- ML20085C289 + (08:49:32, 14 December 2024)
- ML20085C282 + (08:49:35, 14 December 2024)
- ML20085C271 + (08:49:36, 14 December 2024)
- ML20085C276 + (08:49:36, 14 December 2024)
- ML20085C261 + (08:49:39, 14 December 2024)
- 05000482/LER-1990-027, :on 910730,discovered That STS ML-001 Had Not Been Performed within Required Time Frame During Refueling Iv.Caused by Lack of Administrative Controls.Data Base Review Conducted + (08:49:40, 14 December 2024)
- ML20085C235 + (08:49:41, 14 December 2024)
- ML20085C223 + (08:49:42, 14 December 2024)
- ML20085C221 + (08:49:43, 14 December 2024)
- ML20085C218 + (08:49:43, 14 December 2024)
- 05000277/LER-1991-026, :on 910727,actuations Occurred on Primary Containment Isolation Sys When 4 Kv Emergency Bus Transferred to Startup Feed.Caused by Phase B Arcing. Isolations Reset & Disconnect Repaired + (08:49:48, 14 December 2024)
- 05000277/LER-1991-025, :on 910728,isolation of HPCI Sys Occurred During Performance of Surveillance Test,Resulting in ESF Actuation.Caused by Failure to Follow Procedures & Procedural Weaknesses.Procedures Revised + (08:49:50, 14 December 2024)
- ML20085C208 + (08:49:51, 14 December 2024)
- ML20085C204 + (08:49:52, 14 December 2024)
- ML20085C206 + (08:49:52, 14 December 2024)
- ML20085C199 + (08:49:53, 14 December 2024)
- ML20085C198 + (08:49:53, 14 December 2024)
- ML20085C187 + (08:49:54, 14 December 2024)
- L-91-231, Forwards Rev 12 to Training & Qualification Plan, Consisting of Summary of Changes & Marked Up Copy of Revised Pages & Direction for Incorporating Rev Into Plan + (08:49:55, 14 December 2024)
- ML20085C180 + (08:49:55, 14 December 2024)
- ML20085C172 + (08:49:56, 14 December 2024)
- 05000336/LER-1991-006, :on 910330,Surveillance Requirement Section 4.0.5 Re Inservice Insp of ASME Code Class 1,2 & 3 Components Not Performed within 92 Day Interval.Caused by Inadequate Planning.Schedule Enhanced + (08:49:58, 14 December 2024)
- ML20085C166 + (08:49:59, 14 December 2024)
- 05000266/LER-1991-009, :on 910727,runback of Unit 1 Turbine Generator Discovered Initiated.Cause Unknown.Flux Maps Monitored for Quadrant Power Tilt & Core Flux Mapping Initiated + (08:50:01, 14 December 2024)
- 05000413/LER-1991-010, :on 910526,feedwater Isolation Occurred.Cause for Event Unknown.Facility Will Evaluate Need to Replace Westinghouse W-2 Cell Switch Which Had Sensitivity Problems in Past + (08:50:03, 14 December 2024)
- 05000265/LER-1991-008-04, :on 910723,outboard Recirculation Sample Valve AO-2-220-45 Closed W/No Apparent Signal.Caused by Defective Connections in Control Circuitry.Corrective Actions Included Fuse Verfication & Insp of All Terminations + (08:50:05, 14 December 2024)
- 05000325/LER-1991-019, :on 910723,maint Surveillance Test Procedures Found to Be Revised Incorrectly.Caused by Lack of Formal Process for Ensuring That Procedure Was Electronically Altered Via Word Processing.Procedure Revised + (08:50:07, 14 December 2024)
- 05000259/LER-1991-008-02, :on 910724,fire Wrap Discovered Removed During Unit 3 Integrated Walkdown Activities W/O Establishing Fire Watch.Caused by Mgt Failure.Duties,Responsibilities & Accountabilities for Field Svcs Developed + (08:50:09, 14 December 2024)
- ML20085C152 + (08:50:10, 14 December 2024)
- ML20085C148 + (08:50:11, 14 December 2024)
- ML20085C144 + (08:50:12, 14 December 2024)
- ML20085C139 + (08:50:13, 14 December 2024)
- 05000445/LER-1991-021, :on 910728,ESF Actuation Occurred.Caused by Lightning Strike.Design Mod to Switchyard to Enhance Reliability of Offsite Power Sources Partially Completed + (08:50:15, 14 December 2024)
- 05000499/LER-1991-009-02, :on 910707,ESF Actuation Occurred.Caused by Failed Light Emitting Diode.Engineering Review Conducted Determining Generic Problem Exists W/Leds Used in Sequencer Circuits + (08:50:20, 14 December 2024)
- 05000333/LER-1991-012, :on 910721,south Cable Tunnel to Relay Room Fire Door Found Blocked Open During Shutdown for Maint. Caused by Human Error.South Cable Door Closed & Addl Fire Watch Posted + (08:50:22, 14 December 2024)
- 05000354/LER-1991-016-01, :on 910724,ESF Actuation Occurred Re RCIC Sys Isolation.Caused by Instrument Failure.Failed Card in Numac Monitor Replaced & Sys Returned to Operable Status + (08:50:24, 14 December 2024)
- 05000354/LER-1990-029, :on 901126,ECCS Actuation Occurred Re Electrical Spike on Channel a Logic Results in Autostart of Channel A.Caused by Inadequate Design.Nuclear Training Dept Incorporated Review of Event + (08:50:27, 14 December 2024)
- 05000369/LER-1991-011-02, :on 910724,fuel Discovered Moved in Fuel Pool While Fuel Handling Exhaust Sys Inoperable.Caused by Inappropriate Actions.Personnel Involved Reviewed Event + (08:50:32, 14 December 2024)
- 05000327/LER-1991-018, :on 910812,fire Barriers Discovered Not to Comply W/Underwriters Lab Configurations Resulting in Deterioration of Matl.Caused by Listed Inadequacies.Fire Barriers Inspected + (08:50:34, 14 December 2024)
- 05000325/LER-1991-020, :on 910725,HPCI Steam Supply Line Being Placed in Standby Lineup.Caused by Possibility of Small Pressure Switches.Hpci Low Pressure Isolation Switches Immediately Reset + (08:50:36, 14 December 2024)
- 05000353/LER-1991-012, :on 910627,two Floor Drain Plugs Associated W/Reactor Enclosure (Re) Secondary Containment (Sc) Removed, Rendering Re Sc Inoperable.Caused by Personnel Error. Corrective Actions Included Counseling + (08:50:38, 14 December 2024)
- ML20085C088 + (08:50:39, 14 December 2024)
- ML20085C081 + (08:50:40, 14 December 2024)
- ML20085C060 + (08:50:41, 14 December 2024)
- ML20085C057 + (08:50:42, 14 December 2024)
- ML20085B981 + (08:50:43, 14 December 2024)
- ML20085B966 + (08:50:43, 14 December 2024)
- ML20085B933 + (08:50:44, 14 December 2024)
- ML20085B956 + (08:50:44, 14 December 2024)
- ML20085B926 + (08:50:45, 14 December 2024)
- ML20085B919 + (08:50:46, 14 December 2024)