- ML20210F132 + (ML20210F132)
- 05000373/LER-1986-010-01, :on 860304,during Test LIS-PC-15,primary Containment Isolation Sys Groups II & IV Isolation Occurred. Caused When Jumper Became Grounded During Installation, Causing Fuse to Blow.Fuse Replaced + (ML20210F134)
- ML20210F138 + (ML20210F138)
- IR 05000344/1986047 + (ML20210F140)
- ML20210F142 + (ML20210F142)
- ML20210F143 + (ML20210F143)
- ML20210F148 + (ML20210F148)
- 05000373/LER-1986-009-02, :on 860225,during Reactor Protection Sys Bus B Transfer,Partial Group IV (ESF Actuation) Isolation Received W/Ventilation Fan Tripping.Caused by Alligator Clip Jumper Slippage Off Terminal Screw + (ML20210F150)
- ML20210F153 + (ML20210F153)
- ML20210F154 + (ML20210F154)
- ML20210F156 + (ML20210F156)
- TXX-6237, Forwards Revs to Comanche Peak Steam Electric Station Manuals + (ML20210F157)
- ML20210F158 + (ML20210F158)
- ML20210F167 + (ML20210F167)
- ML20210F172 + (ML20210F172)
- 05000373/LER-1986-007-03, :on 860226,discovered That Several Primary Containmet Isolation Valves Installed Using Wrong Gasket Matl,Invalidating Leak Rate Test Data.Caused by Inadequate Instructions.Adequate Instructions Provided + (ML20210F173)
- PY-CEI-NRR-0586, Forwards LERs 87-001-00 & 87-002-00 + (ML20210F176)
- ML20210F179 + (ML20210F179)
- ML20210F180 + (ML20210F180)
- ML20210F181 + (ML20210F181)
- ML20210F183 + (ML20210F183)
- ML20210F184 + (ML20210F184)
- ML20210F187 + (ML20210F187)
- ML20210F194 + (ML20210F194)
- ML20210F196 + (ML20210F196)
- 05000373/LER-1986-008-02, :on 860226,when Standby Liquid Control Sys Injection Test LOS-SC-R1 Commenced,Pressure Transient from Injection Line to Differential Pressure Indicator PDI-1B21-R005 Occurred.Caused by Air in Line + (ML20210F197)
- 05000263/LER-1987-002, :on 870108,trip of RHR Shutdown Cooling Supply High Pressure Interlock Occurred.Caused by Pressure Transient Which Tripped Interlock Pressure Switches.Return Lines & Shutdown Cooling Supply Flushed + (ML20210F198)
- ML20210F200 + (ML20210F200)
- ML20210F202 + (ML20210F202)
- ML20210F207 + (ML20210F207)
- ML20210F210 + (ML20210F210)
- ML20210F211 + (ML20210F211)
- 05000440/LER-1987-001, :on 870107,RWCU Containment Isolation Occurred Due to Indicated High Differential Flow.Caused by Flow Control Valve Problems.Engineering Design Change Implemented to Provide Mass & Temp Compensation for RWCU Instruments + (ML20210F213)
- ML20210F214 + (ML20210F214)
- ML20210F216 + (ML20210F216)
- ML20210F218 + (ML20210F218)
- ML20210F219 + (ML20210F219)
- 05000298/LER-1986-004, :on 860227,ESF,primary Containment Isolation Sys Group III Isolation Challenged During Cooldown.Caused by RWCU High Sys Flow of No More than 200%.RWCU Sys Lineup Reestablished & Sys Returned to Svc + (ML20210F221)
- ML20210F224 + (ML20210F224)
- ML20210F225 + (ML20210F225)
- ML20210F229 + (ML20210F229)
- ML20210F232 + (ML20210F232)
- ML20210F233 + (ML20210F233)
- ML20210F235 + (ML20210F235)
- ML20210F236 + (ML20210F236)
- ML20210F240 + (ML20210F240)
- ML20210F247 + (ML20210F247)
- ML20210F250 + (ML20210F250)
- ML20210F253 + (ML20210F253)
- ML20210F259 + (ML20210F259)
- ML20210F260 + (ML20210F260)