Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- NG-75-2001, AO 50-261/75-16:on 751028,svc Water Booster Pump B Failed to Start.Caused by Actuation of Pump Suction Pressure Switches Provided to Protect Pumps from Low Npsh.Containment Recirculation Fans Stopped to Prevent Overheating Motors + (ML20086F545)
- ML20086F546 + (ML20086F546)
- ML20086F549 + (ML20086F549)
- ML20086F550 + (ML20086F550)
- ML20086F551 + (ML20086F551)
- ML20086F553 + (ML20086F553)
- ML20086F554 + (ML20086F554)
- NG-75-1575, AO 50-261/75-15:on 750921,more than One Inoperable Rod Present W/Reactor at Power as Result of Rod Control Urgent Failure.Caused by Defective Fuse in Ac Power Supply to Rod Control Cabinet 1AC.Fuse Replaced + (ML20086F555)
- ELV-03238, Responds to NRC Re Violations Noted in Insp Repts 50-424/91-23 & 50-425/91-23.Corrective Actions:Events Will Be Classified Based on Highest Emergency Classification Which Are in Progress or Have Occurred + (ML20086F556)
- ML20086F561 + (ML20086F561)
- ML20086F562 + (ML20086F562)
- ML20086F568 + (ML20086F568)
- ML20086F572 + (ML20086F572)
- NG-75-1139, Summarizes Actions Taken Following AO 50-261/75-9 on 750501. Summaries of Repairs & Insps Performed During Forced Outage Given + (ML20086F574)
- ML20086F575 + (ML20086F575)
- ML20086F579 + (ML20086F579)
- NG-75-1158, AO 50-261/75-14:on 750715,valve V2-14B Steam Driven Auxiliary Feedwater Pump Discharge to Steam Generator B Failed to Open.Caused by Belleville Spring Being Filled W/Grease.Belleville Spring Packs & Shafts to Be Inspected + (ML20086F583)
- LIC-91-0277, Special Rept:On 911023,barrier Penetration 19-E-39,between Room 19 & Turbine Bldg,Breached to Support long-term Maint on Component Cooling Water Hxs.Compensatory Measures Implemented.Barriers Will Be Restored Prior to 920131 + (ML20086F591)
- ML20086F596 + (ML20086F596)
- RBG-36-035, Annual Environ Operating Rept for 900829-910828 + (ML20086F597)
- ML20086F600 + (ML20086F600)
- NG-75-1044, AO 50-261/75-12:on 750625,boric Acid Transfer Pump a Failed. Caused by Pump Shaft Being Broken at Keyway.Pump Rebuilt & Reinstalled.New Pump Model GVH-10K Will Be Installed Upon Receipt + (ML20086F603)
- ML20086F608 + (ML20086F608)
- ML20086F614 + (ML20086F614)
- ML20086F615 + (ML20086F615)
- NG-75-1212, Revised AO 50-261/75-11:on 750527,RCS Oxygen Concentration Found to Be 0.16 Ppm,Exceeding Limit.Caused by Inattention to Hydrogen Concentration & Dilution of RCS to Hot Shutdown Boron Concentration.Vol Control Tank Vented + (ML20086F616)
- ML20086F619 + (ML20086F619)
- ML20086F620 + (ML20086F620)
- ML20086F623 + (ML20086F623)
- ML20086F627 + (ML20086F627)
- ML20086F630 + (ML20086F630)
- 3F1191-12, Requests Temporary Waiver of Compliance from TS 3.0.4, Quadrant Power Tilt to Permit Unlimited Continued Plant Operation in Mode 1 W/Power Level Restricted to Less than 60% Rated Thermal Power,Per Generic Ltr 87-09 + (ML20086F631)
- ML20086F635 + (ML20086F635)
- NG-75-1089, Revised AO 50-261/75-8:on 750429,RHR Suction Valve RHR-862A Failed.Caused by Torque Switch on Motor Operator Being Out of Adjustment,Causing Valve to Be Wedged Onto Seat & Preventing Motor from Opening Valve + (ML20086F636)
- ML20086F641 + (ML20086F641)
- ML20086F644 + (ML20086F644)
- ML20086F647 + (ML20086F647)
- NG-75-1559, Forwards Responses to NRC Questions Re 750613 Rept on Wetted Insulation & Lagging Following Reactor Coolant Pump C Seal Failure.Summary of Piping & Insulation Insp to Be Performed During Next Refueling Outage Encl + (ML20086F652)
- ML20086F660 + (ML20086F660)
- ST-HL-AE-3928, Special Rept:On 911025,fuel Oil Leak Found at Injection Pump 9L of Standby Diesel Generator 21.Caused by Crack on Threaded Portion of Delivery Valve Holder.Holder Will Be Replaced W/New Cooper-Bessemer Holder by Next Outage + (ML20086F661)
- ML20086F664 + (ML20086F664)
- ML20086F667 + (ML20086F667)
- ML20086F674 + (ML20086F674)
- RBG-36010, Special Rept:On 911030,invalid Failure Occurred on Div III HPCS DG 1E22*EGS001 Due to Operator Error.Operations Personnel Shall Schedule Training to Ensure That Operations Personnel Understand Need for Proper Communications + (ML20086F680)
- ML20086F685 + (ML20086F685)
- ML20086F691 + (ML20086F691)
- ML20086F696 + (ML20086F696)
- ML20086F698 + (ML20086F698)
- ML20086F699 + (ML20086F699)
- ML20086F700 + (ML20086F700)
- ML20086F701 + (ML20086F701)