- 05000301/LER-1989-003, :on 890712,tank B Level Channel 2LE-934 Began to Indicate Spuriously.Caused by Moisture Intrusion Between Halar Insulator & Sensing Rod.Level Detector Replaced & Channel Reestablished for Accumulator Tank B +
- 05000311/LER-1982-099, Forwards LER 82-099/03L-0.Detailed Event Analysis Encl +
- ML20085E505 +
- ML20100R429 +
- ML20244E153 +
- 05000301/LER-1989-003-01, :on 890712,level Channel 2LE-934 Declared Inoperable & Fill Operation Suspended When Channel Indicated Spuriously.Caused by Moisture Intrusion Between Halar Insulator & Sensing Rod.Detector Replaced +
- 05000293/LER-1992-016, :on 921213,automatic Scram Resulting from Load Rejection Occurred While at 48 Percent Reactor Power.Caused by 345 Kv Switchyard Flashovers Due to Salt Deposited During Severe Coastal Storm +
- 05000374/LER-1992-002-06, :on 920226,spurious Div 1 ECCS Initiation Signal Received When Freeze Seal Employed to Isolate Instrument Stop Valves Melted.Caused by Procedure Deficiency.Action Item Rept Issued +
- 05000311/LER-1982-099-03, /03L-0:on 820902,control Room Operator Received Indication of Low Svc Water Flow on Containment Fan Coil 23. Caused by Silt Buildup in Cooling Coils.Svc Water Flow Control Isolation Valve Cycled +
- 05000498/LER-1990-016, :on 900616,reactor Trip Initiated When 2 of 4 Coincidence Satisfied on Over Temp/Delta Temp.Caused by Less than Adequate Attention to Decreasing Margin to Over Temp/ Delta Temp Trip Setpoint.Procedures Revised +
- 05000416/LER-1990-017, :on 900916,reactor Scram Occurred Due to Loss of Balance of Plant Busses +
- 05000265/LER-1993-006-01, :on 930306,electromagnetic Relief Valve 2-203-3E Failed to Close During Routine Testing & Reactor Manually Scrammed.Caused by leak-off Line Sheared Off at 8-inch Discharge Header.Line Sent for Analysis +
- 05000281/LER-1993-006-03, :on 931115,Unit 2 Experienced Automatic Reactor Trip.Caused by Electrical Circuit Failure.Electrical Failure Traced to Defective Circuit Breaker & Replaced +
- 05000272/LER-1995-003-01, :on 950228,four Planned TS 3.0.3 Entries Occurred During Maintenance Analog Rod Position Indication Drift.Drift Caused by Mfg,Design,Const/Installation.Internal Adjustments to Rods Made +
- ML19114A253 +