- ENS 40469 +
- 05000247/LER-2001-001 +
- 05000272/LER-1981-038-03, /03L-0:on 810404,during Routine Testing,No Audible Fire Alarm Signals Were Generated.Caused by Out of Adjustment Limit Switch.Decoder & Limit Switch Readjusted, Cycled & Tested Satisfactorily +
- RC-11-0050, 2010 Annual Operating Report +
- ML19323G621 +
- ML20063G129 +
- ML20077Q127 +
- ML20137V536 +
- ML20138B635 +
- ML20135H305 +
- ML20198L304 +
- ML20207B087 +
- ML20206N226 +
- ML20203B081 +
- 05000301/LER-1982-005, Updated LER 82-005/01T-1:on 820727,discovered 2 of 3 Level Instruments on C Boric Acid Storage Tank Powered from Common Source.Cause Not Determined Due to Poor Early Maint of Documents.Wiring Corrected +
- ML20245F323 +
- 2CAN109504, Monthly Operating Rept for Sept 1995 for ANO Unit 2 +
- 05000338/LER-1989-005-01, :on 890225,unit Tripped from 76% Power When Initiating Signal for Reactor Trip Was Greater than Feedwater Flow Mismatch Coincident W/Low Steam Generator Level.Caused by Closure of Regulating Valve +
- 05000335/LER-1985-009-03, :on 851106,during Attempt to Lift Upper Guide Structure Out of Reactor vessel,1 of 3 Lift Bolts Failed. Caused by Insufficient Thread Engagement & Stripping.Reactor Vessel Maint Procedures Revised +
- 05000413/LER-1996-003-06, :on 960802,TS 3.0.3 Required Shutdown Initiated,Due to Ventilation Sys Motor Failures.Unit 2 Was Shutdown to MOD 5 Per Requirements of TS 3.0.3.Damaged Motors Were Replaced +
- 05000311/LER-1984-015, :on 840530,reactor Tripped from 10% Power During Shutdown.Caused by Conservative Setpoint Value & Excessively Large Reset Deadband of Intermediate Range High Flux Trip Bistables.Setpoint Reset +
- 05000498/LER-1995-001, :on 950124,experienced Reactor Trip Due to low- Low SG Level on 1C SG After Loss of MFW Pump 13.Caused by Failed Thrust Bearing Wear Probe Assembly.Thrust Bearing Wear Probe Assembly on MFW Pump 13 Replaced +
- 05000440/LER-1994-009, :on 940319,DG Returned to Rated Speed During Shutdown.Caused by Personnel Failure to Follow Procedures. Personnel Trained on DG Pneumatic Controls +
- 05000334/LER-1994-005-01, :on 940601,transformer Fault Initiated Voltage Disturbance on Electrical Grid Which Caused Relay Actuation Due to single-phase Insulating Bushing Failure.Completed Outage Repairs & Testing Activities +
- 05000301/LER-1982-005-01, /01T-0:on 820727,discovered Two of Three Level Instruments on Boric Acid Storage Tank C Powered from Common Source.Cause Unknown Due to Lack of Maint Documentation.Wiring Will Be Charged to Correct Problem +
- 05000277/LER-1990-025, :on 900913,high Pressure/Emergency Svc Water Ventilation Found Outside Design Basis Due to Deficient Design +
- 05000285/LER-1990-024, :on 901026,discovered Failure to Conduct Hourly Firewatch +
- 05000440/LER-1993-010, :on 930326,manual Reactor Scram Inserted Due to Rupture in 30 Inch Section of Underground SW Piping.Caused by Pipe Bending Due to Localized Loss of Soil Support. Failed Portion of SW Piping Being Repaired +
- 05000269/LER-1981-003, Forwards LER 81-003/03L-0.Detailed Event Analysis Encl +
- ML20035A751 +
- ML20035B167 +
- ML19329F815 +
- 05000272/LER-1981-038, Forwards LER 81-038/03L-0 +
- 05000397/LER-1994-006, :on 940330,discovered Broken HPCS-B1-DG 3 Battery Flag Terminal Weld.Caused by Poor Equipment Design. Damaged Battery Cell Replaced +
- 05000281/LER-2011-002, For Surry Power Station, Unit 2, Regarding Spurious Safety Injection Results in Exceeding Pressurizer Heatup Rate +
- 05000271/LER-2010-001, Regarding Automatic Reactor Trip Due to Switchyard Current Transformer Problem +
- B18813, November 2002 Monthly Operating Report for Millstone, Units 2 and 3 +
- B18799, October 2002 Monthly Operating Report for Millstone Units 2 & 3 +
- ML020320397 +
- ML20198R072 +
- 05000244/LER-1986-002, :on 860216,two Motor Operated Valves Required to Be Operable for Refueling Discovered Inoperable Due to 480-volt Bus 14 Outage.Caused by Lack of Tech Spec Clarity. Procedures Reviewed & Modified +