Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20081D810 + (ML20081D810)
- ML20081D812 + (ML20081D812)
- ML20081D827 + (ML20081D827)
- ML20081D836 + (ML20081D836)
- ML20081D848 + (ML20081D848)
- ML20081D849 + (ML20081D849)
- ML20081D851 + (ML20081D851)
- ML20081D856 + (ML20081D856)
- 1CAN039503, Monthly Operating Rept for Feb 1995 for Arkansas Nuclear One + (ML20081D860)
- ML20081D862 + (ML20081D862)
- ML20081D863 + (ML20081D863)
- ML20081D866 + (ML20081D866)
- ML20081D868 + (ML20081D868)
- 2CAN039501, Monthly Operating Rept for Feb 1995 for Arkansas Nuclear One + (ML20081D869)
- ML20081D876 + (ML20081D876)
- NRC-95-0028, Monthly Operating Rept for Feb 1995 for Fermi 2 + (ML20081D880)
- ML20081D889 + (ML20081D889)
- ML20081D891 + (ML20081D891)
- ML20081D899 + (ML20081D899)
- 05000334/LER-1983-023-03, /03L-0:on 830910,during Performance of Bvt 1.1-1.47.4 & 1.3-1.47.5 Discovered Valves & Flanges W/ Unacceptable Leakage.Caused by Inability to Hold Applied Pressure.Valves/Flanges Replaced + (ML20081D900)
- ML20081D901 + (ML20081D901)
- 05000389/LER-1983-063-03, /03L-0:on 830924,containment Gaseous Monitor Failed.Caused by Lightning Strike Scrambling Logic Circuits & Data Base.Logic Restored + (ML20081D902)
- HL-4807, Forwards Rev 1 to Ei Hatch Nuclear Plant Unit 2 COLR for Fuel Cycle 12 + (ML20081D907)
- ML20081D908 + (ML20081D908)
- ML20081D909 + (ML20081D909)
- ML20081D914 + (ML20081D914)
- ML20081D916 + (ML20081D916)
- ML20081D920 + (ML20081D920)
- 05000416/LER-1983-147-03, /03L-0:on 830919,determined Spare Parts,Purchased to Improper Quality Level Requirements,Installed in Chlorine Detection Sys.Engineering Design Group Included in Review Cycle for Procurement Documents + (ML20081D922)
- 05000338/LER-1983-065-03, /03L-0:on 830928,RCS Unidentified Leakage Exceeded 1 Gpm.Cause Not Stated.After Leakage Quantified & Verified Not to Be Pressure Boundary Leakage,Unidentified Leakage Decreased.Identified Leakage Increased + (ML20081D923)
- ML20081D924 + (ML20081D924)
- ML20081D931 + (ML20081D931)
- ML20081D934 + (ML20081D934)
- 05000280/LER-1983-044-03, /03L-0:on 830920,Periodic Test PT-39B-1 Revealed Snubber 1-SHP-HSS-1B Inoperable & 1-PT-39B-2 Revealed Snubbers 1-RC-HSS-146-147 Inoperable.Caused by Snubber Binding on Pipe & Empty Fluid Reservoir + (ML20081D940)
- BSEP-83-3519, RO 1-83-49:nongeometric Reflectors Discovered on Loop a & B Welds.Caused by Intergranular Stress Corrosion Cracking. Indications Will Be Repaired W/Weld Overlays + (ML20081D945)
- 05000281/LER-1983-038-03, /03L-0:on 830921,during RCS Integrity Test PT-11, Weld Leak Identified on Steam Generator a Channel Head Drain Piping at 2-RC-159.Cause Not Determined.Weld Completely Ground Out,Rewelded & Tested Satisfactorily + (ML20081D947)
- ML20081D949 + (ML20081D949)
- 05000338/LER-1983-062-03, /03L-0:on 830925,containment Sump Pump Discharge Isolation Valve TV-DA-100B Would Not Fully Close Either Automatically or Manually from Control Room.Caused by Mechanical Binding.Limit Switch Arm Realigned + (ML20081D952)
- NRC-83-0054, Forwards Revised Pages to Analysis of Main Steam Line Break W/Coincident Control Rod Withdrawal, Per 830202 Submittal Re SER Confirmatory Issues 13 & B.14 + (ML20081D958)
- ML20081D959 + (ML20081D959)
- 05000281/LER-1983-039-03, /03L-0:on 830926,w/unit at Hot Shutdown,Auxiliary Oil Pump for Charging Pump 2-CH-P-1A Observed Not Running. Cause Undetermined.Starting Coil Removed & Inspected.No Problems Found.Pump Performs as Designed + (ML20081D961)
- 05000366/LER-1983-103-03, /03L-0:on 830930,turbine Control Valve Fast Closure/Stop Valve Scram Bypass Alarm Would Not Clear, Indicating Scram Functions Still Bypassed W/Reactor at 30% Power.Caused by Broken Instrument Line + (ML20081D965)
- 05000321/LER-1995-002-01, :on 950216,trip of Reactor Protection Sys Power Supply Resulted in Actuations of Engineered Safety Features. Replaced Voltage Regulator & Wiring + (ML20081D970)
- 05000281/LER-1983-040-03, /03L-0:on 830921,w/unit in Hot Shutdown,Resistance of Motor for Auxiliary Feed Pump 2-FW-P-3A Discovered Degraded,Rendering Pump Inoperable.Caused by Rainwater Leaking Through Safeguards Bldg Roof Onto Motor + (ML20081D974)
- ST-HL-AE-5041, Forwards Supplemental Info for TS 3.8.2 Requiring Only One of Battery Chargers Associated W/Each Class 1E 125 Volt Dc Channel I & Channel IV to Be Operable + (ML20081D975)
- ML20081D981 + (ML20081D981)
- ML20081D982 + (ML20081D982)
- ML20081D987 + (ML20081D987)
- 05000325/LER-1983-043-03, /03L-0:on 831002,control Rod Drive Accumulator Low Pressure/High Water Level Alarm Annunciation Received for Control Rod 46-39.Accumulator Declared Inoperable + (ML20081D988)
- AECM-83-0659, Forwards Clarification to NRC Re Potential Effects of Containment Sprays on Equipment Survivability During Hydrogen Combustion.Effect Will Be Measured in 1/4- Scale Tests & Be Factored Into Survivability Analysis + (ML20081D990)
- ML20081D991 + (ML20081D991)