Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20086F409 + (ML20086F409)
- ML20086F412 + (ML20086F412)
- ML20086F414 + (ML20086F414)
- ML20086F415 + (ML20086F415)
- ML20086F418 + (ML20086F418)
- ML20086F422 + (ML20086F422)
- ML20086F423 + (ML20086F423)
- ML20086F426 + (ML20086F426)
- ML20086F433 + (ML20086F433)
- ML20086F445 + (ML20086F445)
- ML20086F459 + (ML20086F459)
- ML20086F470 + (ML20086F470)
- ML20086F471 + (ML20086F471)
- ML20086F473 + (ML20086F473)
- ML20086F479 + (ML20086F479)
- ML20086F482 + (ML20086F482)
- ML20086F487 + (ML20086F487)
- ML20086F489 + (ML20086F489)
- ML20086F492 + (ML20086F492)
- ML20086F493 + (ML20086F493)
- ML20086F497 + (ML20086F497)
- ML20086F500 + (ML20086F500)
- ML20086F502 + (ML20086F502)
- NG-75-2222, AO 50-261/75-20:on 751210,channel 950 of Containment Pressure Protection Found Inoperable.Caused by Open Output Fuse in Comparator PC-950.Fuse Replaced + (ML20086F509)
- NG-75-2210, AO 50-261/75-19:on 751208,boron Concentration Found Below Limits in Safety Injection Accumulator B.Cause Not Stated. Accumulator Partially Drained & Refilled from Refueling Water Storage Tank + (ML20086F510)
- ELV-03224, Responds to NRC Re Violations Noted in Insp Repts 50-424/91-26 & 50-425/91-26.Corrective Actions: Recommendations Incorporated Into Plant Procedures & Added Into Design Change Package + (ML20086F515)
- ML20086F516 + (ML20086F516)
- ML20086F521 + (ML20086F521)
- ML20086F522 + (ML20086F522)
- NG-75-2017, AO 50-261/75-18:on 751102,auxiliary Feedwater Pump a Failed to Start Following Safety Injection Signal.Caused by Tarnished Contacts.Contacts within Local/Remote Switch Cleaned.Further Investigation Underway + (ML20086F523)
- ML20086F529 + (ML20086F529)
- NRC-95-4489, Forwards W Rept WCAP-14383, W GOTHIC Code Description & Validation, (Nonproprietary) & W Rept WCAP-14382, W GOTHIC Code Description & Validation, (Proprietary).Proprietary W Rept WCAP-14382 Withheld.Also See 98093000240 + (ML20086F533)
- NG-75-2010, AO 50-261/75-17:on 751101,both Containment Personnel Air Lock Doors Opened Simultaneously W/Rcs Temp Above 200 F, Violating Tech Spec 3.6.1.a.Caused by Broken Rod,Bearing & Cam Follower on Outer Door Mechanism + (ML20086F534)
- ML20086F539 + (ML20086F539)
- ML20086F540 + (ML20086F540)
- ML20086F543 + (ML20086F543)
- 05000424/LER-1991-009-03, :on 911026,loss of Residual Heat Removal Pump Flow Occurred During Draindown of Reactor Cavity.Caused by False High RCS Level Indications.Procedures to Ensure Verification of Vent Paths revised.W/911122 1tr + (ML20086F544)
- NG-75-2001, AO 50-261/75-16:on 751028,svc Water Booster Pump B Failed to Start.Caused by Actuation of Pump Suction Pressure Switches Provided to Protect Pumps from Low Npsh.Containment Recirculation Fans Stopped to Prevent Overheating Motors + (ML20086F545)
- ML20086F546 + (ML20086F546)
- ML20086F549 + (ML20086F549)
- ML20086F550 + (ML20086F550)
- ML20086F551 + (ML20086F551)
- ML20086F553 + (ML20086F553)
- ML20086F554 + (ML20086F554)
- NG-75-1575, AO 50-261/75-15:on 750921,more than One Inoperable Rod Present W/Reactor at Power as Result of Rod Control Urgent Failure.Caused by Defective Fuse in Ac Power Supply to Rod Control Cabinet 1AC.Fuse Replaced + (ML20086F555)
- ELV-03238, Responds to NRC Re Violations Noted in Insp Repts 50-424/91-23 & 50-425/91-23.Corrective Actions:Events Will Be Classified Based on Highest Emergency Classification Which Are in Progress or Have Occurred + (ML20086F556)
- ML20086F561 + (ML20086F561)
- ML20086F562 + (ML20086F562)
- ML20086F568 + (ML20086F568)
- ML20086F572 + (ML20086F572)
- NG-75-1139, Summarizes Actions Taken Following AO 50-261/75-9 on 750501. Summaries of Repairs & Insps Performed During Forced Outage Given + (ML20086F574)