Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20066A927 + (23:44:39, 16 December 2024)
- ML20066A913 + (23:44:40, 16 December 2024)
- 05000318/LER-1982-045-03, /03L-0:on 821001,reactor Protection Sys Low Flow Trip Unit on Channel a Failed.Caused by Failed Low Power Supply (Lambda Part LCD-2-44).Failed Power Supply Replaced & Sent to Vendor for Analysis & Repair + (23:44:41, 16 December 2024)
- 05000255/LER-1982-034, Forwards LER 82-034/03L-0 + (23:44:42, 16 December 2024)
- ML20066A905 + (23:44:43, 16 December 2024)
- 05000311/LER-1982-115-03, /03L-0:on 820928,svc Water Leak Found on 2A Emergency Diesel Generator Oil Cooler Piping.Caused by Silt in Svc Water Triggering Accelerated Erosion.Failed Pipe Cap Replaced + (23:44:44, 16 December 2024)
- 05000318/LER-1982-045, Forwards LER 82-045/03L-0 + (23:44:45, 16 December 2024)
- 05000311/LER-1982-115, Forwards LER 82-115/03L-0.Detailed Event Analysis Encl + (23:44:46, 16 December 2024)
- ML20066A892 + (23:44:47, 16 December 2024)
- ML20066A889 + (23:44:47, 16 December 2024)
- ML20066A887 + (23:44:48, 16 December 2024)
- ML20066A879 + (23:44:49, 16 December 2024)
- RBG-13-412, Corrected Final Deficiency Rept DR-38 Re Difference in Serration Patterns of PS-10RS Spring Nuts.Addl Clarification of Dichromated PS-9227RS-1/2 Nut & Corrected Typographical Errors Incorporated + (23:44:49, 16 December 2024)
- ML20066A871 + (23:44:50, 16 December 2024)
- ML20066A872 + (23:44:50, 16 December 2024)
- ML20066A865 + (23:44:51, 16 December 2024)
- ML20066A864 + (23:44:51, 16 December 2024)
- ML20066A860 + (23:44:55, 16 December 2024)
- ML20066A862 + (23:44:55, 16 December 2024)
- ML20066A858 + (23:44:57, 16 December 2024)
- ML20066A857 + (23:44:57, 16 December 2024)
- ML20066A856 + (23:44:58, 16 December 2024)
- ML20066A854 + (23:44:59, 16 December 2024)
- ML20066A852 + (23:45:00, 16 December 2024)
- ML20066A849 + (23:45:01, 16 December 2024)
- 05000373/LER-1982-133-03, /03L-0:on 820930,RHR Svc Water 1C Pump auto-tripped During LOP-RH-09,rendering Pump Inoperable. Caused by Motor Failure Due to Phase to Ground Fault in Motor Field Windings.Motor Replaced + (23:45:03, 16 December 2024)
- ML20066A847 + (23:45:04, 16 December 2024)
- ML20066A844 + (23:45:05, 16 December 2024)
- ML20066A838 + (23:45:06, 16 December 2024)
- ML20066A841 + (23:45:06, 16 December 2024)
- ML20066A835 + (23:45:07, 16 December 2024)
- 05000373/LER-1982-133, Forwards LER 82-133/03L-0 + (23:45:08, 16 December 2024)
- A820020, Forwards Revision to Inservice Testing Relief Requests Re Pump Vibration Testing + (23:45:08, 16 December 2024)
- NRC-90-0170, Responds to Violations Noted in Insp Rept 50-341/90-18. Corrective Actions:Personnel Assigned to Survey Radioactive Matl Shipments Will Receive Training on Revised Procedure 67.000.103 Re Survey of Radwaste Shipment Vehicles + (23:45:09, 16 December 2024)
- ML20066A826 + (23:45:09, 16 December 2024)
- NRC-90-0186, Submits Update to Simulator Upgrade Project Schedule. Exemption Request from 10CFR50.12, Specific Exemptions Will Be Submitted in Jan 1991 to Provide Required Simulator Certification to NRC Later in 1991 + (23:45:10, 16 December 2024)
- 05000373/LER-1982-112-03, /03L-0:on 820929,during Performance of LIS-NB-01, DPIS-1B21-N024D Setpoint for Reactor Vessel Low Water Level Scram Found Out of Calibr.Caused by Instrument Drift.Switch Recalibr.Revision in Progress to Change Tolerance Setp + (23:45:12, 16 December 2024)
- ML20066A816 + (23:45:13, 16 December 2024)
- ML20066A814 + (23:45:14, 16 December 2024)
- 05000311/LER-1982-114-03, /03L-0:on 820927,RMS Apd Filter Drive Unit Malfunctioned.Caused by Slipped Pin Attaching Solenoid Arm to Ratchet Cog.Pin Installed Through Bottom Instead of Top of Connecting Sleeve.Pin Reinstalled Correctly + (23:45:16, 16 December 2024)
- 05000373/LER-1982-112, Forwards LER 82-112/03L-0 + (23:45:17, 16 December 2024)
- ML20066A795 + (23:45:17, 16 December 2024)
- B10589, Informs of Integrated Leak Rate Testing Schedule.Test Will Be Performed at End of 1983 Refueling Outage + (23:45:18, 16 December 2024)
- 05000311/LER-1982-114, Forwards LER 82-114/03L-0.Detailed Event Analysis Encl + (23:45:19, 16 December 2024)
- ML20066A769 + (23:45:19, 16 December 2024)
- ML20066A768 + (23:45:20, 16 December 2024)
- ML20066A729 + (23:45:29, 16 December 2024)
- 05000317/LER-1982-060-04, /04X-0:on 820827,oyster Samples Showed Higher than Normal Concentration of Ag-110m.Caused by Natural Tendency of Oysters to Concentrate Environ Silver.All Releases in First Half of 1982 within Tech Spec Allowable Limits + (23:45:31, 16 December 2024)
- 05000237/LER-1982-019-03, Thermocouple on Electromatic Relief Valve 2-203-3D Failed Open.Caused by Broken Ceramic Insulator in Thermocouple Head & Twisted Wires Due to Improper Installation.Thermocouple Replaced + (23:45:34, 16 December 2024)
- 05000334/LER-1982-039-03, /03L-0:on 820912,control Rod H-14 Analog Position Found 15 Steps Below Group Step Counter Demand Position. Caused by Primary to Secondary Voltage Signal Conditioning Module Drift.Module Removed for Insp & Returned to Svc + (23:45:36, 16 December 2024)
- ML20066A711 + (23:45:37, 16 December 2024)