Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000317/LER-1982-076-03, /03L-0:on 821219,during Performance of Routine Test,Containment Air Cooler Fan 12 Would Not Shift to Low Speed or Manually Start in Slow Speed.Caused by Relay Contacts Not Making Proper Contact.Relay Will Be Replaced + (14:17:16, 16 December 2024)
- 05000317/LER-1982-076, Forwards LER 82-076/03L-0 + (14:17:17, 16 December 2024)
- ML20070P692 + (14:17:18, 16 December 2024)
- 05000416/LER-1982-176-99, /99X-0:on 821215 & 17,fire Barriers AE-290 & 1H13-4732 Opened to Route Cables Used for Mods to Transient Test Sys.Work Currently in Progress to Reseal Barriers + (14:17:20, 16 December 2024)
- 05000416/LER-1982-176, Forwards LER 82-176/99X-0 + (14:17:21, 16 December 2024)
- AECM-83-020, Final Deficiency Rept PRD-82/37 Re Failure of Qualified Cables to Pass IEEE Flame Test.Initially Reported on 821214. Design Change DCP-82/3196 Initiated.Also Reported Per Part 21 + (14:17:21, 16 December 2024)
- 05000387/LER-1982-077-03, /03L-0:on 821217,one HPCI Steam Line Sensor Setpoint Found Out of Allowable Value Range.Caused by Instrument Drift.Revised Setpoints for Instrument Determined & Surveillance Procedure Changed + (14:17:28, 16 December 2024)
- 05000387/LER-1982-077, Forwards LER 82-077/03L-0 + (14:17:29, 16 December 2024)
- ST-HL-AE-3711, Proposes Alternative Wording for NRC SER on Util Turbine Sys Maint Program,Submitted to Util Via NRC .Changes Cover Insp Invervals for Low Pressure Turbines & Insp of Low Pressure Turbine Rotors + (14:17:29, 16 December 2024)
- ML20070P606 + (14:17:35, 16 December 2024)
- 05000220/LER-1982-023-03, /03L-0:on 821218,while Performing Local Leak Rate Testing,Valve 201.2-71 Exceeded Tech Specs.Caused by Poor Seating Resulting from Dirt & Corrosion.Valve Will Be Cleaned Followed by Retest + (14:17:37, 16 December 2024)
- NG-94-1378, Responds to NRC Generic Ltr 89-10,suppl 5, Inaccuracy of MOV Diagnostic Equipment + (14:17:38, 16 December 2024)
- ML20070P591 + (14:17:39, 16 December 2024)
- ML20070P581 + (14:17:45, 16 December 2024)
- 05000277/LER-1991-007, :on 910221,RHR Mo Inboard Isolation Valve MO-2-10-25B Closed on Isolation Signal.Caused by Specified Blocking Permit Less than Adequate.Permit Writers Directed to Walkdown Permits + (14:17:46, 16 December 2024)
- ML20070P563 + (14:17:49, 16 December 2024)
- ML20070P562 + (14:17:50, 16 December 2024)
- 05000220/LER-1982-022-03, /03L-0:on 821218,while Performing Local Leak Rate Testing,Leakage from Valves 201.2-27 & 201.2-28 Exceeded Tech Specs.Caused by Poor Seating Resulting from Dirt & Corrosion.Valves Will Be Cleaned + (14:17:51, 16 December 2024)
- ML20070P552 + (14:17:52, 16 December 2024)
- BECO-91-038, Submits Annual Rept of Property Damage Insurance Coverage, Per 10CFR50.54(w) + (14:17:53, 16 December 2024)
- ML20070P519 + (14:17:53, 16 December 2024)
- 05000220/LER-1982-021-03, /03L-0:on 821215,while Performing Local Leak Rate Testing,Leakage from Valves 39-11,39-12,39-13 & 39-14 Exceeded Tech Specs.Caused by Dry Packing Condition Resulting from Current Shutdown.Valves Will Be Repacked + (14:17:55, 16 December 2024)
- ML20070P512 + (14:17:56, 16 December 2024)
- 05000382/LER-1991-002-01, :on 910221,inadvertent Control Room Outside Air Isolation Due to Equipment Malfunction.Beta Radiation Window Light Was Replaced & Returned to Svc + (14:17:57, 16 December 2024)
- 05000333/LER-1983-001-04, /04T-0:on 821230,number of Fish Impinged During 24 H Period Exceeded 20,000.Caused by Bad Weather Conditions Experienced During Sampling.Sampling Continued Until Fish Count Fell Below 20,000 + (14:17:59, 16 December 2024)
- 05000220/LER-1982-020-03, /03L-0:on 821213,while Performing Local Leak Rate Testing,Leakage from Valves 58.1-01 & 58.1-02 Exceeded Tech Specs.Caused by Valve Order.Existing Order Modified W/Check Valve Followed by Gate Valve + (14:18:01, 16 December 2024)
- ML20070P492 + (14:18:02, 16 December 2024)
- ML20070P489 + (14:18:03, 16 December 2024)
- ML20070P484 + (14:18:04, 16 December 2024)
- ML20070P481 + (14:18:04, 16 December 2024)
- 05000423/LER-1990-001, :on 910108,inoperable Fire Hose Stations Due to Insufficient Fire Hose Inventory.Cause Unknown for Fuel Bldg Fire Hose Rack & Procedural Inadequacy for Auxiliary Bldg Fuel Racks.Station Restored to Operable Status + (14:18:06, 16 December 2024)
- 05000317/LER-1982-079-03, /03L-0:on 821209,due to Loading of Main Turbine Generator & on 821229,during Normal Shutdown Operation, Pressurizer Level Deviated from Program Band.Rcs Temp Swing Not Uncommon During Shutdown Operations + (14:18:08, 16 December 2024)
- ML20070P472 + (14:18:09, 16 December 2024)
- ML20070P466 + (14:18:09, 16 December 2024)
- 05000317/LER-1982-079, Forwards LER 82-079/03L-0 + (14:18:10, 16 December 2024)
- ML20070P444 + (14:18:10, 16 December 2024)
- ML20070P437 + (14:18:11, 16 December 2024)
- 05000456/LER-1994-007-02, :on 940407,SG Tube Found Degraded Due to Axial Outer Diameter Stress Corrosion Cracking.Corrective Actions: Implemented Programs to Mitigate Corrosive Environment in Tube Support + (14:18:13, 16 December 2024)
- ML20070P429 + (14:18:14, 16 December 2024)
- 05000457/LER-1994-004-07, :on 940406,control Rod K2 Failed to Fully Insert During Trip & Remained Out of Core at Indicated 210 Steps Due to Procedural Deficiency.Corrective Action: Shutdown Margin Calculations Were Performed + (14:18:16, 16 December 2024)
- ML20070P424 + (14:18:17, 16 December 2024)
- ML20070P420 + (14:18:17, 16 December 2024)
- 1CAN039102, Withdraws Relief Request 31 Re Performance of Exercise & Stroke Time Testing for Decay Heat Cooler Bypass Valves CV-1432 & CV-1433 During Each Refueling Outage.Procedures Will Be Revised to Perform Testing During ASME Frequency + (14:18:18, 16 December 2024)
- ST-HL-AE-3723, Forwards South Texas Project Unit 1,Cycle 4 Core Operating Limits Rept, Rev 0 + (14:18:18, 16 December 2024)
- 05000327/LER-1991-003, :on 910218,centrifugal Charging Pump Declared Inoperable & Removed from Svc Due to Pump Degradation.Caused by Heavy Wear on Impeller Shoulders in Wear Ring Area.Pump Rotating Element Replaced + (14:18:20, 16 December 2024)
- BECO-91-040, Forwards Summary of Compliance W/Reg Guide 1.97,Rev 2 to Assist NRC in Review of Compliance W/Reg Guide 1.97,Rev 3, Per 9100115 & 0405 Ltrs + (14:18:25, 16 December 2024)
- 05000293/LER-1982-057-03, /03L-0:on 821213,during Routine Startup from Outage,Outboard MSIV AO 203-2C Did Not Close within Tech Spec Limit.Caused by Malfunctioning four-way Control Valve. Valve Replaced.Timing Dash Pot Adjusted + (14:18:27, 16 December 2024)
- ML20070P396 + (14:18:28, 16 December 2024)
- ML20070P394 + (14:18:28, 16 December 2024)
- ML20070P390 + (14:18:34, 16 December 2024)
- ML20070P388 + (14:18:36, 16 December 2024)