Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20071B783 + (11:59:11, 15 December 2024)
- ML20071B782 + (11:59:11, 15 December 2024)
- ML20071B778 + (11:59:12, 15 December 2024)
- ML20071B775 + (11:59:12, 15 December 2024)
- ML20071B774 + (11:59:13, 15 December 2024)
- ML20071B770 + (11:59:14, 15 December 2024)
- ML20071B769 + (11:59:14, 15 December 2024)
- ML20071B768 + (11:59:15, 15 December 2024)
- ML20071B766 + (11:59:15, 15 December 2024)
- ENS 56898 + (12:20:05, 16 December 2024)
- ENS 57457 + (12:20:06, 16 December 2024)
- ENS 57460 + (12:20:07, 16 December 2024)
- ENS 57470 + (12:20:08, 16 December 2024)
- ML20071B762 + (13:44:18, 16 December 2024)
- ML20071B761 + (13:44:19, 16 December 2024)
- ML20071B760 + (13:44:20, 16 December 2024)
- ML20071B755 + (13:44:21, 16 December 2024)
- ML20071B722 + (13:44:22, 16 December 2024)
- ML20071B719 + (13:44:23, 16 December 2024)
- ML20071B718 + (13:44:24, 16 December 2024)
- PLA-1514, Forwards Annual Personnel Exposure Rept for CY82 Reflecting Activities Both Before & After 820717 Receipt of OL + (13:44:25, 16 December 2024)
- 05000316/LER-1982-093-03, Following Unit Shutdown, RCS Dose Equivalent I-131 Concentration Exceeded Tech Spec Limit.Cause Not Stated.Fuel Shipping Performed During Refueling Outage to Identify Potential Leaking Assemblies + (13:44:30, 16 December 2024)
- ML20071B701 + (13:44:31, 16 December 2024)
- 05000316/LER-1982-093, Forwards Updated LER 82-093/03X-1 + (13:44:32, 16 December 2024)
- ML20071B692 + (13:44:32, 16 December 2024)
- 05000249/LER-1983-006-01, /01T-0:on 830208,LPCI Pump Suction Valve M03-1501-5D Failed Open.Caused by Auxiliary Contact CR 105X Failure in Control Circuitry of Valve.Contact Replaced + (13:44:35, 16 December 2024)
- ML20071B681 + (13:44:39, 16 December 2024)
- ML20071B680 + (13:44:40, 16 December 2024)
- ML20071B676 + (13:44:41, 16 December 2024)
- 05000324/LER-1983-008-03, /03L-0:on 830118,during Channel Calibr & Functional Test,Hpci Sys Condensate Storage Tank Low Level Instrument 2-E41-LSL-N003 Failed to Actuate within Required Tolerance.Caused by Debris in N003 Vent Line + (13:44:42, 16 December 2024)
- 05000373/LER-1983-004-03, /03L-0:on 830121,calibr of Hydrogen Recombiner Temp Instrumentation LIS-HG-01 Not Performed in Apr 1982. Caused by Surveillance Requirement Overlooked by Personnel. Requirements Reviewed + (13:44:45, 16 December 2024)
- 05000324/LER-1983-008, Forwards LER 83-008/03L-0 + (13:44:46, 16 December 2024)
- ML20071B667 + (13:44:47, 16 December 2024)
- ML20071B666 + (13:44:48, 16 December 2024)
- 05000373/LER-1983-004, Forwards LER 83-004/03L-0 + (13:44:48, 16 December 2024)
- 05000339/LER-1983-012-03, /03L-0:on 830114,delta T Indicator Associated W/Delta T Protection for Loop a Read 6% High.Caused by Failed Relay Card on Delta T Hot Loop A,TE-2412B,output. Card Replaced + (13:44:51, 16 December 2024)
- 05000249/LER-1983-005-01, /01T-0:on 830208,diesel Generator Failed to Start. Caused by Failure of Air Starter Motor Vanes to Engage. Ingersoll-Rand Air Starter Motors,Air Filter & Air Regulating Valve Replaced + (13:44:53, 16 December 2024)
- 05000339/LER-1983-012, Forwards LER 83-012/03L-0 + (13:44:54, 16 December 2024)
- ML20071B647 + (13:44:54, 16 December 2024)
- 05000259/LER-1983-004-03, /03L-0:on 830124,recirculation Pump 1A Increased Speed,Was Manually Tripped & Would Not Restart.Caused by Broken Heim Joint within Hydraulic Coupler Which Allowed Full Coupling of Motor & Generator.Joint Replaced + (13:44:56, 16 December 2024)
- ML20071B642 + (13:44:57, 16 December 2024)
- 05000259/LER-1983-004, Forwards LER 83-004/03L-0 + (13:44:58, 16 December 2024)
- 05000249/LER-1983-005, Forwards LER 83-005/01T-0 + (13:44:58, 16 December 2024)
- 05000328/LER-1983-006-03, /03L-0:on 830119,while in Mode 1,one Main Feedwater Flow Channel 2-FT-3-90A Failed High.Caused by Frozen Sense Line,Due to Incorrect Location of Heat Tracing Thermocouples.Thermocouples Relocated + (13:45:00, 16 December 2024)
- ML20071B626 + (13:45:01, 16 December 2024)
- 05000327/LER-1983-014-03, /03L-0:on 830122,kW Meter for Hydrogen Recombiner Read Offscale High.Caused by Failed Active Filter LZF1-271105 Due to Aging.Filter & Potentiometer Replaced + (13:45:03, 16 December 2024)
- 05000416/LER-1983-036-03, /03L-0:on 830124,heater Element in Steam Generator for Humidifier Section of Control Room Air Conditioning Sys B Train Found Arcing.Caused by Mineral Deposits from Makeup Water.Generator Cylinders Replaced + (13:45:08, 16 December 2024)
- 05000328/LER-1983-006, Forwards LER 83-006/03L-0 + (13:45:09, 16 December 2024)
- 05000416/LER-1983-036, Forwards LER 83-036/03L-0 + (13:45:10, 16 December 2024)
- 05000327/LER-1983-014, Forwards LER 83-014/03L-0 + (13:45:11, 16 December 2024)
- 05000416/LER-1983-016-03, /03L-0:on 830124,during Cold Shutdown,Supervision Sys for fire-rate Door OC517 Alarmed & Would Not Reset W/ Door Closed.Door Declared Inoperable.Cause Unknown.Sys Declared Operational 1 Wk Later & Door Restored + (13:45:19, 16 December 2024)