- 05000339/LER-1982-080-03, /03L-0:on 821206,during Mode 1,individual RPI for Rod H-02 in Control Bank D Deviated from Group Demand Position by Greater than 12 Steps W/No Rod Motion.Caused by Instrument Drift.Rpi Channel Recalibr & Returned to Svc + (14:30:30, 16 December 2024)
- L-82-547, Interim Deficiency Rept Re Lack of Documentation on Class I & II Bolts & Nuts.Initially Reported on 821013.Final Rept Will Be Submitted by 830126 + (14:30:31, 16 December 2024)
- ML20070K682 + (14:30:31, 16 December 2024)
- 05000339/LER-1982-080, Forwards LER 82-080/03L-0 + (14:30:32, 16 December 2024)
- ML20070K666 + (14:30:36, 16 December 2024)
- ML20070K673 + (14:30:36, 16 December 2024)
- ML20070K662 + (14:30:37, 16 December 2024)
- 05000338/LER-1982-087-03, /03L-0:on 821205,during Mode 1,individual RPI for Rod H-02 in Control Bank D Deviated from Group Demand Position by Greater than 12 Steps W/No Rod Motion.Caused by Instrument Drift.Rpi Channel Recalibr & Returned to Svc + (14:30:39, 16 December 2024)
- ML20070K654 + (14:30:40, 16 December 2024)
- ML20070K655 + (14:30:40, 16 December 2024)
- 05000338/LER-1982-087, Forwards LER 82-087/03L-0 + (14:30:41, 16 December 2024)
- ML20070K649 + (14:30:42, 16 December 2024)
- ML20070K645 + (14:30:43, 16 December 2024)
- ML20070K643 + (14:30:44, 16 December 2024)
- 05000339/LER-1982-078-03, /03L-0:on 821205,during Mode 1,containment Average Air Temp Exceeded 105 F.Caused by Temp Increase of Chilled Water to Containment Air Recirculation Cooling Coils Due to Temporary Inoperability of Mechanical Refrigeration Un + (14:30:46, 16 December 2024)
- ML20070K639 + (14:30:47, 16 December 2024)
- 05000338/LER-1982-084-03, /03L-0:on 821205,at 20% Power,Channels FI-1475 & FI-1485 for Steam Generators a & B Steam Flow Showed Below Actual Flow.Caused by Transmitter for FI-1475 & Multiplier/ Divider/Square Root for FI-1485 Being Out of Calibr + (14:30:49, 16 December 2024)
- 05000339/LER-1982-078, Forwards LER 82-078/03L-0 + (14:30:51, 16 December 2024)
- ML20070K627 + (14:30:51, 16 December 2024)
- ML20070K624 + (14:30:53, 16 December 2024)
- ML20070K621 + (14:30:54, 16 December 2024)
- 05000364/LER-1982-050-03, /03L-0:on 821124,source Range Channel N32 Declared Inoperable Due to Erratic Readings.Caused by Faulty Detector on N31 & Faulty High Voltage Power Supply Cable Connector on N32.Detector & Cable Connector Replaced + (14:30:55, 16 December 2024)
- 05000338/LER-1982-084, Forwards LER 82-084/03L-0 + (14:30:56, 16 December 2024)
- ML20070K606 + (14:30:59, 16 December 2024)
- BSEP-82-2906, RO 1-82-154:on 821214,while Detensioning Reactor Vessel Head,Operational Mode 5 Entered W/O Meeting Tech Spec 3.0.4 Requirements.Investigation Underway & Mode 5 Requirements Under Review + (14:31:00, 16 December 2024)
- 05000364/LER-1982-048-03, /03L-0:on 821127,source Range Channel N-32 Declared Inoperable Due to Loss of Detector Voltage.Caused by Faulty High Voltage Connector.Connector Replaced + (14:31:02, 16 December 2024)
- ML20070K595 + (14:31:03, 16 December 2024)
- ML20070K594 + (14:31:03, 16 December 2024)
- 05000325/LER-1982-127, Updated LER 82-127/01T-1:on 821103,quick Start Testing of Diesel Generators 2,3 & 4 Not Performed for 12 H Period Per Tech Spec.Caused by Failure to Enter Requirement Into Daily Surveillance Rept on 821102.Testing Performed + (14:31:04, 16 December 2024)
- ML20070K585 + (14:31:05, 16 December 2024)
- ML20070K586 + (14:31:05, 16 December 2024)
- ML20070K567 + (14:31:08, 16 December 2024)
- 05000338/LER-1982-082-01, /01T-0:on 821206,both Trains of Automatic Safety Injection Blocked for 22 H & 30 Minutes Following Inadvertent Safety Injection.Caused by Emergency Procedure Which Misled Operators.Procedure Revised + (14:31:10, 16 December 2024)
- ML20070K563 + (14:31:11, 16 December 2024)
- ML20070K564 + (14:31:11, 16 December 2024)
- 05000338/LER-1982-082, Forwards LER 82-082/01T-0 + (14:31:12, 16 December 2024)
- ML20070K548 + (14:31:13, 16 December 2024)
- ML20070K545 + (14:31:13, 16 December 2024)
- ML20070K544 + (14:31:14, 16 December 2024)
- ML20070K542 + (14:31:14, 16 December 2024)
- ML20070K538 + (14:31:15, 16 December 2024)
- ML20070K536 + (14:31:16, 16 December 2024)
- ML20070K515 + (14:31:17, 16 December 2024)
- ML20070K512 + (14:31:18, 16 December 2024)
- ML20070K510 + (14:31:19, 16 December 2024)
- ML20070K498 + (14:31:20, 16 December 2024)
- ML20070K494 + (14:31:20, 16 December 2024)
- ML20070K490 + (14:31:22, 16 December 2024)
- ML20070K485 + (14:31:22, 16 December 2024)
- ML20070K476 + (14:31:24, 16 December 2024)
- ML20070K484 + (14:31:24, 16 December 2024)