Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20086D892 + (ML20086D892)
- ML20086D895 + (ML20086D895)
- ML20086D897 + (ML20086D897)
- ML20086D899 + (ML20086D899)
- ML20086D903 + (ML20086D903)
- ML20086D905 + (ML20086D905)
- RC-95-0178, Comment on Proposed Review of NRC Insp Rept Content,Format & Style + (ML20086D906)
- ML20086D908 + (ML20086D908)
- ML20086D910 + (ML20086D910)
- 05000414/LER-1991-012-02, :on 911017,unexpected ESF Actuation Occurred, Resulting in Partial Actuation of ATWS Mitigation Sys & Actuation Circuit.Caused by Functional Design Deficiency in Circuit.Pump 2B Secured & Sys Realigned + (ML20086D912)
- ML20086D914 + (ML20086D914)
- ML20086D920 + (ML20086D920)
- ML20086D923 + (ML20086D923)
- ML20086D926 + (ML20086D926)
- ML20086D932 + (ML20086D932)
- ML20086D935 + (ML20086D935)
- U-602458, Responds to Ltr of 950503 Re Implementation of Access Authorization Program at Plant & Concludes That Concern Not Substantiated .Forwards Investigation Summary & Requests Witholding from Public Disclosure.W/O Encl + (ML20086D937)
- ML20086D939 + (ML20086D939)
- ML20086D940 + (ML20086D940)
- ML20086D945 + (ML20086D945)
- ML20086D946 + (ML20086D946)
- ML20086D950 + (ML20086D950)
- ML20086D953 + (ML20086D953)
- 0CAN119103, Submits Results of Review of Exams of Aerosol Cans of Fluorescent Magnetic Particle Prepared Bath,Per NRC Info Notice 91-031.Three Reactor Pressure Vessel Studs & Two Vessel Nuts Examined Using Cans from Recalled Batch + (ML20086D955)
- ML20086D958 + (ML20086D958)
- TXX-9135, Final Deficiency Rept CP-89-31 Re Tornado Dampers Unable to Travel to Full Open Position Due to Interference from thermolag-installed Adjacent Fire Dampers.Initially Reported on 891030.Condition Not Reportable for Unit 2 + (ML20086D959)
- 05000498/LER-1991-024, :on 911031,discovered That Updated Fsar,Chapter 15 Safety Analysis Did Not Consider Pressurizer Safety Relief Valve Loop Seal Delay Time.Caused by NSSS Vendor Error.Jco Issued on 911105 + (ML20086D961)
- ML20086D965 + (ML20086D965)
- ML20086D966 + (ML20086D966)
- ML20086D967 + (ML20086D967)
- ML20086D972 + (ML20086D972)
- ML20086D978 + (ML20086D978)
- ML20086D979 + (ML20086D979)
- ML20086D981 + (ML20086D981)
- ML20086D988 + (ML20086D988)
- ML20086D990 + (ML20086D990)
- ML20086D991 + (ML20086D991)
- ML20086D992 + (ML20086D992)
- ML20086D998 + (ML20086D998)
- ML20086D999 + (ML20086D999)
- ML20086E001 + (ML20086E001)
- 05000498/LER-1991-023, :on 911011,discovered Motor Lead Insulation Cracking on RHR Pumps in Trains a & C.Caused by Differences in Flexibility of Motor Lead Between Original Insulation & Insulation W/Raychem Sleeve.Cracks Repaired + (ML20086E003)
- ML20086E009 + (ML20086E009)
- PY-CEI-NRR-1416, Responds to Open/Unresolved Items Noted in Insp Rept 50-440/91-13 on 910819-30.Corrective Actions:Labeling Issue Will Be Resolved Via Rev to OAP-0507 & Design Change Will Be Pursued to Install Permanent Storage for Ladders + (ML20086E010)
- ML20086E015 + (ML20086E015)
- 05000328/LER-1995-004-02, :on 950525,observed That Containment Purge Air Inboard Isolation Valve May Not Have Sufficient Clearance for Actuator Proper Function During Loca.Caused by Personnel Error.Clearance Deficiency Corrected + (ML20086E016)
- ML20086E018 + (ML20086E018)
- ML20086E021 + (ML20086E021)
- 05000327/LER-1995-006, :on 950606,determined That Wga (Which Monitors Hydrogen Concentrations) Being Operated Incorrectly.Caused by Design Limitations.Alarm Logic Will Be Reconfigured to Ensure TS Compliance + (ML20086E028)
- 05000271/LER-1975-012, :on 750609,standby Liquid Control Pump B Delivered Flow Rate Above Tech Spec Max.Caused by Failure of Crosby Valve & Gage Relief Valve Model 1x2 to Seat Properly Due to Scored Surfaces.Valve Replaced + (ML20086E030)
- ML20086E032 + (ML20086E032)