 + (10:09:24, 18 December 2024)
- ML20052H580 + (10:09:30, 18 December 2024)
- ML20052H579 + (10:09:31, 18 December 2024)
- 05000369/LER-1982-027, Forwards LER 82-027/03L-0 + (10:09:32, 18 December 2024)
- ML20052H575 + (10:09:39, 18 December 2024)
- ML20052H574 + (10:09:40, 18 December 2024)
- ML20052H573 + (10:09:46, 18 December 2024)
- ML20052H570 + (10:09:46, 18 December 2024)
- ML20052H569 + (10:09:47, 18 December 2024)
- ML20052H568 + (10:09:49, 18 December 2024)
- ML20052H567 + (10:09:54, 18 December 2024)
- ML20052H565 + (10:09:57, 18 December 2024)
- 05000296/LER-1982-010-03, /03L-0:on 820406,during Refueling & Routine Performance of SI 4.2.F-10,pressure Switch 3-PS-64-67 Had as-found Calibr of 35.5 Psig.Caused by Setpoint Drift.Model 50-560-111AAAC1 Alarm Recalibr + (10:09:59, 18 December 2024)
- ML20052H563 + (10:10:00, 18 December 2024)
- ML20052H561 + (10:10:06, 18 December 2024)
- AECM-82-201, Final Deficiency Rept Re Broken Sample Probe on Recirculation Loop a Discharge Riser Spool Found in Reactor Vessel Bottom Head Area,Initially Reported 820406.Sample Probe for Unit 1 Replaced.Also Reportable Per Part 21 + (10:10:07, 18 December 2024)
- ML20052H558 + (10:10:09, 18 December 2024)
- 05000296/LER-1982-010, Forwards LER 82-010/03L-0 + (10:10:11, 18 December 2024)
- ML20052H555 + (10:10:12, 18 December 2024)
- ML20052H554 + (10:10:12, 18 December 2024)
- 05000321/LER-1982-019-03, /03L-0:on 820330 During Surveillance of Fire Barrier Penetration Seals,Seals Found Breached in Areas of Control Bldg.Caused by Personnel Failure to Comply W/ Procedure HNP-1-6908M.Fire Watches Established + (10:10:14, 18 December 2024)
- 05000338/LER-1982-024-03, /03L-0:on 820416,I-131 Dose Equivalent Exceeded 1.0 Mci/G Tech Spec Limit.Caused by Fuel Element Defect in Reactor core.Post-trip Conditions Enhanced Release of Fission Fragment Causing Iodine Spike.Rcs Returned Normal + (10:10:16, 18 December 2024)
- ML20052H550 + (10:10:23, 18 December 2024)
- 05000321/LER-1982-019, Forwards LER 82-019/03L-0 + (10:10:25, 18 December 2024)
- ML20052H547 + (10:10:26, 18 December 2024)
- 05000338/LER-1982-024, Forwards LER 82-024/03L-0 + (10:10:27, 18 December 2024)
- ML20052H543 + (10:10:29, 18 December 2024)
- ML20052H542 + (10:10:30, 18 December 2024)
- 05000338/LER-1982-023-03, /03L-0:on 820416,containment Average Temp Exceeded Max Limit.Caused by Loss of Auxiliary Steam to Chilled Water Sys Following Reactor Trip.Auxiliary Steam Pressure Restored & Chilled Water Sys Properly Adjusted + (10:10:31, 18 December 2024)
- ML20052H540 + (10:10:32, 18 December 2024)
- ML20052H537 + (10:10:33, 18 December 2024)
- ML20052H536 + (10:10:34, 18 December 2024)
- 05000338/LER-1982-023, Forwards LER 82-023/03L-0 + (10:10:35, 18 December 2024)
- ML20052H533 + (10:10:40, 18 December 2024)
- ML20052H532 + (10:10:42, 18 December 2024)
- ML20052H530 + (10:10:43, 18 December 2024)
- ML20052H529 + (10:10:44, 18 December 2024)
- ML20052H528 + (10:10:45, 18 December 2024)