- ML13330A888 + (06:24:53, 11 January 2025)
- 05000206/LER-1980-011-43, /43Z-0:on 800310,while Purging Pressurizer Relief Tank to Remove Oxygen Tank,Disc Ruptured.Caused by Overfilliing W/Primary Makeup Water.Ruptured Disc Replaced + (06:24:56, 11 January 2025)
- 05000206/LER-1980-011, Forwards LER 80-011/43Z-0 + (06:25:01, 11 January 2025)
- 05000206/LER-1980-010-03, /03L-0:on 800318,during Full Power Operation,High Temp Indication Observed on South Charging Pump Thrust Bearing.Caused by Loose Coupling Hub on Pump Shaft.Damaged Inboard Bearing Shoes & Coupling Hubs Replaced + (06:25:05, 11 January 2025)
- 05000206/LER-1980-010, Forwards LER 80-010/03L-0 + (06:25:09, 11 January 2025)
- 05000206/LER-1980-008-03, /03L-0:on 800318,during Maint of Saltwater Cooling Pump,Pipe Support 9-416-4 & Concrete Anchors Found Corroded.Caused by Vibration & Corrosion Induced by Saltwater Environ.Support Redesigned & Built + (06:25:14, 11 January 2025)
- 05000206/LER-1980-008, Forwards LER 80-008/03L-0 + (06:25:17, 11 January 2025)
- ML13330A876 + (06:25:22, 11 January 2025)
- 05000206/LER-1980-006-01, /01T-0:on 800310,during Normal Operation,South Saltwater Cooling Pump Discharge Pressure Dropped Sharply, North Saltwater Pump Started,But Discharge POV Failed to Open.Caused by Vibration That Sheared South Pump + (06:25:25, 11 January 2025)
- 05000206/LER-1980-005-01, /01T-0:on 800218,during Operation on One Condenser Half,Seaweed Partially Blocked Flow of Inservice Condenser, Causing Differential Temp to Exceed 38F Limit.Heavy Storms Caused Increased Seaweed Inflow.Power Temporarily Redu + (06:25:31, 11 January 2025)
- 05000206/LER-1980-005, Forwards LER 80-005/01T-0 + (06:25:38, 11 January 2025)
- ML13330A870 + (06:25:40, 11 January 2025)
- 05000206/LER-1980-004-03, /03L-0:on 800119,during Normal Operation, Feedwater Flow Indication B Increased About 15% Above Actual Flow.Caused by Missing Segments in Flow Straightener Indicated by Radiograph.Straightener Was Replaced + (06:25:43, 11 January 2025)
- ML13330A864 + (06:25:45, 11 January 2025)
- 05000206/LER-1980-004, Forwards LER 80-004/03L-4 + (06:25:49, 11 January 2025)
- ML13330A862 + (06:25:51, 11 January 2025)
- BVY 13-101, Entergys Request for Rescission of and Schedule Relief from Commission Order Modifying License with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions (Order Number EA-13-109) + (06:25:53, 11 January 2025)
- ML13330A860 + (06:26:01, 11 January 2025)
- BVY 13-100, Response to Request for Additional Information Pursuant to 10 CFR 50.54(f) Regarding the Seismic Hazard Walkdowns Conducted to Verify Current Plant Compliance with the Current Licensing Basis (CLB) for Seismic Requirements + (06:26:02, 11 January 2025)
- ML13330A857 + (06:26:04, 11 January 2025)
- ML13330A856 + (06:26:05, 11 January 2025)
- 05000206/LER-1980-003-03, /03L-0:on 800109,during Normal Operations,While Performing Containment Isolation Valve Test CV-537,isolation Valve for Svc Water to Containment Failed to Close.Caused by Small Particles of Desiccant in Air Lines + (06:26:07, 11 January 2025)
- 05000206/LER-1980-003, Forwards LER 80-003/03L-0 + (06:26:11, 11 January 2025)
- 05000206/LER-1980-001-01, /01T-0:on 800110,during Field Verification Per IE Bulletin 79-14,found Supporting Configurations on Letdown Line & Turbine Plant Cooling Water Supply Line Not Installed as Assumed in Seismic Stress Analysis.Cause Not Stated + (06:26:15, 11 January 2025)
- 05000206/LER-1980-001, Forwards LER 80-001/01T-0 + (06:26:17, 11 January 2025)
- 05000206/LER-1979-024-03, /03L-0:on 791203,during Normal Operations,Mods Involving Instrumentation on Feedwater Flow Orifices & Steam Generator hi-lo Level Alarms Discovered Made W/O Approved Design Change.Caused by Failure to Follow Procedure + (06:26:20, 11 January 2025)
- 05000206/LER-1979-024, Forwards LER 79-024/03L-0 + (06:26:25, 11 January 2025)
- 05000206/LER-1980-002-01, /01T-0:on 800116,during Normal Operation,While Installing TMI Project Instrumentation,Auxiliary Relay Tripped & Shut East Feedwater Pump Discharge Valve, Resulting in Turbine Trip.Caused by Worker Bumping Relay + (06:26:29, 11 January 2025)
- 05000206/LER-1980-002, Forwards LER 80-002/01T-0 + (06:26:34, 11 January 2025)
- ML13330A839 + (06:26:36, 11 January 2025)
- 05000206/LER-1979-026-03, /03L-0:on 791226,during Test of Steam Driven Auxiliary Feedwater Pump,Pump Inboard Bearing Overheated & Failed.Caused by Lack of Lubrication.Review of Bearing Lubrication Sys Will Be Initiated + (06:26:39, 11 January 2025)
- 05000206/LER-1979-026, Forwards LER 79-026/03L-0 + (06:26:43, 11 January 2025)
- 05000206/LER-1979-025-03, /03L-0:on 791011,during Normal Operation,Loop C Variable Low Pressure Scram Setpoint Failed in Nonconservative Direction.Caused by Failure of Capacitor in Loop C T-ave R/I Converter.Capacitor Replaced + (06:26:48, 11 January 2025)
- 05000206/LER-1979-025, Forwards LER 79-025/03L-0 + (06:26:52, 11 January 2025)
- 05000206/LER-1979-017, Forwards Revised Chronology of Events for LER 79-017, Revision 1 Re Failure of 480-volt Bus 1.Change Basically Concerns Util Internal Communications + (06:26:56, 11 January 2025)
- 05000206/LER-1979-022-01, /01T-0:on 791130,supports on Component Cooling Water Sys Supply Header Found Missing.Supports Not Installed During Field Const.New Supports Installed 791202,conforming Piping Sys to Seismic Analysis Input Info + (06:27:05, 11 January 2025)
- ML13330A827 + (06:27:08, 11 January 2025)
- ML13330A825 + (06:27:10, 11 January 2025)
- ML13330A824 + (06:27:12, 11 January 2025)
- ML13330A823 + (06:27:14, 11 January 2025)
- 05000206/LER-1979-021-01, /01T-0:on 791114,while Making Routine Rounds, Operator Found 15 Volt Dc Power Supply on Y Subchannel of Load Sequencer Number 2 Had Tripped Off.Cause Unknown.Power Supply Reset & Sequencer Sucessfully Tested + (06:27:17, 11 January 2025)
- 05000206/LER-1979-021, Forwards LER 79-021/01T-0 + (06:27:20, 11 January 2025)
- 05000206/LER-1979-019-01, /01T-0:on 791116,during Field Verification/Insp, Three Supports Were Missing on Piping Used to Transfer Fuel to Diesel Generator.Supports Were Not Installed During Const.New Supports Installed on 791116 + (06:27:24, 11 January 2025)
- 05000206/LER-1979-019, Forwards LER 79-019/01T-0 + (06:27:28, 11 January 2025)
- 05000206/LER-1979-023-03, /03L-0:on 791010,during QA Audit,Variable Low Pressure Trip Setting on Pressure Channel Not Equal to Prescribed Computed Trip Value.Caused by Test Procedure Not Containing Acceptance Criteria.Procedure Revised + (06:27:36, 11 January 2025)
- 05000206/LER-1979-023, Forwards LER 79-023/03L-0 + (06:27:40, 11 January 2025)
- 05000206/LER-1979-020-01, /01T-0:on 791126,missing Valve Operator Support & Incorrectly Welded Valve Operator Support Discovered During Inspection.Caused by Poor Const.New Support Configuration Conforms Piping Sys to Seismic Input Info + (06:27:45, 11 January 2025)
- 05000206/LER-1979-020, Forwards LER 79-020/01T-0 + (06:27:50, 11 January 2025)
- ML13330A807 + (06:27:54, 11 January 2025)
- ML13330A806 + (06:27:56, 11 January 2025)
- 05000206/LER-1979-018-01, /01T-0:on 791109,support Discovered Missing on Liquid Radwaste Disposal Sys Piping Outside Containment. Caused by Failure to Install Support During Field Const. New Support Installed During 791110 Unrelated Outage + (06:28:00, 11 January 2025)