Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- AECM-83-0802, Forwards Description of Mod Required by License Condition 2.C(30) Re Remote Shutdown Panel,In Response to NRC FSAR Question 13.18(4).Full Compliance Will Be Met by Util by Installation of NRC Approved Design Mod Prior to Startup + (ML20083E978)
- ML20083E982 + (ML20083E982)
- PLA-1995, Ro:On 831121,determined That No Surveillances Were on Record for Ionization Smoke Detectors in Pgcc Modules in Fire Zones 0-24D & 0-27E.Work Authorization Issued to Test Detectors.Detectors Acceptable + (ML20083E983)
- ML20083E984 + (ML20083E984)
- ML20083E985 + (ML20083E985)
- RBG-16-496, Forwards Responses to 830523 & 0602 Requests for Addl Info Re Plant Personnel Training & Revised Sections of FSAR Chapter 13 + (ML20083E986)
- ML20083E989 + (ML20083E989)
- NRC-83-0065, Forwards Revised FSAR Page 14.2-34,correcting Abstract of RCS Hydrostatic Test S-03BB11 to Ref Applicable Code Requirements for Verification of Leaktightness.Correction Will Be Included in Rev 13 to Fsar,Expected Feb 1984 + (ML20083E990)
- 05000271/LER-1983-029-03, /03L-0:on 830630,quarterly Analysis of Stack Gas for Gross alpha,Sr-89 & Sr-90 Particulate Activity for Second Quarter 1983 Incomplete.Caused by Personnel Error. Required Analysis Completed + (ML20083E994)
- 05000317/LER-1982-002-03, Feeder Breaker 152-2101 Tripped Open,Causing Power Loss to 21 4-kV Bus.Caused by Failed Isolation Valve Applying False Hidden Trip Signal. Module Retrofitted w/MCT2 Optoisolator + (ML20083E998)
- ML20083F001 + (ML20083F001)
- ML20083F003 + (ML20083F003)
- AECM-83-0815, Documents Results of Bourns Potentiometer Retest,Per 831014 Commitment.Potentiometer Qualified to IEEE-323,1974 & IEEE-344,1975 + (ML20083F008)
- ML20083F010 + (ML20083F010)
- ML20083F013 + (ML20083F013)
- ML20083F018 + (ML20083F018)
- ML20083F020 + (ML20083F020)
- AECM-83-0811, Discusses Organization of Transamerica Delaval,Inc Diesel Engine Owners Group Detailed at 831221 Meeting in Atlanta, Ga.List of Attendees Encl.Requests Meeting During Wk of 840116 + (ML20083F023)
- ML20083F025 + (ML20083F025)
- ML20083F028 + (ML20083F028)
- ML20083F032 + (ML20083F032)
- GO2-83-115, Final Part 21 Rept on Condition 295 Re Standby Gas Treatment Unit Charcoal Filter Bed Leakage.Initially Reported on 831115.Gaps Between Frame & Perforated Plates Sealed W/Ge Sealant 727 + (ML20083F034)
- ML20083F035 + (ML20083F035)
- ML20083F036 + (ML20083F036)
- W3P83-4180, Submits Addl Info Re Emergency Feedwater (EFW) Control Sys, Per 831118 Request.Description of Contact States for Priority Close & Priority Open Actuation of EFW Control Valves Encl + (ML20083F039)
- LD-83-108, Forwards Responses to NRC Comments on Leak Before Break Evaluation of Main Loop Piping of C-E RCS, Per 831026 Meeting & 830614 Submittal.Max Seismic Moment Has No Impact on Loading of Axial Slot in Elbow + (ML20083F045)
- ML20083F050 + (ML20083F050)
- ML20083F054 + (ML20083F054)
- ML20083F059 + (ML20083F059)
- ML20083F061 + (ML20083F061)
- ML20083F063 + (ML20083F063)
- 05000220/LER-1983-040-03, /03L-0:on 831122,main Steam Radiation Monitor 122 Observed Gradually Degrading,Resulting in Low Readings. Caused by Loose Signal Cable Connector & Loss of Detector Sensitivity.Connector & Detector Replaced + (ML20083F075)
- 05000317/LER-1983-035-03, ESF Actuation Sys Channel Zg Steam Generator Level Found Tripped.Caused by Failure of Two Monsanto Mctz Optoisolators.All Optoisolators in Module Replaced W/Improved Design + (ML20083F078)
- ML20083F080 + (ML20083F080)
- 05000387/LER-1983-158-03, /03L-0:on 831115,wick for Control Structure Ventilation Sys Chlorine Detector a Discovered Not Dripping Electrolyte Solution.Caused by Clogged Wick.Wick & Orifice Cleaned + (ML20083F086)
- 05000289/LER-1983-045-03, /03L-0:on 831113,while Flowmeter FT-146 Out of Svc,Min Number of Channels Discovered Less than Required by Tech Spec 3.21-1.Caused by Misaligned Propeller Shaft & Slippage of Friction Wheel.Shaft Replaced + (ML20083F088)
- ML20083F090 + (ML20083F090)
- 05000219/LER-1983-019-03, /03L-0:on 831114,during Surveillance of Standby Gas Treatment Sys,Reactor Bldg Ventilation Valve V-28-22 Failed to Close on Isolation Initiation Signal.Caused by Piece of Piston Breaking Off.Piston Repaired + (ML20083F093)
- 05000387/LER-1983-152-01, /01T-0:on 831201,engineering Found Analyzed Drawdown Time of Secondary Containment to Be Longer than 60 FSAR Limit.Cause Unknown.Substantial Testing & Possible Mods Being Pursued + (ML20083F098)
- 05000220/LER-1983-044-01, /01T-0:on 831128,reactor Bldg Penetration Found Unsealed.Caused by Shrinking of Sealing Matl Forced Out of Penetration Due to Pressure Differential.Fire Watch Established.Penetration Resealed + (ML20083F104)
- 05000272/LER-1983-059-03, /03L-0:on 831128,air Lock Interior Door at Elevation 130 Ft Exhibited Leakage Rate Greater than Allowed by Tech Specs.Caused by Outer Seal of Interior Door Not Seated Properly in Groove.Personnel Retrained + (ML20083F105)
- ML20083F107 + (ML20083F107)
- ML20083F108 + (ML20083F108)
- ML20083F111 + (ML20083F111)
- ML20083F112 + (ML20083F112)
- ML20083F114 + (ML20083F114)
- ML20083F121 + (ML20083F121)
- ML20083F122 + (ML20083F122)
- ML20083F123 + (ML20083F123)
- ML20083F125 + (ML20083F125)
- 05000272/LER-1983-058-03, /03L-0:on 831118,air Lock Exterior Door Exhibited Leakage Rate Greater than Allowed by Tech Specs.Air Lock Declared Inoperable.Caused by Loose Door Latch Assembly.Door Latch Assembly Tightened + (ML20083F129)