- 05000317/LER-1995-001-01, :on 950415,Unit 1 Entered TS 3.0.3 When EDG Supplying Backup Power Became Inoperable.Caused by Leaking Fuel Injector Pump Due to Improper Drainage.Drain Lines Cleaned + (10:21:56, 14 December 2024)
- AECM-84-0235, Forwards Rev 0 to Third Party Review of Grand Gulf Nuclear Station Tech Spec Review Program + (10:21:57, 14 December 2024)
- ML20083M844 + (10:21:57, 14 December 2024)
- NRC-95-4455, Provides W Updated Description of Milestones That Represent Resolution Path for AP600 Passive Sys Reliability + (10:21:58, 14 December 2024)
- ML20083M833 + (10:21:59, 14 December 2024)
- ML20083M831 + (10:22:00, 14 December 2024)
- AECM-83-0055, Suppl to 820809 Final Part 21 Rept for Potentially Reportable Deficiency Re Relay Failure in Div 1 Standby Diesel Generator.Magnecraft W88LCPX-12 Relay Will Be Replaced Since Sufficient Contacts Not Available for Mod + (10:22:01, 14 December 2024)
- NRC-84-0068, Forwards Proprietary & Nonproprietary Westinghouse Interconnecting Wiring Diagrams & Process Control Block Diagrams Associated W/Pressurizer Pressure Input.Proprietary Info Withheld (Ref 10CFR2.790) + (10:22:01, 14 December 2024)
- ML20083M819 + (10:22:02, 14 December 2024)
- ML20083M822 + (10:22:02, 14 December 2024)
- 1CAN059506, Documents Util Position Discussed on 950512 W/Nrc & Requests Enforcement Discretion from Specific Test Flow Requirement of TS 4.5.2.1.2(a)(1) to Allow Determining Proper Sys Operation by Engineering Evaluation in Bases of TS 3.3 + (10:22:03, 14 December 2024)
- B11039, Forwards Spent Fuel Disposition Plans, Outlining Program Undertaken to Increase Spent Fuel Storage Capacity + (10:22:04, 14 December 2024)
- ML20083M815 + (10:22:04, 14 December 2024)
- ML20083M814 + (10:22:05, 14 December 2024)
- ML20083M812 + (10:22:06, 14 December 2024)
- 05000335/LER-1982-068-03, /03L-0:on 821220,one of Four Redundant 120-volt Ac Instrument Power Buses Was Lost When 1A Static Inverter Output Breaker Opened.Cause Not Determined.Inverter Contacts Cleaned & Tested.Inverter Returned to Svc + (10:22:08, 14 December 2024)
- ML20083M806 + (10:22:09, 14 December 2024)
- ML20083M808 + (10:22:09, 14 December 2024)
- 3F0595-15, Annual Radiological Environ Operating Rept 1994 + (10:22:10, 14 December 2024)
- ML20083M805 + (10:22:10, 14 December 2024)
- 05000335/LER-1982-068, Forwards LER 82-068/03L-0 + (10:22:11, 14 December 2024)
- ML20083M792 + (10:22:12, 14 December 2024)
- ML20083M791 + (10:22:13, 14 December 2024)
- ML20083M783 + (10:22:13, 14 December 2024)
- ML20083M781 + (10:22:17, 14 December 2024)
- 05000324/LER-1982-143-03, /03L-0:on 821220,reactor Water Cleanup Differential Flow Indicator 2-G31-R615 Indicated Downscale During Routine Surveillance.Caused by Partially Plugged Low Side Sensing Line to FT-N041 & Out of Calibr Transmitters + (10:22:19, 14 December 2024)
- 05000324/LER-1982-143, Forwards LER 82-143/03L-0 + (10:22:20, 14 December 2024)
- ML20083M760 + (10:22:20, 14 December 2024)
- LD-83-005, Advises That Administrative Slippage in CESSAR-F Schedule Unwarranted & counterproductive.CESSAR-F Final Design Approval Should Be Issued by Mar 1983 + (10:22:21, 14 December 2024)
- ML20083M757 + (10:22:22, 14 December 2024)
- ML20083M753 + (10:22:25, 14 December 2024)
- 05000247/LER-1982-038-03, /03L-0:on 820901,during Normal Operation,Reactor Containment Fan Cooler Unit 24 Discovered Not Operating Properly.Caused by Loose Outboard Fan Bearing Resulting in Coupling Failure.Coupling Replaced + (10:22:26, 14 December 2024)
- ML20083M743 + (10:22:27, 14 December 2024)
- ML20083M749 + (10:22:27, 14 December 2024)
- ML20083M739 + (10:22:28, 14 December 2024)
- 05000247/LER-1982-038, Forwards LER 82-038/03L-0 + (10:22:29, 14 December 2024)
- ML20083M734 + (10:22:32, 14 December 2024)
- ML20083M733 + (10:22:33, 14 December 2024)
- ML20083M731 + (10:22:36, 14 December 2024)
- ML20083M730 + (10:22:37, 14 December 2024)
- ML20083M722 + (10:22:41, 14 December 2024)
- ML20083M727 + (10:22:41, 14 December 2024)
- ML20083M714 + (10:22:42, 14 December 2024)
- ML20083M712 + (10:22:43, 14 December 2024)
- 05000366/LER-1982-135-03, /03L-0:on 821228,north Wall of Control Room Air Lock Breached & Unattended During Performance of Control of Transient Combustibles.Caused by Personnel Error.Wall Repaired & Personnel Counseled + (10:22:44, 14 December 2024)
- 05000366/LER-1982-135, Forwards LER 82-135/03L-0 + (10:22:49, 14 December 2024)
- 05000416/LER-1982-177-03, /03L-0:on 821227,while Attempting to Start Control Room Air Conditioner B,Common Supply Breaker for Fan Compressor Tripped as Soon as Shut.Caused by Failed Trip Unit.Unit Replaced + (10:22:50, 14 December 2024)
- 05000416/LER-1982-177, Forwards LER 82-177/03L-0 + (10:22:52, 14 December 2024)
- 05000280/LER-1982-127-03, /03L-0:on 821228,while Gaseous Release in progress,RR-175 Indicated off-scale Process Vent Gaseous Radiation Monitor RM-GW-102.Caused by Failure of Discriminator Printed Circuit Board.Board Replaced + (10:22:53, 14 December 2024)
- 05000280/LER-1982-125-03, /03L-0:on 821221,w/unit at Full Power,Periodic Test 2.1 Revealed That Output of Loop a Delta T Summator Below Acceptable Limits.Caused by Instrument Drift.Summator Recalibr & Returned to Svc + (10:22:55, 14 December 2024)
- ML20083M679 + (10:22:59, 14 December 2024)
- ML20083M676 + (10:23:00, 14 December 2024)