Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000220/LER-1983-004-03, /03L-0:on 821130,shoreline Sediment Samples Yielded Concentration of Cs-137 in Excess of Tech Spec Requirements.Possibly Caused by Site Liquid Effluents. Addl Sampling Will Be Conducted + (ML20073A909)
- 05000244/LER-1983-010, Forwards LER 83-010/03L-0 + (ML20073A920)
- ML20073A935 + (ML20073A935)
- 05000244/LER-1983-010-03, /03L-0:on 830224,rod Position Indicator for Control Rod Bank SD Group 1 Position C09 Deviated from Control Bank SD by 12 Steps.Caused by Signal Error for Rod Position Indicator.Signal Adjusted to Correct Drift + (ML20073A954)
- ML20073A955 + (ML20073A955)
- ML20073A960 + (ML20073A960)
- ML20073A970 + (ML20073A970)
- 05000370/LER-1994-003-06, :on 940815,required Operability Surveillance of Ac Offsite Sources Not Performed During Inoperability of DG Room Sump Pump 2B2 Associated W/Dg 2B Due to Improper Work Practices.Required Surveillance Performed + (ML20073A977)
- 0CAN049111, 1990 Annual Financial Rept + (ML20073A980)
- ML20073A990 + (ML20073A990)
- ML20073A991 + (ML20073A991)
- 1CAN048301, Application for Tech Spec Change to License DPR-51,revising 830311 Submittal by Reformatting Acceptance Criteria Into Separate Section for Ease in Referencing & Clarifying Terminology + (ML20073A995)
- ML20073A999 + (ML20073A999)
- 05000445/LER-1991-011, :on 910322,oversight in Preparation of Temporary Mod Resulted in Failure to Meet Tech Spec Requirement.Caused by Personnel Error.Procedure Enhancement & Event Review Performed + (ML20073B001)
- ML20073B012 + (ML20073B012)
- ML20073B019 + (ML20073B019)
- ML20073B024 + (ML20073B024)
- ML20073B032 + (ML20073B032)
- ML20073B033 + (ML20073B033)
- ML20073B045 + (ML20073B045)
- ML20073B048 + (ML20073B048)
- ML20073B053 + (ML20073B053)
- ML20073B059 + (ML20073B059)
- ML20073B061 + (ML20073B061)
- NRC-91-0034, Detroit Edison 1990 Annual Rept + (ML20073B063)
- 05000445/LER-1991-009, :on 910321,automatic Isolation of Steam Generator Blowdown Occurred.Caused by Cognitive Personnel Error & Inadequate Procedural Guidance.Operations Shift Crew Counselled & Procedure Revised + (ML20073B065)
- ML20073B069 + (ML20073B069)
- 05000336/LER-1983-007-01, /01T-0:on 830318,nonconservative Safety Analysis Assumption Discovered in Steam Generator Tube Rupture Analysis.Caused by Failure of Analysis to Consider Impact of Automatic Valves.Analyses Will Be Docketed Shortly + (ML20073B075)
- LIC-91-0063, Comment Opposing Proposed Rule 10CFR50 Incorporating 1986- 1988 Addenda & 1989 Editions of ASME Boiler & Pressure Vessel Code,Section Iii,Div 1 & Section Xi,Div 1,by Ref Into 10CFR50.55a + (ML20073B076)
- ML20073B080 + (ML20073B080)
- ML20073B082 + (ML20073B082)
- ML20073B087 + (ML20073B087)
- ML20073B089 + (ML20073B089)
- ML20073B102 + (ML20073B102)
- ML20073B107 + (ML20073B107)
- ML20073B111 + (ML20073B111)
- ML20073B114 + (ML20073B114)
- PLA-3568, Comments Supporting Proposed Rule 10CFR50 Incorporating 1986 -1988 Addenda & 1989 Editions of ASME Boiler & Pressure Vessel Code,Section Iii,Div 1 & Section Xi,Div 1,by Ref Into 10CFR50.55a + (ML20073B115)
- ML20073B122 + (ML20073B122)
- ML20073B123 + (ML20073B123)
- ML20073B125 + (ML20073B125)
- ML20073B169 + (ML20073B169)
- ML20073B176 + (ML20073B176)
- U-602345, Monthly Operating Rept for Aug 1994 for Clinton Power Station + (ML20073B187)
- ML20073B194 + (ML20073B194)
- NLS9100241, Comment on NRC Proposed Amend to 10CFR50.55a Re Codes & Stds for Nuclear Power Plants.Suggests That Listed Comment Be Added to Proposed Rule to Clarify & Aid Licensees in Implementation of Rule + (ML20073B196)
- ML20073B202 + (ML20073B202)
- ML20073B207 + (ML20073B207)
- 05000443/LER-1994-011, :on 940621,contractor Mechanic Entered High Radiation Area W/O Possessing Alarming Dosimetry.Caused by Failure to Implement Self Checking.Radiation Worker Training Will Be Revised + (ML20073B219)
- RBG-40868, LAR 94-10 to License NPF-47,changing TS 3/4.2.2, APRM Setpoints in Order to Be Able to Operate Greater than 35% Rtp,Per Condition Identified During Review of GL 94-02 + (ML20073B227)
- ML20073B238 + (ML20073B238)