- 05000397/LER-1984-008-01, Revised LER 84-008-01:on 840128,suppression Pool Level Indicator & Pool Level Fell Below Tech Spec Limits.Caused by Simultaneous Loss of Control Room Indication & Operation of Loop a of RHR Sys.Indication Reenergized + (ML20090G980)
- 05000368/LER-1980-088-03, Core Protection Calculator a & Control Element Assembly Calculator 1 Failed. Caused by Voltage Transient on 2Y11 & 2Y13.Sigma Indicator 2FI-8229-1 Replaced W/More Reliable Model + (ML20090G982)
- 05000397/LER-1984-027-01, Revised LER 84-027-01:on 840322,main Steam Relief Valve Solenoids Failed Due to Grounding in Solenoid Coils.Voltage Spike Suppression Diodes Installed Across Each Solenoid Circuit.Ge Conducting Review of Failures + (ML20090H001)
- ML20090H003 + (ML20090H003)
- 05000287/LER-1984-004-02, :on 840607,w/unit at 20% Power,Turbine Generator/Reactor Anticipatory Trip Occurred.Unit Stabilized at Hot Shutdown Conditions.Cause Unknown.Unit Restarted & Reached 100% Power on 840609 + (ML20090H008)
- ML20090H015 + (ML20090H015)
- ML20090H016 + (ML20090H016)
- ML20090H020 + (ML20090H020)
- 05000346/LER-1992-001, :on 920210,both Channels of Containment H Analyzer Inoperable & TS 3.0.3 Entered.Caused by Breaker Malfunction.H Analyzer AC Input Breaker Replaced & Labeling & Access Control to Circuitry Improved + (ML20090H026)
- ML20090H031 + (ML20090H031)
- 05000000/LER-1983-002-01, /01T-0:on 830405,spent Fuel Assembly X-13 Dropped Back Into Rack from Fully Lifted Position.Caused by Cable Stress Due to Limit Switch Failure.Insp for Cladding Damage Will Be Conducted + (ML20090H035)
- 05000255/LER-1984-007-01, :on 840622,work on Pressure Indicator Caused Number of Spurious Actuations of Low Temp Overpressure Protection Sys.Caused by Personnel Error.Proper Communication & Job Coordination Emphasized + (ML20090H049)
- ML20090H058 + (ML20090H058)
- ML20090H059 + (ML20090H059)
- 05000000/LER-1982-023-03, /03L-0:on 821121,containment Pressure Sensing Line Found Capped.Caused by Personnel Error.Units Will Be Labeled + (ML20090H065)
- 05000000/LER-1982-026-03, /03L-0:on 821115,turbine Driven Auxiliary Feedwater Pump 11 Failed to Deliver Full Flow of 200 Gpm to Steam Generators.Caused by Unscrewed Governor Valve.Valve Seat Reinstalled & Staked in Position + (ML20090H067)
- ML20090H068 + (ML20090H068)
- 05000000/LER-1983-001-01, /01T-0:on 830204,Exxon ECCS Analysis Error Discovered.Caused by Input Error Into Codes + (ML20090H070)
- ML20090H071 + (ML20090H071)
- 05000000/LER-1983-007-03, /03L-0:on 830330,steam Line Radiation Monitors Discovered Inoperable.Monitors Repaired & Surveillance Procedure Revised to Include Daily Check + (ML20090H073)
- ML20090H076 + (ML20090H076)
- 05000000/LER-1983-011-03, /03L-0:on 830510,diesel Generator D2 Tripped. Caused by Drift in Dryer Pressure Switch Model 1822.1. Switch Recalibr + (ML20090H077)
- ML20090H078 + (ML20090H078)
- 05000000/LER-1983-008-03, /03L-0:on 830410,right Hand Stop Valve Failed. Caused by Separation of Valve Disc from Clapper Arm Disc. Valve Repaired & Will Be Replaced at Next Refueling Outage. Left Hand Stop Valve Also Inspected + (ML20090H080)
- ML20090H086 + (ML20090H086)
- ML20090H090 + (ML20090H090)
- 05000445/LER-1992-004, :on 920206,discovered That 920130 Surveillance of Class 1E Battery Performed W/Battery in Equalize Rather than Float.Caused by Personnel Error.Personnel Involved Was Counseled.Battery Declared Operable + (ML20090H091)
- ML20090H092 + (ML20090H092)
- ML20090H093 + (ML20090H093)
- ML20090H097 + (ML20090H097)
- ML20090H100 + (ML20090H100)
- ML20090H107 + (ML20090H107)
- ML20090H109 + (ML20090H109)
- ML20090H116 + (ML20090H116)
- ML20090H117 + (ML20090H117)
- ML20090H132 + (ML20090H132)
- ML20090H139 + (ML20090H139)
- ML20090H141 + (ML20090H141)
- 05000397/LER-1984-068, :on 840628,control Room Emergency Filtration Unit Automatically Actuated Due to Spike on Corresponding Control Room Outside Air Radiation Monitor.Caused by RCIC Valve Closing During Testing.Alarm Reset + (ML20090H147)
- ML20090H150 + (ML20090H150)
- 05000315/LER-1984-008-01, :on 840617,reactor Trip & Safety Injection Occurred from Loss of Control Room Instrument Distribution Invertor Iv.Caused by Shorted C-2 Capacitor on Shorting Circuit Board.Design Change Installed + (ML20090H151)
- ML20090H152 + (ML20090H152)
- ML20090H153 + (ML20090H153)
- 05000254/LER-1992-004-03, :on 920207,Unit 1 Reactor Scram Occurred Due to Group I Isolation.Caused by Spurious Main Steam Line High Flow Trip Due to Unknown Cause.Applicable Instruments Calibr & Functionally Verified + (ML20090H155)
- ML20090H165 + (ML20090H165)
- ML20090H170 + (ML20090H170)
- TXX-4064, Final Deficiency Rept Re Premature Corrosion of Valves in Svc Water Sys.Initially Reported on 830919.Investigation Complete.Item Not Reportable Under 10CFR50.55(e) + (ML20090H174)
- ML20090H177 + (ML20090H177)
- ML20090H178 + (ML20090H178)