Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000277/LER-1978-036-03, /03L-0 on 780901:failure of Auxiliary Oil Pump to Start Due to a Ground in Motor.Motor,Baldor Type 1040D, 7 1/2 H.P.,25OV.D.C. Was Replaced & HPCI Sys Tested Satisfactorily W/In 36 Hours.Ads Timers Not W/In Tech Specs + (02:09:00, 17 December 2024)
- 05000278/LER-1978-016-03, /03L-0 on 780904:during Surveillance Test Unit 3 Dmain Steam Radiat Monitor Failed to Cause a Half Scram Due to Defective Transistor.Transitor Was Replaced & Monitor Returned to Svc in 6 Hours + (02:09:02, 17 December 2024)
- 05000277/LER-1978-037-03, /03L-0 on 780901:while Testing ADS Subsys,Timers on Both Loops Were Found Outside the 115-125 Second Limit of Tech Specs Due to Setpoint Drift of Time Delay Relays. Timers Were Calibrated,Retested & Returned to Svc + (02:09:03, 17 December 2024)
- 05000280/LER-1978-004-03, /03X-1 on 780305:loss of Svc Water Flow Through Charging Pump Intermediate Seal Cooler Was Caused by Corrosion of Stem of Discharge Gate Valve;Corrosion Was Galvanic(Brass Touching Bronze);Problem Will Be Studied + (02:09:09, 17 December 2024)
- 05000219/LER-1978-018-01, /01T-0 on 780916:3 MSIVs(NS03A,NS04A,NS04B) Had Leakage Rates in Excess of Maximum Allowable Due to Stem Packing,Cracked Stellite Weld & Failure of Main Poppet to Seat Properly.Msiv Failures Being Investigated + (02:09:11, 17 December 2024)
- ML20064B735 + (02:09:12, 17 December 2024)
- 05000219/LER-1978-018, Forwards LER 78-018/01T-0 + (02:09:14, 17 December 2024)
- ML20064B729 + (02:09:15, 17 December 2024)
- 05000281/LER-1978-011, Forwards LER 78-011/03X-1 + (02:09:16, 17 December 2024)
- LIC-94-0052, Forwards Rev 7 to Site Security Plan & Detailed Summary Listing of Changes Made in Rev,Including Revised Plan Format.Rev Withheld (Ref 10CFR73.21) + (02:09:17, 17 December 2024)
- ML20064B725 + (02:09:18, 17 December 2024)
- 05000325/LER-1978-071-03, /03L-0 on 780905:during Periodic Test,Radiat Monitor D12-RM-NO10B HI-HI Trip Point Drifted to Higher than Permitted Level.Monitor Recalibrated.Drift Appears to Be Isolated Incident;No Further Action Taken + (02:09:19, 17 December 2024)
- ML20064B722 + (02:09:20, 17 December 2024)
- ML20064B721 + (02:09:20, 17 December 2024)
- ML20064B719 + (02:09:21, 17 December 2024)
- 05000325/LER-1978-071, Forwards LER 78-071/03L-0 + (02:09:22, 17 December 2024)
- ML20064B717 + (02:09:23, 17 December 2024)
- JAFP-94-0124, Forwards Rev 3 to Security Contingency Plan.Encl Withheld (Ref 10CFR73.21) + (02:09:27, 17 December 2024)
- JAFP-94-0125, Forwards Modified Amended Security Force Training & Qualification Plan,Rev 4.Encl Withheld + (02:09:27, 17 December 2024)
- 05000259/LER-1978-028-01, /01T-0 on 780919:Foxboro Model 610 Pwr Supplies Provided Under TVA Contact 75K11-8680 Were Not Seismically Qualified,Qualified Pwr Supplies Have Been Provided & Will Be Installed + (02:09:29, 17 December 2024)
- ML20064B711 + (02:09:30, 17 December 2024)
- 05000259/LER-1978-028, Forwards LER 78-028/01T + (02:09:33, 17 December 2024)
- 05000311/LER-1982-140-03, /03L-0:on 821121,while Performing Surveillance Procedure SP(0)4.6.1.3 on 130 Ft Elevation Containment Airlock,Leakage Rate Exceeded Tech Specs.Caused by Excessive Air Flow Past Inner Door Seal.Seal Repositioned + (02:09:35, 17 December 2024)
- 05000334/LER-1978-048-03, /03L-0 on 780221:during Rev Test Data on 780825, Noted That Final Setpoint Valve Entered on 780221 for RCS Loop 1B Cold Leg Loop Stop Valve Relief Line Flow Interlock Was 124 Gpm Caused by Improper Setpoint + (02:09:36, 17 December 2024)
- 05000334/LER-1978-048, Forwards LER 78-048/03L-0 + (02:09:38, 17 December 2024)
- 05000311/LER-1982-140, Forwards LER 82-140/03L-0.Detailed Event Analysis Encl + (02:09:39, 17 December 2024)
- ML20064B695 + (02:09:40, 17 December 2024)
- ML20064B694 + (02:09:40, 17 December 2024)
- 05000247/LER-1978-024, Forwards LER 78-024/04L-0 + (02:09:45, 17 December 2024)
- ML20064B691 + (02:09:46, 17 December 2024)
- ML20064B665 + (02:09:46, 17 December 2024)
- ML20064B663 + (02:09:47, 17 December 2024)
- IR 05000413/2019006 + (02:09:48, 17 December 2024)
- ML20064B645 + (02:09:49, 17 December 2024)
- ML20064B658 + (02:09:49, 17 December 2024)
- ML20064B633 + (02:09:51, 17 December 2024)
- ML20064B631 + (02:09:52, 17 December 2024)
- ML20064B625 + (02:09:53, 17 December 2024)
- ML20064B613 + (02:09:53, 17 December 2024)
- HL-1067, Application for Amends to Licenses DPR-57 & NPF-5, Incorporating Changes to Plant Onsite QA Organizations & Slightly Modifying Plant Review Board Responsibilities + (02:09:54, 17 December 2024)
- ML20064B606 + (02:09:55, 17 December 2024)
- ML20064B601 + (02:09:56, 17 December 2024)
- ML20064B596 + (02:09:57, 17 December 2024)
- ML20064B581 + (02:09:58, 17 December 2024)
- ML20064B568 + (02:09:59, 17 December 2024)
- ML20064B570 + (02:09:59, 17 December 2024)
- RBG-33767, Revises 900830 Response to Deviations Noted in Insp Rept 50-458/90-16 on 900709-19.Corrective Actions:Bright Green Self Adhesive Paper Dots Installed on Reg Guide 1.97 Type A,B & C Instruments Designated Category 1 or 2 + (02:10:00, 17 December 2024)
- ML20064B504 + (02:10:01, 17 December 2024)
- ML20064B540 + (02:10:01, 17 December 2024)
- ML20064B498 + (02:10:02, 17 December 2024)
- ELV-02171, Forwards Amend 19 to Physical Security & Contingency Plan. Amend Withheld (Ref 10CFR73.21) + (02:10:03, 17 December 2024)