- ML11290A102 + (06:33:23, 13 January 2025)
- ML11290A103 + (06:33:23, 13 January 2025)
- ML11290A100 + (06:33:24, 13 January 2025)
- ML11290A079 + (06:33:25, 13 January 2025)
- ML11290A098 + (06:33:25, 13 January 2025)
- ML11290A078 + (06:33:26, 13 January 2025)
- ML11290A077 + (06:33:27, 13 January 2025)
- ML11290A072 + (06:33:28, 13 January 2025)
- L-2011-404, Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request + (06:33:29, 13 January 2025)
- ML11290A041 + (06:33:29, 13 January 2025)
- W3F1-2011-0067, License Amendment Request, Proposed Change to Technical Specification 3/4.7.4 Table 3.7-3, Ultimate Heat Sink Minimum Fan Requirements Per Train + (06:33:30, 13 January 2025)
- ML11290A007 + (06:33:34, 13 January 2025)
- ML11290A006 + (06:33:35, 13 January 2025)
- ML112901416 + (06:33:36, 13 January 2025)
- ML112901415 + (06:33:37, 13 January 2025)
- ML112901413 + (06:33:38, 13 January 2025)
- ML112901412 + (06:33:39, 13 January 2025)
- ML112901411 + (06:33:40, 13 January 2025)
- ML112901409 + (06:33:41, 13 January 2025)
- ML112901408 + (06:33:42, 13 January 2025)
- ML112901387 + (06:33:46, 13 January 2025)
- 05000282/LER-2011-003, Regarding Unit 1 Reactor Coolant System Leak Detection Was Inoperable + (06:33:50, 13 January 2025)
- PNP 2011-071, Special Report of Inoperability of High Range Noble Gas Monitor + (06:33:51, 13 January 2025)
- ML112901115 + (06:33:52, 13 January 2025)
- 05000263/LER-1979-024-03, /03L-0:on 791220,during Normal Operation,Routine Operator Insp Revealed Steam Leak in 1-inch 90 Degree Elbow in Reactor Core Isolation Cooling Steam Line Drain to Condenser.Caused by Pinhole Failure of 3,000-lb Socket Weld + (06:33:55, 13 January 2025)
- 05000263/LER-1979-023, Updated LER 79-023/01T-1:on 800103,one Fuel Type Noted to Exceed Max Allowable Max Average Planar Linear Heat Generation Rate Value & Another as Improperly Programmed in Plant Computer.Caused by Inadequate Review + (06:33:57, 13 January 2025)
- 05000263/LER-1979-022-03, /03L-0:on 791213,during Normal Operation,Leak Discovered in 90-degree Elbow on 1-inch Condensate Line from Steam Supply to Recombiner Train Drain Trap.Caused by Erosion from Hot Steam Drains.Elbow Modified + (06:34:00, 13 January 2025)
- 05000263/LER-1979-021-03, /03L-0:on 791119,during IE Bulletin 79-02 Evaluation,Snubber SS-31 Base Plate Expansion Anchor Bolt Safety Factor Found to Be Less than One.Caused by Inadequate Base Plate & Expansion Anchor Bolts + (06:34:02, 13 January 2025)
- 05000263/LER-1979-019-03, /03L-0:on 790923,ECCS Yarway Level Switches Indicated Falsely High Level & Would Not Have Tripped within Specified Settings.Caused by Effects of Leak Which Developed in Reactor Pressure Gauge During Normal Operation + (06:34:05, 13 January 2025)
- 05000263/LER-1979-017-03, /03L-0:on 790806,steam Leak Observed on Feedwater Extraction Steam Line Drain 15A.Caused by Steam Erosion Through Wall of Steam Trap on Line.Trap Isolated Pending Repair or Replacement at Next Appropriate Outage + (06:34:07, 13 January 2025)
- 05000263/LER-1979-016-03, /03L-0 on 790731:turbine Tripped on Low Oil Pressure.Caused by Clogged Lube Oil Filter.Sys Drained, Inspected & Flushed + (06:34:09, 13 January 2025)
- ML112900892 + (06:34:10, 13 January 2025)
- 05000263/LER-1979-015-03, /03L-0 on 790712:discovered Steam Leak from Intermediate Pressure Feedwater Heater.Cause Undetermined. Temporary Patch Installed Pending Replacement of Heater Shell + (06:34:12, 13 January 2025)
- ML112900885 + (06:34:13, 13 January 2025)
- 05000263/LER-1979-013-03, /03L-0 on 790708:motor Operator Failed,Rendering Torus Cooling Injection Valve Inoperable During Normal Operation.Caused by Failure of Motor Winding Due to Limit Switch Not de-energizing Motor.Switch Replaced + (06:34:15, 13 January 2025)
- 05000263/LER-1979-014-03, /03L-0 on 790709:water Leak Discovered in 1/2 Inch Instrument Line from Reactor Water Cleanup Sys Nonregenerative Heat Exchanger.Cause Not Determined.Leaking Line Isolated & Will Be Further Investigated & Repaired + (06:34:17, 13 January 2025)
- 05000263/LER-1979-012-03, /03L-0 on 790702:during Reactor Core Isolation Cooling Sys Test,Governor end-bearing Temp Alarm Received & Bearing Exhibited High Vibration.Sys Inoperative.Caused by Turbine Oil Pump Drive Gear Failure.Gears Replaced + (06:34:20, 13 January 2025)
- 05000263/LER-1979-011-03, /03L-0 on 790529:no Min Flow in B Train Standby Gas Treatment Sys.Caused by Dilution Flow from Compressed Storage Not Isolated by BV-5.Replaced Positioner & Installed Filter in Cylinder Supply/Return Line + (06:34:22, 13 January 2025)
- 05000263/LER-1979-010-01, /01T-0 on 790426:informed by General Motors of Potential Diesel Generator Turbocharger Problem.Caused by Inadequate Design of Lube Oil Sys.Mod Being Developed + (06:34:25, 13 January 2025)
- 05000263/LER-1979-009-03, /03L-0 on 790404:steam Leak Found in 90 Degree Elbow in 1-inch Core Isolation Cooling Steam Supply Drain Pot Condenser Line.Caused by Erosion Due to High Velocity Steam from Leaking Valve.Hole Patched.Repairs Planned + (06:34:27, 13 January 2025)
- 05000263/LER-1979-020-03, /03L-0:on 791030,reactor Core Isolation Cooling Isolation Temp Switch Found to Trip Above Allowable Setpoint.Caused by Setpoint Drift.Switch Replaced + (06:34:29, 13 January 2025)
- 05000263/LER-1980-023-03, /03L-0:on 800601,air Ejector Offgas Radiation Monitors Dropped to About 20% Normal for About 40 Minutes. Caused by Mechanical Vacuum Pump Offgas Sample Valve Being Incorrectly Opened.Valve Now Wired Shut + (06:34:31, 13 January 2025)
- 05000263/LER-1980-022-03, /03L-0:on 800529,primary Containment Oxygen Concentration Exceeded 5% by Weight Tech Spec Limit.Caused by Open Svc Air Isolation Valve to Drywell.Procedures Have Been Revised to Assure Proper Valve Positioning + (06:34:33, 13 January 2025)
- 05000263/LER-1980-021-03, /03L-0:on 800515,during Normal Startup,Reactor Core Isolation Cooling Control Power Fuse Opened.Caused by Shorted Relay Coil in Circuit Due to Ac Relay Inadvertently Installed by Maint Personnel.Relay Replaced + (06:34:35, 13 January 2025)
- 05000263/LER-1980-020-03, /03L-0:on 800427,during post-maint Startup of Reactor Recirculation Sys,Inaccessible Recirculation Valve Motor Failed.Cause Not Stated.Motor Is Limitorque Type SMB-2 W/Magnetic Brake + (06:34:39, 13 January 2025)
- 05000263/LER-1980-018-03, /03L-0:on 800411,during Routine Operator Insp, Attachment Weld of Ripple to Level Switch Float Chamber Assembly on Moisture Separator Level Switch LS-1188 Found Cracked.Caused by Improper Weld Procedure + (06:34:41, 13 January 2025)
- 05000263/LER-1980-017-01, /01T-0:on 800328,Bechtel Power Corp Notified Util That Control Rod Driveline Hydraulic Piping Frame Supports Would Not Meet OBE Stress Limits.Caused by Eds Computer Code Error.Supports Modified + (06:34:43, 13 January 2025)
- 05000263/LER-1980-016-01, /01T-0:on 800327,during Refueling,Supports for SRV Pneumatic Supply Sys Would Not Meet Seismic Class I Requirements.Caused by Inadequate Design & Installation of Sys.Sys Was Upgraded to Satisfy Requirements + (06:34:45, 13 January 2025)
- 05000263/LER-1980-015-01, /01T-0:on 800317,during Refueling Outage & Insp Required by IE Bulletin 79-01B,unqualified Splices Found in Power Cables for Inboard MSIV Solenoid Valves.Cause Not Stated.Splices Replaced W/Qualified Matls + (06:34:48, 13 January 2025)
- 05000263/LER-1980-006-03, /03L-0:on 800226,during Refueling Outage,Seven of Main Steam Line Area Temp Switches Found to Trip Above Required Level.Caused by Setpoint Drift.Switches Recalibr + (06:34:50, 13 January 2025)
- 05000263/LER-1980-011-01, /01T-0:on 800306,during Refueling Outage,Repairs to Outboard MSIV Stop Valve Revealed Flow Path Between Secondary Containment & Turbine Bldg When MSIV Poppet Was Pulled.Caused by Lack of Preventive Procedure Controls + (06:34:58, 13 January 2025)