- TXX-9122, Responds to NRC Re Violations Noted in Insp Rept 50-445/91-18 & 50-446/91-18 on 910422-29.Corrective Actions: Cognizant Depts Will Be Made Aware of Violation & Attention to Detail & Communication Will Be Emphasized + (ML20081G711)
- L-83-392, Responds to NRC Re Violations Noted in IE Insp Repts 50-250/83-14 & 50-251/83-14.Corrective Actions: Engineering Quality Instructions Will Be Clarified to Require That Seismic Loading of Cable Trays Be Considered + (ML20081G712)
- ML20081G729 + (ML20081G729)
- ML20081G732 + (ML20081G732)
- ML20081G738 + (ML20081G738)
- 05000362/LER-1983-073, /03L-0:on 830929,boronmeter 3AE0203 Rendered Inoperable When Manual Isolation Valves S31208MU084 & S31208MU091 Closed.Caused by Improper Sys Lineup.Corrective Actions Described in LER 83-073/03L-0 + (ML20081G741)
- ML20081G746 + (ML20081G746)
- ML20081G756 + (ML20081G756)
- ML20081G759 + (ML20081G759)
- RBG-16-218, Interim Deficiency Rept DR-121.Investigation Incomplete. Interim or Final Status Rept Expected by 831201 + (ML20081G767)
- 05000361/LER-1983-121-03, /03L-0:on 830927,calculations Indicated That DNBR Margin Not within Allowable Limits.Cause Unknown.Acceptable DNBR Margin Verified within 15 Minutes by Restoring Core Operating Limit Supervisory Sys + (ML20081G770)
- ML20081G777 + (ML20081G777)
- ML20081G784 + (ML20081G784)
- BSEP-83-3317, Responds to NRC Re Violations Noted in IE Insp Repts 50-324/83-30 & 50-325/83-30.Corrective Actions: Procedure Revised to Require Using Position Indications on Motor Control Ctr or Observation of Valve Stem Travel + (ML20081G791)
- ML20081G798 + (ML20081G798)
- ML20081G804 + (ML20081G804)
- ML20081G808 + (ML20081G808)
- 05000220/LER-1983-026-03, /03L-0:on 830909,inputs Indicated Excessive Drift Across Thermocouple B410.Cause Unknown.Poor Connection in Terminal Box Suspected.Corrective Action Will Be Determined During Next Cold Shutdown + (ML20081G812)
- 05000316/LER-1983-097-03, /03L-0:on 830925,west Essential Svc Water Supply Header Isolation Valve WMO-706 Removed from Svc to Repair Electrical Ground.Caused by Wire Pinched by Operator Access Cover.Wire Repaired + (ML20081G833)
- ML20081G834 + (ML20081G834)
- 05000315/LER-1983-102-01, /01T-0:on 831013,Part 21 Notification Received from Westinghouse Which Resulted in Possible Nonconservative Low Pressurizer Pressure ESF Actuation Setpoint.Setpoints Adjusted Prior to Entering Mode 4 + (ML20081G844)
- ML20081G860 + (ML20081G860)
- 05000333/LER-1983-038-03, /03L-0:on 830916,while Performing RHR Motor Operated Valve Operability Surveillance Test F-ST-2C,LPCI Valve 10MOV-25B Stopped in Middle of Open Stroke.Caused by Loosened Motor Pinion & Disloged Key + (ML20081G876)
- 05000250/LER-1983-016-03, /03L-0:on 831002,during Initiation of Cold Shutdown for Refueling,Letdown Isolation Valve CV-3-204 Failed to Close.Caused by Failed Solenoid Valve.Solenoid Valve Replaced + (ML20081G885)
- ML20081G890 + (ML20081G890)
- 05000327/LER-1983-122, Updated LER 83-122/03X-1:on 830927 & 28,diesel Generator 2A-A Declared Inoperable Due to Failure to Maintain Load of 4,400 Kw During Surveillance Testing.Caused by Faulty Exciter + (ML20081G897)
- 05000272/LER-1983-044-03, /03L-0:on 830926 & 1005,during Routine Surveillance,Containment Air Lock Failed to Meet Test Requirements.Caused by Improper Operation of Air Lock. Personnel Training Will Be Upgraded + (ML20081G898)
- ML20081G903 + (ML20081G903)
- ML20081G904 + (ML20081G904)
- ML20081G915 + (ML20081G915)
- 05000333/LER-1983-039-03, /03L-0:on 830920,main Steam Line Containment Low Pressure Switch Setpoint Found Less Conservative than Tech Spec Requirements.Caused by Instrument Drift.Setpoint Readjusted + (ML20081G916)
- ML20081G919 + (ML20081G919)
- ML20081G929 + (ML20081G929)
- ML20081G931 + (ML20081G931)
- ML20081G933 + (ML20081G933)
- NRC-95-0039, Submits Recent Changes to ERDS Data Point Library,Per NUREG-1394,rev 1 + (ML20081G942)
- 05000387/LER-1983-136-03, /03L-0:on 830918,24 & 27,reactor Bldg Zone I Ventilation Sys Tripped,Resulting in Differential Pressure of Less That Required 0.25-inches Vacuum.Caused by Actuated Differential Pressure Switch + (ML20081G945)
- ML20081G946 + (ML20081G946)
- 05000259/LER-1983-056-03, /03L-0:on 831003,radiochemical Lab Personnel Discovered Inlet Sample Hose CAM O-90-252 (Common) Disconnected.Caused by Personnel Moving Hose for Unknown Reasons.Sample Hose Reconnected + (ML20081G951)
- ML20081G955 + (ML20081G955)
- ML20081G956 + (ML20081G956)
- ML20081G958 + (ML20081G958)
- JPN-95-014, Responds to GL 94-02 Re thermal-hydraulic Instabilities in BWRs + (ML20081G959)
- ML20081G962 + (ML20081G962)
- ML20081G966 + (ML20081G966)
- ML20081G971 + (ML20081G971)
- ML20081G973 + (ML20081G973)
- ML20081G978 + (ML20081G978)
- ML20081G985 + (ML20081G985)
- ML20081G990 + (ML20081G990)
- 05000346/LER-1983-036, Revised LER 83-036/03X-1:on 830715 & 21,safety Features Actuation Sys Channel 4 Containment Radiation Monitor RE2007 Failed Low.Caused by Detector failure.RE2007 Replaced + (ML20081G991)