Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20079N761 + (03:59:11, 15 December 2024)
- ML20079N757 + (03:59:11, 15 December 2024)
- 05000416/LER-1983-034, Forwards LER 83-034/03L-0 + (03:59:15, 15 December 2024)
- ML20079N752 + (03:59:16, 15 December 2024)
- ML20079N751 + (03:59:16, 15 December 2024)
- ML20079N749 + (03:59:17, 15 December 2024)
- ML20079N746 + (03:59:18, 15 December 2024)
- ML20079N735 + (03:59:19, 15 December 2024)
- 0CAN028322, Advises That Efforts Underway & Progress Being Made Toward Compliance w/820210 Order for Mod of License Re Detection of Inadequate Core Cooling.Response Expected by 830415 + (03:59:20, 15 December 2024)
- ML20079N732 + (03:59:20, 15 December 2024)
- ML20079N727 + (03:59:22, 15 December 2024)
- ML20079N723 + (03:59:23, 15 December 2024)
- 05000366/LER-1983-139-03, /03L-0:on 831214,position of Vacuum Breaker 2T48-F323C Could Not Be Confirmed Due to Blown Position Indicator Light Fuse 2T48-F1.Caused by Shorted Valve Position Switch.Switch & Fuse Replaced + (03:59:24, 15 December 2024)
- ML20079N711 + (03:59:25, 15 December 2024)
- ML20079N701 + (03:59:48, 15 December 2024)
- W3P84-0213, Requests Review of Encl Safety Info Booklet.Distribution to Public Scheduled for Early Mar 1984.W/two Oversize Charts. Aperture Cards Are Available in PDR + (03:59:48, 15 December 2024)
- 05000334/LER-1983-007-04, /04T-0:on 830214,tritium Activity in Fourth Quarter 1982 Composite of Weekly Grab Samples Collected in Oh River Downstream of Effluent Found to Be Above ETS Limits.Amend to ETS Submitted to Increase Acceptable Limit + (03:59:50, 15 December 2024)
- 05000348/LER-1983-065-03, /03L-0:on 831227,instrumentation Channel Associated W/Temp Indicator TI-432D Declared Inoperable. Caused by Drift of Lead/Lag Card Gain.Card Replaced & Channel Declared Operable + (03:59:52, 15 December 2024)
- 05000296/LER-1983-007, Forwards LER 83-007/03L-0 + (03:59:53, 15 December 2024)
- ML20079N688 + (03:59:54, 15 December 2024)
- 05000324/LER-1983-015-03, /03L-0:on 830123,reactor Recirculation Pump 2A Tripped.Caused by ATWS Reactor Pressure Instrument 2-B21-PS-NO45C Actuation Below Tech Spec Limit.Instrument Replaced + (03:59:56, 15 December 2024)
- ML20079N681 + (03:59:57, 15 December 2024)
- ML20079N685 + (03:59:57, 15 December 2024)
- 05000348/LER-1983-092-03, /03L-0:on 831225,instrumentation Channel Associated W/Pressure Transmitter PT-494 Declared Inoperable.Caused by Localized Freezing in Sensing Lines Due to Cold Weather.Lines Thawed Out + (04:00:04, 15 December 2024)
- 05000334/LER-1983-007, Forwards LER 83-007/04T-0 + (04:00:05, 15 December 2024)
- 05000296/LER-1983-006, Forwards LER 83-006/03L-0 + (04:00:06, 15 December 2024)
- 05000348/LER-1983-091-03, /03L-0:on 831226,radiation Monitor R-5 Declared Inoperable Due to Erroneous Indication.Caused by Faulty Connection.Connection Repaired & Monitor Declared Operable + (04:00:07, 15 December 2024)
- ML20079N668 + (04:00:08, 15 December 2024)
- 05000348/LER-1983-090-03, /03L-0:on 831224,radiation Monitors R-11 & R12 Declared Inoperable When Vacuum Pump Tripped.Caused by Flow Rate Set Too High.Method for Adjusting Flow Rate Revised & Monitors Returned to Svc + (04:00:10, 15 December 2024)
- IR 05000397/1983003 + (04:00:12, 15 December 2024)
- 05000324/LER-1983-015, Forwards LER 83-015/03L-0 + (04:00:13, 15 December 2024)
- ML20079N645 + (04:00:14, 15 December 2024)
- 05000416/LER-1983-040-03, /03L-0:on 830127,smoke Detector in Zone Covering Elevation 139 Ft in Auxiliary Bldg Covered to Perform Welding in Area & Prevent Actuation of Alarm.Caused by Planned Maint Activities.Smoke Detector Uncovered + (04:00:15, 15 December 2024)
- 05000416/LER-1983-090-01, Inlet Valve to Reactor Water Cleanup Sys Nonregenerative HX Discovered Closed. Caused by Valve Isolation When Relay Removed During Limiting Safety Sys Setting Troubleshooting + (04:00:17, 15 December 2024)
- 05000416/LER-1983-040, Forwards LER 83-040/03L-0 + (04:00:18, 15 December 2024)
- 05000237/LER-1983-083-03, /03L-0:on 831226,while Lowering Suppression Pool Level,Lpci 1501-3B Valve Tripped Thermally.Caused by Underrated Overload Heaters (GE CR 123 L1.74A) in Valve Motor Overload Assembly.Heaters Replaced + (04:00:20, 15 December 2024)
- ML20079N613 + (04:00:21, 15 December 2024)
- ML20079N610 + (04:00:21, 15 December 2024)
- ML20079N609 + (04:00:22, 15 December 2024)
- ML20079N603 + (04:00:23, 15 December 2024)
- ML20079N601 + (04:00:23, 15 December 2024)
- 0CAN028316, Application for Amend to Licenses DPR-51 & NPF-6,changing Tech Specs Section 6 to Require Annual Reporting of Safety & Relief Valve Challenges,In Response to NRC 820920 Generic Ltr 82-16 + (04:00:24, 15 December 2024)
- ML20079N595 + (04:00:24, 15 December 2024)
- ML20079N593 + (04:00:25, 15 December 2024)
- ML20079N590 + (04:00:26, 15 December 2024)
- A830027, Forwards Public Version of Rev 2 to Emergency Plan Implementing Procedure 5.7.2, Notification of Unusual Event. W/O Encl + (04:00:27, 15 December 2024)
- ML20079N582 + (04:00:28, 15 December 2024)
- 05000348/LER-1983-007-03, /03L-0:on 830114,electrical Penetration Q1T52B038-B Failed Local Leak Rate Test.Caused by O-ring Damage at Inner Seal from Repairs During Previous Refueling outage.O-rings Replaced + (04:00:29, 15 December 2024)
- 2CAN028316, Responds to Re Schedule for Core Protection Computer Mods to Correct Low Power Density Penalty Factor.Correction Will Be Provided During Next Software Update.Schedule Should Be Available by 830530 + (04:00:30, 15 December 2024)
- 05000321/LER-1983-113-03, /03L-0:on 831220,surveillance Personnel Noted Reactor Bldg Exhaust Vent Radiation Monitors 1D11-K609 A,B & C Inoperable.Caused by Monitors 1D11-K609 A,B & C Out of Calibr.Monitors Recalibr + (04:00:32, 15 December 2024)
- 05000348/LER-1983-007, Forwards LER 83-007/03L-0 + (04:00:33, 15 December 2024)