Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20071C119 + (11:56:52, 15 December 2024)
- AECM-82-562, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/82-53.Corrective Actions:Util Believes No Violation Existed & 8 H Sample Collection Frequency Justified & Conservative + (11:56:53, 15 December 2024)
- ML20071C114 + (11:56:53, 15 December 2024)
- 05000244/LER-1983-009-03, /03L-0:on 830119,boric Acid Transfer Pump B Tripped Immediately After Start.Caused by Failed Control Power Fuses.Fuses Replaced + (11:56:55, 15 December 2024)
- AECM-83-019, Submits Corrected Copy of Response to NRC Ltr Re Violations Noted in IE Insp Rept 50-416/82-53.Corrective Actions: Automated Sample Gathering Sys Installed & Expected to Be Tested & Operational by 830201 + (11:56:56, 15 December 2024)
- 05000244/LER-1983-009, Forwards LER 83-009/03L-0 + (11:56:57, 15 December 2024)
- AECM-83-037, Informs That Discharge Basin Automated Sample Gathering Sys Failed to Operate Properly When Energized.Failed Sys Under Investigation.Operability Expected Prior to Next Reactor Criticality + (11:57:02, 15 December 2024)
- 05000244/LER-1983-007-03, /03L-0:on 830117,water Level in Pressurizer Dropped Below 12% Level.Caused by RCS Cooldown Following Trip.Level Returned to 19.5% within 15 Minutes + (11:57:03, 15 December 2024)
- 05000280/LER-1983-003-01, /01T-0:on 830209,MOV-SW-103A,B,C & D & MOV-SW-203A,C & D Failed to Open Upon Demand from Control Room.Caused by Corrosion on Motors of MOV-SW-103C & 203C & Torque Switch of 103B.Valves Repaired + (11:57:05, 15 December 2024)
- ML20071C087 + (11:57:06, 15 December 2024)
- 05000244/LER-1983-007, Forwards LER 83-007/03L-0 + (11:57:07, 15 December 2024)
- 05000280/LER-1983-003, Forwards LER 83-003/01T-0 + (11:57:09, 15 December 2024)
- ML20071C073 + (11:57:10, 15 December 2024)
- 05000271/LER-1983-004-03, /03L-0:on 830120,flowmeter on Containment Air Monitor Read Zero Due to Leakage Past Detector O-ring Seal Into Reactor Bldg.Cause Not determined.O-ring Reseated + (11:57:12, 15 December 2024)
- ML20071C066 + (11:57:13, 15 December 2024)
- ML20071C060 + (11:57:14, 15 December 2024)
- ML20071C059 + (11:57:14, 15 December 2024)
- 05000271/LER-1983-004, Forwards LER 83-004/03L-0 + (11:57:15, 15 December 2024)
- 05000338/LER-1983-004-03, /03L-0:on 830125,svc Water Supply Valves MOV-SW- 103B & C & Discharge Valve MOV-SW-104C to Recirculation Spray HXs Would Not Open.Caused by Problems in Valve Operators.Valves Removed & Cleaned + (11:57:17, 15 December 2024)
- 05000338/LER-1983-004, Forwards LER 83-004/03L-0 + (11:57:19, 15 December 2024)
- ML20071C048 + (11:57:19, 15 December 2024)
- ML20071C039 + (11:57:20, 15 December 2024)
- ML20071C035 + (11:57:20, 15 December 2024)
- ML20071C034 + (11:57:21, 15 December 2024)
- ML20071C025 + (11:57:22, 15 December 2024)
- ML20071C031 + (11:57:22, 15 December 2024)
- 1CAN028305, Discusses Understanding Re 821210 Order for Mod to OL Concerning Inadequate Core Cooling,Per 830127 Meeting W/Nrc. Util 830117 Request for Extension of Deadline for Hearing Requests Will Be Withdrawn.Nrc Confirmation Requested + (11:57:23, 15 December 2024)
- ML20071C024 + (11:57:23, 15 December 2024)
- 0CAN028301, Application for Amend to Licenses DPR-51 & NPF-6,revising Tech Specs to Change in-core Detector Surveillance Requirements & to Correct Various Typographical,Title & Ref Errors + (11:57:24, 15 December 2024)
- ML20071C020 + (11:57:24, 15 December 2024)
- ML20071C010 + (11:57:25, 15 December 2024)
- ML20071C009 + (11:57:26, 15 December 2024)
- ML20071C008 + (11:57:26, 15 December 2024)
- ML20071C007 + (11:57:27, 15 December 2024)
- ML20071C003 + (11:57:27, 15 December 2024)
- 05000324/LER-1983-010, Forwards LER 83-010/03L-0 + (11:57:35, 15 December 2024)
- ML20071B998 + (11:57:35, 15 December 2024)
- ML20071B991 + (11:57:43, 15 December 2024)
- 05000318/LER-1983-006, Forwards LER 83-006/03L-0 + (11:57:44, 15 December 2024)
- 05000325/LER-1983-010-03, /03L-0:on 830120,routine Surveillance Revealed Water Leaking Into Reactor Bldg at 17-ft Elevation Via Secondary Containment Penetration/Fire Barrier Seal R1-1-049.Caused by Degradation Due to Exposure to Rainwater + (11:57:51, 15 December 2024)
- 05000325/LER-1983-010, Forwards LER 83-010/03L-0 + (11:57:52, 15 December 2024)
- 05000325/LER-1983-005-03, /03L-0:on 830119,during Normal Operation,Measured Specific Gravity of Pilot Cell for Div I Battery 1A-1 Was 1.166 & 1.167 for Div II Battery 1B-1.Caused by Age of Pilot Cells.Cells Replaced.Batteries Returned to Svc + (11:57:53, 15 December 2024)
- 05000325/LER-1983-005, Forwards LER 83-005/03L-0 + (11:57:54, 15 December 2024)
- 05000244/LER-1983-005-03, /03L-0:on 830117,I-131 Spike Occurred in RCS After Unit Tripped from 100% Power.Caused Not stated.I-131 Concentration Returned to Normal Levels by Normal Letdown + (11:57:56, 15 December 2024)
- 05000244/LER-1983-005, Forwards LER 83-005/03L-0 + (11:57:57, 15 December 2024)
- ML20071B974 + (11:57:57, 15 December 2024)
- ML20071B965 + (11:57:58, 15 December 2024)
- 05000416/LER-1983-027-99, /99X-0:on 830128,fire Door 1A215 Alarmed on Supervision Sys & Would Not Reset,Yet Verified Closed.Caused by Door Position Switch Out of Adjustment.Fire Watch Established.Switch Adjusted.Door Returned to Svc on 830201 + (11:57:59, 15 December 2024)
- A02905, Provides Results of Ongoing Study of Merits of Not Tripping Diesel Generators Upon Restoration of 125-volt Dc Electrical Power,Per Agreement Reached on IE Insp Rept 50-336/82-33. Listed Mods to Be Incorporated by End of 1983 + (11:58:00, 15 December 2024)
- 05000416/LER-1983-027, Forwards LER 83-027/99X-0 + (11:58:01, 15 December 2024)
- ML20071B960 + (11:58:01, 15 December 2024)
- ML20071B957 + (11:58:02, 15 December 2024)