- 05000293/LER-1982-023-01, /01T-0:on 820813,during Personnel Access to Torus Room,Removable Hand Rail Fell Against Steam hi-flow Dpis(S) Resulting in Scram.Caused by Personnel Error. Hand Rails Removed + (01:16:20, 17 December 2024)
- ML20064N073 + (01:16:21, 17 December 2024)
- ML20064N070 + (01:16:24, 17 December 2024)
- ML20064N069 + (01:16:25, 17 December 2024)
- 05000317/LER-1982-046-03, /03L-0:on 820729,channel a Reactor Protective Sys Axial Shape Index Indication Discovered Out of Calibr.Caused by Improper Coefficient Setting Description & Value in Setpoint File.File Revised & Channels Verified in Spec + (01:16:26, 17 December 2024)
- 05000293/LER-1982-023, Forwards LER 82-023/01T-0 + (01:16:27, 17 December 2024)
- ML20064N061 + (01:16:29, 17 December 2024)
- ML20064N058 + (01:16:29, 17 December 2024)
- ML20064N053 + (01:16:30, 17 December 2024)
- 05000317/LER-1982-047-03, /03L-0:on 820730,during Surveillance Testing, Channel C Reactor Protective Sys Low Flow Trip Setpoint Was Nonconservative.Caused by Improper Setting of Trip Units. Setpoint Corrected + (01:16:31, 17 December 2024)
- 05000361/LER-1982-047-01, /01L-0:on 820714,auxiliary Feedwater Sys Valve 2HV4714 Was Slow in Stroking Open Rendering Motor Driven Pump 2P-504 Inoperable.Caused by Metal Shaving Found in Solenoid.Newly Calibr Solenoid Valve Installed + (01:16:33, 17 December 2024)
- 05000317/LER-1982-047, Forwards LER 82-047/03L-0 + (01:16:34, 17 December 2024)
- 05000361/LER-1982-047, Forwards LER 82-047/01L-0.Detailed Event Analysis Submitted + (01:16:35, 17 December 2024)
- ML20064N007 + (01:16:37, 17 December 2024)
- ML20064N004 + (01:16:37, 17 December 2024)
- ML20064N003 + (01:16:38, 17 December 2024)
- 05000361/LER-1982-073-01, /01T-0:on 820826,min Level for Refueling Water Storage Tank Found to Be 87.5% Instead of 75% as Stated in Procedures S023-3-3.25 & S023-3-3.27.Caused by Misinterpretation of Words ECCS Suction Connection + (01:16:40, 17 December 2024)
- ML20064M995 + (01:16:41, 17 December 2024)
- ML20064M997 + (01:16:41, 17 December 2024)
- 05000361/LER-1982-073, Forwards LER 82-073/01T-0.Detailed Event Analysis Submitted + (01:16:42, 17 December 2024)
- 05000443/LER-1994-001-01, :on 940125,reactor Trip & Safety Injection Occurred Due to Inadvertent MSIV Closure.Caused by Hydraulic Fluid Contamination,Sticking Main Dump Valve & Related Hardware Issues.Msivs Disassembled & Inspected + (01:16:44, 17 December 2024)
- ML20064M982 + (01:16:45, 17 December 2024)
- ML20064M987 + (01:16:45, 17 December 2024)
- ML20064M973 + (01:16:46, 17 December 2024)
- ML20064M981 + (01:16:46, 17 December 2024)
- ML20064M967 + (01:16:47, 17 December 2024)
- 05000277/LER-1982-045-03, /03L-0:on 821230,while Performing Routine Decontamination of RHR Pump Room 2B,motor Found Wet to Extent Considered Inoperable.Caused by Personnel Error. Supervisor Reinstructed Vendor in Proper Method + (01:16:48, 17 December 2024)
- ML20064M961 + (01:16:49, 17 December 2024)
- ML20064M960 + (01:16:50, 17 December 2024)
- ML20064M955 + (01:16:51, 17 December 2024)
- ML20064M956 + (01:16:51, 17 December 2024)
- ML20064M947 + (01:16:52, 17 December 2024)
- ML20064M949 + (01:16:52, 17 December 2024)
- ML20064M946 + (01:16:53, 17 December 2024)
- ML20064M943 + (01:16:55, 17 December 2024)
- 05000361/LER-1982-077-03, /03L-0:on 820725,containment Pressure Indicators 2P1-0351-2 & 2P1-0352-2 Failed Channel Check Test.Caused by Instrument Drift.Indicators Recalibr + (01:16:56, 17 December 2024)
- ML20064M936 + (01:16:57, 17 December 2024)
- 05000361/LER-1982-159-03, Pressure Indicator 2PI-8300 for Steam Generator E-088 on Essential Plant Parameter Monitoring Sys Panel 21-411 Read Greater than Similar Indicator on Control Room Panel CR-52.Cause Unknown + (01:17:01, 17 December 2024)
- ML20064M931 + (01:17:05, 17 December 2024)
- W3P83-0430, Notifies That Compliance w/NUREG-0737,Item II.E.4.2 Re Containment Pressure Setpoint (3.3 Psig),Has Been Calculated Using Explicit Setpoint Methodology Per SER Open Item. Info Will Be Included in FSAR Amend 31 + (01:17:05, 17 December 2024)
- ML20064M930 + (01:17:06, 17 December 2024)
- ML20064M929 + (01:17:08, 17 December 2024)
- 05000361/LER-1982-077, Forwards LER 82-077/03L-0.Detailed Event Analysis Submitted + (01:17:12, 17 December 2024)
- 05000255/LER-1982-021-03, /03L-0:on 820729,during Surveillance of Hydraulic Snubbers,Snubber 31 Contained Insufficient Oil.Caused by Deteriorated O-rings.Failed Snubber Replaced + (01:17:17, 17 December 2024)