- PLA-1968, Final Deficiency & Part 21 Repts Re Final Design of GE 7700 Series 250-volt Dc Control Ctrs.Plant Operating Procedures Revised to Include Methods of Clearing Obstructions as Provided by GE & Exam & Reforming of Draw Out Contacts + (ML20083F613)
- ML20083F617 + (ML20083F617)
- TXX-4089, Forwards Revised Pages from Chapter 17.1 of Fsar,Amend 44, Reflecting QA Program Decription Change.Rev Does Not Reduce Util Commitments Nor QA Program Effectiveness + (ML20083F618)
- ML20083F620 + (ML20083F620)
- ML20083F621 + (ML20083F621)
- 05000251/LER-1983-020-03, /03L-0:on 831123,during Return to Operation After Addition of full-flow Recirculation Piping,Reactor Taken Critical Before Piping Hydrotested at Pump Discharge Pressure.Caused by Previous Outmoded Hydrotest + (ML20083F623)
- ML20083F624 + (ML20083F624)
- ML20083F625 + (ML20083F625)
- 05000261/LER-1983-029-03, /03L-0:on 831122,w/unit Shut Down for Steam Generator Insp Outage,Level Transmitter LT-928 Found to Be Out of Calibr.Caused by Instrument Drift.Transmitter Recalibr + (ML20083F627)
- ML20083F628 + (ML20083F628)
- 05000416/LER-1983-130-03, Shutdown Cooling Sys Isolated Twice When Suction Valve Received Isolation Signals.First Isolation Caused by Personnel Error.Second Caused by Use of Alligator Clips + (ML20083F630)
- ML20083F637 + (ML20083F637)
- ML20083F640 + (ML20083F640)
- 05000333/LER-1983-059-04, /04T-0:on 831129,periphyton Exceeded 10 Times Control Sample for Co-60.Caused by Bioaccumulation Factor for Element.No Radiation Dose to Man Expected + (ML20083F642)
- 05000302/LER-1983-057-03, /03L-0:on 831122,during Emergency Feedwater Sys Operability Demonstration,Motor Actuator for Turbine Driven Emergency Feedwater Pump Steam Admission Valve ASV-5 Found Inoperable.Caused by Contact Failure + (ML20083F643)
- ML20083F645 + (ML20083F645)
- ML20083F646 + (ML20083F646)
- 05000334/LER-1983-036-03, /03L-0:on 831104,reactor Coolant Pump Thermal Barrier CCR Isolation Valves TV-CC-107A,B & C Not Stroked as Outlined in Inservice Insp Program.After 1980 Inservice Insp Rev,Valves Inadvertently Omitted + (ML20083F648)
- 05000366/LER-1983-138-03, /03L-0:on 831206,diesel Generator 2C(2R43-S001C) Could Not Be Shut Down W/Local or Control Room Stop Switch. Caused by Loose Governor Shutdown Solenoid Due to Engine Vibration.Solenoid Repositioned + (ML20083F650)
- ML20083F651 + (ML20083F651)
- ML20083F652 + (ML20083F652)
- 05000327/LER-1983-177-03, /03L-0:on 831122,diesel Generator 2A-A Declared Inoperable Due to Failure to Trip on Demand During Relay Testing.Cause of Failure of Differential Relay 87A Unknown. Relay Replaced + (ML20083F657)
- BSEP-83-3994, Nonroutine 30-day Radiological Environ Event Rept 2-SR-83-32 Re Gamma Analysis Results of Bottom Sediment sample.Co-60 Activity Increased by Factor of 10 Above MDA + (ML20083F658)
- 05000275/LER-1983-030-03, /03L-0:on 831116,discovered That Tech Spec Surveillance Requirement 4.3.3.3.1 for Channel Functional Test of Triaxial Time History Accelographs Not Performed. Caused by Personnel Error + (ML20083F660)
- ML20083F663 + (ML20083F663)
- GO2-83-108, Responds to NRC Re Violations Noted in IE Insp Rept 50-397/83-14.Corrective Actions:Sampling Plan Developed to Provide 95% Confidence Level That Less than 5% Defects Exist in Sample Lot + (ML20083F666)
- 05000325/LER-1983-054-03, /03L-0:on 831119,routine Surveillance Revealed That Div I Primary Containment Atmosphere Oxygen/Hydrogen Analyzer Not Showing Expected Decrease in Oxygen Concentration.Caused by Worn Seals + (ML20083F670)
- 05000289/LER-1983-044-01, /01T-1:on 831114,during Walkdown,Emergency Feedwater Automatic Initiation Redundant Circuits Discovered Routed in Same Cable Bundle.Caused by Failure to Include Circuits in Upgrade Design + (ML20083F671)
- ML20083F674 + (ML20083F674)
- 05000220/LER-1983-042-03, /03L-0:on 831122,fuel Zone Water Level Measuring Sys (Accurex) Taken Out of Svc to Modify Program to Improve Accuracy.Accurex Modified Per GE Recommendations & Returned to Svc in 1 H + (ML20083F679)
- ML20083F680 + (ML20083F680)
- 05000220/LER-1983-043-03, /03L-0:on 831128,fuel Zone Water Level Measuring Sys (Accurex) Found in Sys Idle Condition for Channel 11(A) at Time of Planned Surveillance Procedure N1-ISP-36- Icc.Cause Not Yet Known.Investigation Under Way + (ML20083F684)
- ST-HL-AE-1039, Final Deficiency Rept Re Tight Seal on Target Rock Pilot Actuated Solenoid Valves.Initially Reported on 831118.Valves May Be Replaced or Supplemented.Item Not Reportable Per 10CFR50.55(e) + (ML20083F685)
- 05000317/LER-1983-032-03, Containment Isolation Signal Logic Module B Would Not Actuate.Caused by Defective Electronic Logic Components.Module Replaced,Tested & Returned to Svc + (ML20083F688)
- 05000324/LER-1983-097-01, /01T-0:on 831212,during IE Bulletin 83-02 Testing, Crack Indications Identified in 19 of 131 Welds.Caused by Intergranular Stress Corrosion Cracking.Eight Welds Repaired.Remaining Indications Acceptable + (ML20083F691)
- ML20083F693 + (ML20083F693)
- ML20083F698 + (ML20083F698)
- 05000361/LER-1983-151-03, /03L-0:on 831114,w/unit in Mode 1,reactor Manually Tripped Due to Unexpected Pressurizer Pressure & Level Decrease.Caused by Operator Opening Emergency Boration Valve 2HV-9247.Training Program Revamped + (ML20083F699)
- ML20083F711 + (ML20083F711)
- ML20083F712 + (ML20083F712)
- ML20083F716 + (ML20083F716)
- IR 05000336/2020010 + (ML20083F717)
- ML20083F727 + (ML20083F727)
- ML20083F728 + (ML20083F728)
- ML20083F729 + (ML20083F729)
- 05000325/LER-1983-056-03, /03L-0:on 831127,control Board Position Indication Problems Identified in Control Rods 14-19,22-03 & 38-31. Caused by Defective Position Indication Probe Connectors or Reed Switches in Subj Rods + (ML20083F730)
- ML20083F735 + (ML20083F735)
- ML20083F738 + (ML20083F738)
- ML20083F739 + (ML20083F739)
- ML20083F742 + (ML20083F742)
- 05000338/LER-1983-086-03, /03L-0:on 831209,w/unit at 100% Power,Open Penetration Discovered in Fire Wall Between Motor Driven Auxiliary Feedwater Pump Room & Steam Driven Auxiliary Feedwater Pump Room.Wall Not Included in Test + (ML20083F745)