Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20079K731 + (ML20079K731)
- 05000416/LER-1982-157-03, /03L-0:on 821206,smoke Detectors in Control Room Zone 1-18 Alarmed & Would Not Reset.Caused by Welding Activities.No Smoke Found.Detector Cleaned + (ML20079K737)
- ML20079K749 + (ML20079K749)
- ML20079K750 + (ML20079K750)
- ML20079K767 + (ML20079K767)
- L-91-293, Forwards Rev 11 to Guard Training & Qualification Plan.Rev Withheld + (ML20079K775)
- ML20079K781 + (ML20079K781)
- 05000423/LER-1991-026-01, :on 910923,spurious High Radiation Control Bldg Isolation Signal Inadvertantly Actuated.Caused by Procedural non-compliance.Technicians Involved Counseled on Need to Ensure Good Communications + (ML20079K794)
- ML20079K806 + (ML20079K806)
- 05000289/LER-1991-003-02, :on 910927,turbine Control Valves Started Opening rapidly,once-through Steam Generator Pressure Began to Drop & Reactor Trip Occurred During Testing.Caused by Inadequate Procedure.Procedure Revised + (ML20079K807)
- ML20079K808 + (ML20079K808)
- 05000352/LER-1991-002-04, Has Been Withdrawn.Analysis Concluded That W/ Main Control Room HVAC Sys in Radiation Isolation Mode, Automatic Chlorine Isolation Not Required to Satisfy GDC 19 of 10CFR50,App a in Event of Chlorine Release + (ML20079K809)
- 05000334/LER-1991-027, :on 910926,insufficient Diesel Generator Fuel Oil Supply to Emergency Diesel Generators Noted.Caused by Inadequate Coordination Between Fuel Oil Supply Const & Licensing Process.Procedure Written + (ML20079K810)
- 05000482/LER-1991-018, :on 911002,containment Purge Isolation & Control Room Ventilation Isolation Signals Generated by Signals from Gaseous Channels of Radiation Monitors.Caused by High Gaseous Activity.Operators Counseled + (ML20079K814)
- ML20079K816 + (ML20079K816)
- ML20079K820 + (ML20079K820)
- SNRC-1001, Forwards Public Version of Revised Emergency Plan Implementing Procedures,Including Procedures EPIP 1-6 Re Evacuations,Epip 1-7 Re Personnel Accountability & EPIP 1-15 Re Security During Emergencies + (ML20079K827)
- ML20079K831 + (ML20079K831)
- ML20079K837 + (ML20079K837)
- ML20079K838 + (ML20079K838)
- ML20079K840 + (ML20079K840)
- ML20079K844 + (ML20079K844)
- ML20079K845 + (ML20079K845)
- 05000416/LER-1982-158, Forwards LER 82-158/99L-0 + (ML20079K847)
- 05000301/LER-1991-001-01, :on 910929,MSIVs Failed to Leave Fully Open Position During Attempt to Shut MSIVs from Control Room. Caused by Degradation of Valve Operators Due to Corrosion. Valve Operators Will Be Disassembled + (ML20079K848)
- 05000324/LER-1991-014-01, :on 910927,unplanned Reactor Protection Sys Actuation Occurred When Operators Realigned Scram Discharge Vol hi-hi Level Trip Bypass Switch.Caused by Failure to Follow Instructions.Operator Disciplined + (ML20079K853)
- ML20079K856 + (ML20079K856)
- ML20079K857 + (ML20079K857)
- ML20079K861 + (ML20079K861)
- ML20079K862 + (ML20079K862)
- 05000416/LER-1982-158-99, /99L-0:on 821130,safety-related Fire Barrier Removed During Maint Work on Control Room Floor.Caused by Need to Remedy Wiring Problem.Firewatch Established + (ML20079K868)
- BECO-91-147, Responds to Generic Ltr 91-06, Resolution of Generic Issue A-30, Adequacy of Safety-Related DC Power Supplies + (ML20079K874)
- ML20079K877 + (ML20079K877)
- 1CAN109110, Forwards Response to NRC 910730 Request for Addl Info on Confirmatory Analysis of Facility Boated Water Storage Tank. Revs 2 & 3 to Calculation 88-E-0034-14 Encl Also as Addl Supporting Info + (ML20079K882)
- ML20079K885 + (ML20079K885)
- ML20079K886 + (ML20079K886)
- BSEP-83-3336, Annual Rept of Changes,Tests & Experiments for 1982,per 10CFR50.59 + (ML20079K889)
- ML20079K890 + (ML20079K890)
- ML20079K891 + (ML20079K891)
- ML20079K901 + (ML20079K901)
- HL-1891, Special Rept 2-91-003:on 911003,during Performance of Battery Discharge Test,Two Emergency Lighting Units Failed to Illuminate for 8 H & Could Not Be Restored within 72 H. Lighting Units Repaired & Discharge Test Performed + (ML20079K902)
- ML20079K908 + (ML20079K908)
- 05000341/LER-1991-018, :on 911002,discovered Error in TS Amend 75, Resulting in Failure to Complete One of Two Weekly Channel Calibr Requirements for APRM Sys Channels.Caused by Use of Deficient Process.Calibr Performed + (ML20079K914)
- B10644, Interim Deficiency Rept SD-30 Re Cracks in Side Rail of Some Cable Tray Offset Reducers Due to Lack of Seam Welds in Const.Initially Reported on 821122.TJ Cope Co Contacted to Provide Recommendations for Corrective Actions + (ML20079K917)
- 05000416/LER-1982-155, Forwards LER 82-155/03L-0 + (ML20079K919)
- 05000416/LER-1982-155-03, /03L-0:on 821206,temporary Vent Exhaust Sys for Suppression Pool Area Found Operating & Discharging Into Air While Continuous Air Monitor Not Operating.Caused by Personnel Error.Personnel Reinstructed + (ML20079K930)
- ML20079K931 + (ML20079K931)
- 05000445/LER-1991-024, :on 911004,main Steam Safety Valves Had Lift Setpoints Less than Setpoint Tolerance Allowed by Ts.Caused by Inadequate Procedure.Setpoint Verification Procedure Revised + (ML20079K934)
- ML20079K937 + (ML20079K937)
- ML20079K939 + (ML20079K939)
- 05000445/LER-1991-023, :on 911003,reactor Tripped Due to Erratic Operation of Main Turbine Electrohydraulic Controller.On 910713,reactor Tripped Due to Seal Problem on Hydraulic Fluid Pumps.Design Mod Initiated + (ML20079K941)