- ML20082R194 + (11:30:36, 14 December 2024)
- ML20082R193 + (11:30:39, 14 December 2024)
- PY-CEI-NRR-1948, Annual Radioactive Effluent Release Rept 1994:Quarter 1-4 + (11:30:40, 14 December 2024)
- 05000333/LER-1983-057-03, /03L-0:on 831106,during Surveillance Test, Calculation of Reactor Coolant Leakage Rates Inside Primary Containment Not Performed.Caused by Personnel Error.Missing Data Recorded & Personnel Counseled + (11:30:42, 14 December 2024)
- ML20082R177 + (11:30:43, 14 December 2024)
- 05000313/LER-1995-004-01, :on 950403,vendor Personnel Error in Programming Upgraded MFP Turbine Controller Resulted in Manual RT & Automatic Efs Actuation.Corrected Programming Errors + (11:30:45, 14 December 2024)
- ML20082R168 + (11:30:46, 14 December 2024)
- 05000293/LER-1995-004, :on 950324,drywell-to-torus Portion of Primary Containment Vaccuum Relief Sys Actuated While de-inerting Drywell.Caused by Deficiency in Approved Procedure Being Used.Revised Procedure to Correct Deficiency + (11:30:48, 14 December 2024)
- ML20082R143 + (11:30:51, 14 December 2024)
- ML20082R151 + (11:30:51, 14 December 2024)
- TXX-4084, Forwards Info Re Survey of Facility Staffing + (11:30:52, 14 December 2024)
- ML20082R125 + (11:30:53, 14 December 2024)
- ML20082R119 + (11:30:54, 14 December 2024)
- 05000334/LER-1983-034-03, /03L-0:on 831026,480-volt GE Breaker for Quench Spray Pump 1B Could Not Be Exercised.Manual Handle for Breaker Disengaged from Closing Device.Caused by Excessive Force Used on Breaker + (11:30:55, 14 December 2024)
- ML20082R099 + (11:30:56, 14 December 2024)
- 05000302/LER-1983-049-03, /03L-0:on 831104,audit Revealed Lack of Surveillance Procedure to Examine Sensors During Channel Calibr.Caused by Procedural Inadequacy.Surveillance Procedure SP-161 Revised Prior to Next Calibr + (11:30:58, 14 December 2024)
- 05000331/LER-1991-009, :on 910815,reactor Water Cleanup Sys Isolation Occurred.Caused by Blown Fuse in Power Supply Unit Resulting in Square Root Converter to Lose Power.Clip Repositioned & Fuse Replaced + (11:31:00, 14 December 2024)
- ML20082R076 + (11:31:01, 14 December 2024)
- 05000277/LER-1991-029, :on 910824,half Scram Occurred When B RPS Motor Generator Set Output Breaker Tripped.Caused by Broken Wire Inside Rheostat & Less than Adequate Rheostat Installation.Rheostat Replaced + (11:31:02, 14 December 2024)
- ML20082R071 + (11:31:03, 14 December 2024)
- ML20082R057 + (11:31:05, 14 December 2024)
- 05000416/LER-1991-010-02, :on 910810,lightning Induced Spike Occurred Causing APRM Scram.Caused by High Flux Signal on 4 of 8 APRM Channels.Expansion of Site Lightning Protection Will Be Completed Prior to Startup from Outage 5 + (11:31:06, 14 December 2024)
- 05000423/LER-1991-019-02, :on 910725,plant Shutdown Initiated After Train B of Svc Water Declared Inoperable & Train B Could Not Be Restored within 72 H.Caused by Design Deficiency.Piping Cleaned & Will Be Flushed + (11:31:09, 14 December 2024)
- 05000416/LER-1983-175-03, /03L-0:on 831028 & 31,Div II Diesel Generator Tripped Due to High Vibration Signal.Caused by Too Sensitive Setpoint.Setpoint Corrected & Instrument Recalibr + (11:31:10, 14 December 2024)
- ML20082R014 + (11:31:11, 14 December 2024)
- 05000321/LER-1991-014-01, :on 910810,component Failure Occurred Resulting in Unplanned ESF Actuations.Failed Components Replaced, Operating Order Issued & Design & Field Review of SGTS Actuation Logic Completed + (11:31:13, 14 December 2024)
- 05000423/LER-1991-021-01, :on 910728,containment Isolation Valve Found Locked Closed & Open.Caused by Improper Task Verification. Valve Opened & Instructions Re Tracking Valve Will Be Incorporated Into Training Program + (11:31:15, 14 December 2024)
- ML20082Q998 + (11:31:16, 14 December 2024)
- ML20082Q993 + (11:31:17, 14 December 2024)
- ML20082Q978 + (11:31:18, 14 December 2024)
- ML20082Q991 + (11:31:18, 14 December 2024)
- ML20082Q951 + (11:31:19, 14 December 2024)
- 0CAN099106, Forwards Proposed Rev to Industrial Security Plan Due to Security Perimeter Improvement Project at Facilities & Minor Revs to 910522 Proposed Change to Industrial Security Plan.Encls Withheld (Ref 10CFR73.21) + (11:31:20, 14 December 2024)
- ML20082Q949 + (11:31:20, 14 December 2024)
- ML20082Q947 + (11:31:21, 14 December 2024)
- GO2-91-161, Forwards Rev 20 to Physical Security Plan.Rev Withheld (Ref 10CFR73.21) + (11:31:22, 14 December 2024)
- ML20082Q941 + (11:31:22, 14 December 2024)
- GO2-91-162, Forwards Rev 10 to Safeguards Contingency Plan.Rev Withheld (Ref 10CFR73.21) + (11:31:23, 14 December 2024)
- ML20082Q925 + (11:31:24, 14 December 2024)
- ML20082Q927 + (11:31:24, 14 December 2024)
- ML20082Q912 + (11:31:25, 14 December 2024)
- ML20082Q900 + (11:31:26, 14 December 2024)
- ML20082Q893 + (11:31:27, 14 December 2024)
- RBG-41242, Submits Rev to Plant Commitments Re Very High Radiation Area Issues + (11:31:27, 14 December 2024)
- ML20082Q878 + (11:31:28, 14 December 2024)
- JPN-91-047, Forwards Status Rept on 18 Tasks Committed to by Util to Complete Response to Generic Ltr 88-14, Instrument Air Supply Problems Affecting Safety-Related Equipment. Only 4 of 18 Tasks Remain to Be Completed + (11:31:30, 14 December 2024)
- ML20082Q876 + (11:31:30, 14 December 2024)
- ML20082Q864 + (11:31:31, 14 December 2024)
- BSEP-95-0171, Radiological Environ Operating Rept,1994, Vols I,Ii & III + (11:31:32, 14 December 2024)
- ML20082Q862 + (11:31:32, 14 December 2024)
- ML20082Q838 + (11:31:33, 14 December 2024)