- ML20065K057 + (00:35:56, 17 December 2024)
- IR 05000373/1982037 + (00:35:57, 17 December 2024)
- ML20065K052 + (00:35:58, 17 December 2024)
- 05000296/LER-1982-042, Forwards LER 82-042/03L-0 + (00:35:59, 17 December 2024)
- ML20065K045 + (00:36:00, 17 December 2024)
- ML20065K044 + (00:36:03, 17 December 2024)
- 05000333/LER-1993-022, :on 931029,wires Between RPS Scram Contractor Were Not Installed Inside Protective Conduits.Caused by Inadequate Design & Design Review.Corrective Action:Eight Resistors Were Relocated + (00:36:05, 17 December 2024)
- ML20065K038 + (00:36:06, 17 December 2024)
- ML20065K035 + (00:36:07, 17 December 2024)
- 05000263/LER-1982-008-03, /03L-0:on 820830,RCIC Barometer Condenser Cooling Water Supply Valve Failed.Caused by Severed Stem Due to Rotork Motor Operator Torque Switch Misadjustment.Valve Stem Replaced + (00:36:09, 17 December 2024)
- ML20065K030 + (00:36:10, 17 December 2024)
- ML20065K028 + (00:36:13, 17 December 2024)
- ML20065K025 + (00:36:14, 17 December 2024)
- ML20065K021 + (00:36:14, 17 December 2024)
- 05000263/LER-1982-008, Forwards LER 82-008/03L-0 + (00:36:15, 17 December 2024)
- ML20065K018 + (00:36:16, 17 December 2024)
- W3P90-1539, Forwards Public Version of Revised Epips,Including Rev 15 to EP-001-030 & Rev 15 to EP-001-040.W/DH Grimsley 901108 Release Memo + (00:36:16, 17 December 2024)
- ML20065K013 + (00:36:17, 17 December 2024)
- ML20065K009 + (00:36:18, 17 December 2024)
- ML20065K005 + (00:36:19, 17 December 2024)
- 05000373/LER-1982-099-03, /03L-0:on 820830,svc Water Liquid Process Radiation Monitor Drifted High & Declared Inoperative. Caused by Electronic Failure of Gamma Detector.Work Request Initiated to Correct Problem + (00:36:20, 17 December 2024)
- ML20065J990 + (00:36:21, 17 December 2024)
- ML20065J987 + (00:36:22, 17 December 2024)
- ML20065J989 + (00:36:22, 17 December 2024)
- ELV-02215, Special Rept 2-90-04:on 901009,invalid Diesel Generator Failure Occurred + (00:36:23, 17 December 2024)
- 05000373/LER-1982-099, Forwards LER 82-099/03L-0 + (00:36:24, 17 December 2024)
- ML20065J978 + (00:36:25, 17 December 2024)
- 05000366/LER-1982-090-03, /03L-0:on 820831,during Quarterly Surveillance, B Oxygen Analyzer Failed to Calibr Due to Instrument Fluctuation.Caused by Worn Pump Head Assembly on Sample Pumps.Upper & Lower Pump Heads Replaced.Analyzer Recalibr + (00:36:27, 17 December 2024)
- ML20065J969 + (00:36:28, 17 December 2024)
- ML20065J974 + (00:36:28, 17 December 2024)
- 05000366/LER-1982-090, Forwards LER 82-090/03L-0 + (00:36:29, 17 December 2024)
- ML20065J967 + (00:36:29, 17 December 2024)
- ML20065J966 + (00:36:30, 17 December 2024)
- ML20065J964 + (00:36:31, 17 December 2024)
- 05000336/LER-1994-004-02, :on 940319,failure to Perform Adequate ASME Leakage Test Discovered.Caused by Personnel Error & Procedural Deficiency.Valve Bypassed & Isolated + (00:36:32, 17 December 2024)
- ML20065J954 + (00:36:33, 17 December 2024)
- ML20065J948 + (00:36:34, 17 December 2024)
- 05000339/LER-1990-006-02, :on 901015,pressurizer Power Operated Relief Valves Not Properly Tested Due to Personnel Error + (00:36:35, 17 December 2024)
- ML20065J934 + (00:36:36, 17 December 2024)
- ML20065J932 + (00:36:37, 17 December 2024)
- ML20065J933 + (00:36:37, 17 December 2024)
- ML20065J926 + (00:36:38, 17 December 2024)
- 05000423/LER-1994-006, :on 940315,determined That Portions of AFW System Did Not Meet Design Requirements for Normal Use. Caused by Design Error.Afw Line Caution Tagged to Alert Personnel + (00:36:40, 17 December 2024)
- B10564, Application to Amend License DPR-65,revising Tech Specs Re Boric Acid Flow Path Requirements as Utilized in Reactivity Control Sys & ECCS + (00:36:41, 17 December 2024)
- ML20065J916 + (00:36:41, 17 December 2024)
- ML20065J911 + (00:36:42, 17 December 2024)
- ML20065J908 + (00:36:43, 17 December 2024)
- ML20065J889 + (00:36:44, 17 December 2024)
- ML20065J906 + (00:36:44, 17 December 2024)
- ML20065J888 + (00:36:45, 17 December 2024)
- 05000416/LER-1982-052-03, /03L-0:on 820831,required Number of RHR Shutdown Cooling Mode Loops Were Inoperable When Plant Conditions Changed from Mode 5 to Mode 4.Caused by Operator Error in Misinterpreting License Exemptions.Operator Reinstructed + (00:36:47, 17 December 2024)