Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20097D317 + (ML20097D317)
- ML20097D322 + (ML20097D322)
- ML20097D326 + (ML20097D326)
- ML20097D327 + (ML20097D327)
- ML20097D328 + (ML20097D328)
- ML20097D332 + (ML20097D332)
- LIC-96-0013, Responds to NRC Re Violations Noted in Insp Rept 50-285/95-21 on 951105-1216 Corrective Actions:Barrel of Oil Removed from Area.Craft Personnel Briefed & Made Aware of Requirements of Standing Order SO-G-91 + (ML20097D333)
- ML20097D335 + (ML20097D335)
- 05000423/LER-1992-014-01, :on 920507,determined That Static Pressure Effect Not Accounted for in Setpoints of Veritrak Dp Transmitters.Caused by Incorrect Assumptions.Setpoints Methodology for Transmitters Will Be Reviewed + (ML20097D337)
- ML20097D341 + (ML20097D341)
- ML20097D342 + (ML20097D342)
- ML20097D347 + (ML20097D347)
- ML20097D353 + (ML20097D353)
- ML20097D355 + (ML20097D355)
- ML20097D357 + (ML20097D357)
- ML20097D359 + (ML20097D359)
- 05000282/LER-1996-002, :on 960109,inadvertent Opening of Supply Disconnect Switch to Safeguards Electrical Bus 15 Occurred. Caused by Personnel Error.Power Restored to Bus 15 + (ML20097D362)
- ML20097D363 + (ML20097D363)
- ML20097D364 + (ML20097D364)
- 3F0296-02, Informs NRC of Current & near-term Activities Further Enhancing Effectiveness of EOPs + (ML20097D369)
- ML20097D370 + (ML20097D370)
- ML20097D371 + (ML20097D371)
- ML20097D373 + (ML20097D373)
- ML20097D375 + (ML20097D375)
- Press Release-II-20-007, NRC Schedules Virtual Meeting to Discuss Performance of Honeywell Facility + (ML20097D378)
- 05000354/LER-1995-026, :on 951026,RMCS Found in locked-up Condition. Caused by Power Supply Problems to Display Memory Module Card File & Loose Clamp Screw.Power Supply to RMCS Dmm Replaced,Cards Cleaned & Connections Tightened + (ML20097D380)
- ML20097D382 + (ML20097D382)
- ML20097D385 + (ML20097D385)
- ML20097D388 + (ML20097D388)
- ML20097D390 + (ML20097D390)
- ML20097D392 + (ML20097D392)
- ML20097D393 + (ML20097D393)
- ML20097D394 + (ML20097D394)
- ML20097D395 + (ML20097D395)
- ML20097D396 + (ML20097D396)
- ML20097D397 + (ML20097D397)
- 05000269/LER-1995-007, :on 951106,LPIS Was Technically Inoperable Due to Deficient Design Change.Valves Modified to Prevent Key from Vibrating Out of Keyway + (ML20097D398)
- ML20097D402 + (ML20097D402)
- ML20097D404 + (ML20097D404)
- ML20097D406 + (ML20097D406)
- ML20097D408 + (ML20097D408)
- ML20097D411 + (ML20097D411)
- ML20097D412 + (ML20097D412)
- 05000282/LER-1996-001, :on 960106,MSSV Found Outside 1% Tolerance. Caused by Instrumentation Typically Used for Valve Testing Total Combined Inaccuracy of Slightly Less than +/- 1%. Valve Adjusted + (ML20097D414)
- ML20097D417 + (ML20097D417)
- ML20097D419 + (ML20097D419)
- ML20097D421 + (ML20097D421)
- ML20097D434 + (ML20097D434)
- RC-96-0030, Provides Notification of Listed Changes in Personnel for Plant + (ML20097D444)
- ML20097D446 + (ML20097D446)
- B15482, Application for Amend to License NPF-49,revising TS 4.0.5a, SRs for ISI & Testing Program & Bases Section 3/4.4.10, Structural Integrity, Consistent w/NUREG-1431 & NUREG-1482 + (ML20097D447)