Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000395/LER-1985-009, :on 850325,external Consultant Identified Size Inadequacy of Containment Penetration Protection Devices for in-core Instrumentation Flux Mapping Space Heaters.Primary Protection Device Tagged Open Pending Mods + (ML20117C784)
- 3F0896-15, Discusses Violations Noted in NRC Insp Rept 50-302/96-03 Re Failure to Fulfill Escort Responsibilities + (ML20117C792)
- 05000250/LER-1985-010, :on 850330,subcooling Margin Monitors Considered Inoperable Per Tech Specs & Plant Shutdown.Caused by Failure of RCS Temp Elements to Meet Environ Acceptance Criteria.Elements Will Be Replaced + (ML20117C804)
- ML20117C805 + (ML20117C805)
- 05000327/LER-1985-014, :on 850404,during Calibr of Auxiliary Bldg Stack Radiation Monitor O-RM-90-101,inadvertent Auxiliary Bldg Isolation Occurred.Caused by Personnel error.SI-82 Revised to Ref 10 Time Delay for Channels + (ML20117C811)
- ML20117C820 + (ML20117C820)
- 05000244/LER-1985-005, :on 850405,leads of Resistance Temp Detector in Channel 4 Opened,Resulting in Reactor Trip Signal During Hot Shutdown.Only Actuation Was Automatic Opening of Reactor Trip Breakers.Caused by Personnel Error + (ML20117C825)
- ML20117C829 + (ML20117C829)
- 05000482/LER-1985-007, :on 850408,control Room Ventilation Isolation Signal Occurred During Surveillance Procedure in Mode 5. Caused by Personnel Error.Control Room HVAC Monitor Bypassed.Personnel Counseled + (ML20117C830)
- ML20117C833 + (ML20117C833)
- ML20117C843 + (ML20117C843)
- 05000482/LER-1985-008, :on 850409,ESF Actuation Signal Initiated While Resetting Flow on Containment Purge Gaseous Activity Monitor.Caused by Faulty Vacuum Transducer.Transducer Replaced + (ML20117C844)
- ML20117C846 + (ML20117C846)
- 05000321/LER-1985-019, :on 850403 & 05,reactor Water Cleanup (RWCU) Sys Pump Suction Primary Containment Valves 1G31-F001 & 1G31-F004 Isolated Three Times.Caused by High Ambient Temp in RWCU Pump Rooms 1A & 1B + (ML20117C853)
- 05000366/LER-1985-013-01, :on 850411,while in Refueling Mode,Full Reactor Scram Indicated.Investigation Determined That Full Reactor Protection Sys Logic Actuation Occurred.Caused by hi-hi Signal from Source Range Monitors + (ML20117C861)
- ML20117C868 + (ML20117C868)
- ML20117C884 + (ML20117C884)
- ML20117C889 + (ML20117C889)
- ML20117C931 + (ML20117C931)
- ML20117C935 + (ML20117C935)
- ML20117C942 + (ML20117C942)
- ML20117C946 + (ML20117C946)
- 05000362/LER-1984-044-01, :on 850320,determined That Instrument & Test Procedure S023-II-3.1 Did Not Require Testing of Control Element Assembly Calculator Penalty Factors as Required by Tech Specs.Procedure Revised + (ML20117C962)
- 05000305/LER-1985-010, :on 850405,reactor Trip Occurred Due to Steam Flow Greater than Feed Flow Signal Coincident W/Lo Steam Generator Level Signal.Caused by One Feed Flow & One Steam Low Transmitter Out of Calibr + (ML20117C969)
- 05000293/LER-1985-009, :on 850404,reactor Scrammed from 85% Power as Result of Turbine Trip on High Vibration Signal.Caused by Inadequate Lubrication of Turbine Vibration Detector.Lube Oil Orifice Cleaned & Detector Replaced + (ML20117C971)
- 05000259/LER-1985-012-01, :on 850408,discovered Standby Gas Treatment Sys Divisional Cables Routed Through Fire Stop/Pressure Seals Using Spare Cables Designated for nonsafety-related Use. Junction Box Also Determined Seismically Unqualified + (ML20117C977)
- 05000482/LER-1985-006, 00:on 850407,ESF Actuation Resulted Due to Inadvertent Actuation of Fuel Bldg Ventilation & Control Room Ventilation Isolation Signals.Caused by Personnel Error.Personnel Counseled + (ML20117C979)
- 05000370/LER-1985-007-01, :on 850327,overcurrent Relay Actuated on Spurious Condition Causing Loss of Power to Essential Switchgear 2ETA.Caused by Component Malfunction.Relay Replaced + (ML20117C998)
- 05000454/LER-1985-041, :on 850412,Train B Main Control Room Ventilation Sys Automatically Realigned to Makeup Mode. Caused by Personnel Error.Individual Counseled + (ML20117D000)
- 05000348/LER-1985-006-01, :on 850423,tube in Steam Generator 1c,plugged During Refueling Outage,Exceeded Pluggable Limit.Cause Not Stated.Results of Steam Generator Tube Inservice Insp Will Be Reported + (ML20117D002)
- ML20117D004 + (ML20117D004)
- ML20117D012 + (ML20117D012)
- ML20117D061 + (ML20117D061)
- ML20117D068 + (ML20117D068)
- ML20117D074 + (ML20117D074)
- ML20117D077 + (ML20117D077)
- ML20117D079 + (ML20117D079)
- ML20117D080 + (ML20117D080)
- ML20117D092 + (ML20117D092)
- ML20117D135 + (ML20117D135)
- ML20117D145 + (ML20117D145)
- ML20117D152 + (ML20117D152)
- ML20117D165 + (ML20117D165)
- ML20117D172 + (ML20117D172)
- ML20117D173 + (ML20117D173)
- 05000382/LER-1996-009-01, :on 960725,failure of Containment Vacuum Relief Valves CVR-402A & CVR-402B Occurred.Caused by Excessive Roughness in Valve Body Bore.Valves Replaced & Retested + (ML20117D184)
- ML20117D209 + (ML20117D209)
- ML20117D220 + (ML20117D220)
- ML20117D229 + (ML20117D229)
- ML20117D232 + (ML20117D232)
- ML20117D240 + (ML20117D240)