Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19320D488 + (08:02:54, 1 January 2025)
- ML19320D486 + (08:02:56, 1 January 2025)
- ML19320D485 + (08:02:59, 1 January 2025)
- ML19320D484 + (08:03:03, 1 January 2025)
- ML19320D483 + (08:03:05, 1 January 2025)
- ML19320D482 + (08:03:09, 1 January 2025)
- 05000313/LER-1980-020-03, /03L-0:on 800621,during Makeup Pump Test,Rod Index Limits Exceeded.Caused by Operator Inadvertently Opening Inlet to Standby Demineralizer.All Operators Reviewed Occurrence + (08:03:16, 1 January 2025)
- ML19320D480 + (08:03:17, 1 January 2025)
- ML19320D479 + (08:03:21, 1 January 2025)
- ML19320D477 + (08:03:22, 1 January 2025)
- 05000313/LER-1980-020, Forwards LER 80-020/03L-0 + (08:03:54, 1 January 2025)
- ML19320D474 + (08:04:02, 1 January 2025)
- ML19320D473 + (08:04:04, 1 January 2025)
- ML19320D472 + (08:04:06, 1 January 2025)
- ML19320D471 + (08:04:13, 1 January 2025)
- ML19320D468 + (08:05:20, 1 January 2025)
- ML19320D467 + (08:05:27, 1 January 2025)
- 05000366/LER-1980-093-03, /03L-0:on 800612,during Steady State Power, HNP-2-1050 Rounds Procedure Readings Showed Drywell Average Temp High.Caused by High Ambient Temp & Inadequate Cooling. Chilled Water Flow Increased + (08:05:44, 1 January 2025)
- ML19320D462 + (08:06:11, 1 January 2025)
- 05000366/LER-1980-093, Forwards LER 80-093/03L-0 + (08:06:40, 1 January 2025)
- ML19320D459 + (08:06:44, 1 January 2025)
- ML19320D458 + (08:06:46, 1 January 2025)
- ML19320D457 + (08:06:47, 1 January 2025)
- ML19320D456 + (08:07:24, 1 January 2025)
- ML19320D455 + (08:07:27, 1 January 2025)
- PM-80-709, Ro:On 800711,Unit 1 LPCI Inverter Tripped & Unit 2 4-kV Bus 2F Supply Breaker & HPCI Tripped.Supply Breaker Trip Caused by Jumper Missing from Neutral Leg.Motor Valve on HPCI Replaced Making It Operable.Events Submitted Per Ieb 80-17 + (08:07:29, 1 January 2025)
- ML19320D453 + (08:08:27, 1 January 2025)
- ML19320D452 + (08:08:30, 1 January 2025)
- ML19320D450 + (08:08:32, 1 January 2025)
- 05000306/LER-1980-017-03, /03L-0:on 800615,during Normal Operation,Found One Charging Pump Out of Svc.Charge Pump 23 Started & Shut Down.Caused by Air Leaks on Speed Control Unit Due to Broken Packing Ring.Packing Ring Replaced + (08:08:34, 1 January 2025)
- 05000306/LER-1980-017, Forwards LER 80-017/03L-0 + (08:08:38, 1 January 2025)
- 05000278/LER-1980-014-03, /03L-0:on 800608,while Performing ST 6.9,valve Mo 3-10-26B Failed to Close After Stroked Open.Caused by Mechanical Problem in Valve.Mo 3-10-26B to Be Disassembled & Repaired + (08:08:41, 1 January 2025)
- ML19320D445 + (08:08:46, 1 January 2025)
- ML19320D443 + (08:08:47, 1 January 2025)
- ML19320D442 + (08:08:48, 1 January 2025)
- ML19320D441 + (08:08:49, 1 January 2025)
- 05000321/LER-1980-076-01, /01T-0:on 800701,while Reactor Was at Hot Standby for Hpci/Reactor Core Isolation Cooling Testing,Site Notified by Ae That Listed RHR Supports Would Not Adequately Support All Design Based Loads + (08:08:52, 1 January 2025)
- 05000321/LER-1980-076, Forwards LER 80-076/01T-0 + (08:08:56, 1 January 2025)
- ML19320D437 + (08:09:03, 1 January 2025)
- ML19320D435 + (08:09:05, 1 January 2025)
- ML19320D434 + (08:09:06, 1 January 2025)
- ML19320D433 + (08:09:08, 1 January 2025)
- ML19320D432 + (08:09:11, 1 January 2025)
- ML19320D431 + (08:09:13, 1 January 2025)
- ML19320D430 + (08:09:16, 1 January 2025)
- ML19320D429 + (08:09:18, 1 January 2025)
- ML19320D428 + (08:09:20, 1 January 2025)
- ML19320D427 + (08:09:22, 1 January 2025)
- TXX-3162, Updates 800421 Deficiency Rept Re Discrepancies Involving Installation & Insp Requirements for Class 5 non-nuclear safety-related Piping Supports.Fsar Is Being Revised.Final Rept Will Be Forwarded by 800922 + (08:09:23, 1 January 2025)
- ML19320D425 + (08:09:29, 1 January 2025)
- ML19320D424 + (08:09:31, 1 January 2025)