- 05000302/LER-1983-011-03, /03L-0:on 830305,during Normal Operation,Two Holes Discovered in safety-related Fire Wall.Addl Investigation Revealed Two More Holes.Caused by Inadequate Mod Process.Mod Process Will Be Revised + (09:13:32, 15 December 2024)
- ML20072U510 + (09:13:33, 15 December 2024)
- ML20072U506 + (09:13:34, 15 December 2024)
- ML20072U505 + (09:13:36, 15 December 2024)
- 05000387/LER-1983-039-03, /03L-0:on 830225,during Review of Tech Spec, Channel Functional Tests for Rod Block Monitor & Recirculation Flow Units Omitted Prior to Startup.Caused by Procedures Not Being Placed in Tech Spec.Tech Spec Revised + (09:13:37, 15 December 2024)
- ML20072U496 + (09:13:38, 15 December 2024)
- 05000302/LER-1983-011, Forwards LER 83-011/03L-0 + (09:13:39, 15 December 2024)
- JAFP-83-0345, Forwards Radiological Environ Surveillance Rept,1982 + (09:13:40, 15 December 2024)
- ML20072U490 + (09:13:40, 15 December 2024)
- ML20072U475 + (09:13:41, 15 December 2024)
- PY-CEI-NRR-1857, Special Rept:On 940825,offgas Ventilation Exhaust Post Accident RM Declared Inoperable & Exceeded 72 H Limit on 940828 When New Flow Control Circuit Card Would Not Calibr Properly.Original Circuit Card Reinstalled & Calibr + (09:13:41, 15 December 2024)
- ML20072U471 + (09:13:42, 15 December 2024)
- AECM-83-0207, Forwards Application to Amend License NPF-13.Amend Revises Surveillance Procedure Review - Package 2 & Miscellaneous Tech Specs Re Responsibility for Auditing Station Activities + (09:13:43, 15 December 2024)
- ML20072U466 + (09:13:43, 15 December 2024)
- ML20072U462 + (09:13:44, 15 December 2024)
- 05000325/LER-1983-015-01, /01T-0:on 830318,five Suppression Sprinkler & Deluge Sys Surveillance Revealed Closed Well Water Isolation Valve to Standby Gas Treatment Sys Deluge Sys.Caused by Intentional Closing of Valve V207.Fire Watch Established + (09:13:46, 15 December 2024)
- ML20072U457 + (09:13:47, 15 December 2024)
- ML20072U454 + (09:13:47, 15 December 2024)
- ML20072U451 + (09:13:48, 15 December 2024)
- ML20072U449 + (09:13:49, 15 December 2024)
- ML20072U447 + (09:13:50, 15 December 2024)
- ML20072U441 + (09:13:50, 15 December 2024)
- ML20072U439 + (09:13:51, 15 December 2024)
- ML20072U438 + (09:13:51, 15 December 2024)
- ML20072U437 + (09:13:52, 15 December 2024)
- ML20072U436 + (09:13:53, 15 December 2024)
- 05000387/LER-1983-039, Forwards LER 83-039/03L-0 + (09:13:56, 15 December 2024)
- ML20072U431 + (09:13:56, 15 December 2024)
- ML20072U428 + (09:13:57, 15 December 2024)
- ML20072U423 + (09:13:57, 15 December 2024)
- ML20072U421 + (09:13:58, 15 December 2024)
- 05000387/LER-1983-035, Forwards LER 83-035/03L-0 + (09:13:59, 15 December 2024)
- ML20072U415 + (09:14:00, 15 December 2024)
- ML20072U411 + (09:14:01, 15 December 2024)
- ML20072U413 + (09:14:01, 15 December 2024)
- ML20072U407 + (09:14:02, 15 December 2024)
- ML20072U403 + (09:14:05, 15 December 2024)
- ML20072U400 + (09:14:05, 15 December 2024)
- 05000325/LER-1983-015, Forwards LER 83-015/01T-0 + (09:14:07, 15 December 2024)
- ML20072U394 + (09:14:07, 15 December 2024)
- BSEP-83-1083, Ro:During Refueling Outage,Fire Barrier Limiting Conditions for Operation 1-82-110 Generated to Permit Installation of Mod on Svc Water Sys Screen Pump 1A.Due to Complexity of work,7-day Time Frame Exceeded + (09:14:08, 15 December 2024)
- ML20072U390 + (09:14:09, 15 December 2024)
- ML20072U386 + (09:14:10, 15 December 2024)
- ML20072U385 + (09:14:10, 15 December 2024)
- B13801, Forwards Revised Tech Spec Pages Re Surveillance Requirements for Spec 4.0.2 Per Amend 151 to License DPR-65,in Response to NRC 910308 Request + (09:14:11, 15 December 2024)
- ML20072U384 + (09:14:11, 15 December 2024)
- ML20072U375 + (09:14:12, 15 December 2024)
- 05000373/LER-1983-019-03, /03L-0:on 830302,lake Blowdown Flow Recorder Gave Incorrect Readings.Caused by Instrument Probe Being Either Airbound or Plugged.Operating Surveillance Revised to Restrict Valve Position + (09:14:14, 15 December 2024)
- ML20072U365 + (09:14:17, 15 December 2024)
- 05000219/LER-1983-010-01, /01T-0:on 830307,design Deficiency Discovered When Standby Gas Treatment Sys (SGTS) II Racked Out for Maint. SGTS II Inlet & Outlet Valves Opened,Allowing Recirculation During Sys I Operation.Procedures Revised + (09:14:19, 15 December 2024)
- ML20072U362 + (09:14:20, 15 December 2024)
- ML20072U354 + (09:14:22, 15 December 2024)