- ML20073A216 + (ML20073A216)
- 05000361/LER-1983-029, Forwards LER 83-029/03L-0 + (ML20073A219)
- ML20073A220 + (ML20073A220)
- ML20073A224 + (ML20073A224)
- ML20073A225 + (ML20073A225)
- 05000293/LER-1983-010, Forwards LER 83-010/03L-0 + (ML20073A226)
- ML20073A228 + (ML20073A228)
- ML20073A234 + (ML20073A234)
- SNRC-2181, Notifies of Equipment Changes to Shoreham Facility Which Have Occurred Subsequent to Rept on Phase I Final Survey Status,Provided in Util .Equipment Changes Described in Encl Table 1 + (ML20073A235)
- ML20073A240 + (ML20073A240)
- GO2-83-241, Responds to NRC Re Violations Noted in IE Insp Rept 50-397/83-03.Corrective Actions:Task Force Team Leaders Instructed to Review Letterbooks to Assure No Unanswered Quality Concerns Exist.Ir 3674 Addressed in Overall Review + (ML20073A244)
- JAFP-83-0210, Forwards 10CFR20.407 Rept,CY82 + (ML20073A249)
- ML20073A260 + (ML20073A260)
- ML20073A261 + (ML20073A261)
- 05000361/LER-1983-029-03, /03L-0:on 830304,RCS Water Balance Inventory Indicated 1.1 Gpm Unidentified Leakage.Caused by Excessive Plunger Packing Leakage at Chemical Vol & Control Charging Pump P-192 Discharge.Pump Repaired + (ML20073A263)
- 05000293/LER-1983-010-03, /03L-0:on 830222,two of Four Motor Operator Mounting Cap Screws Found Backed Out of Core Spray Valve MOV 1400-4A.Caused by Sys Vibration.Cap Screws Installed W/Thread Compound Applied.Redundant MOV 1400-4B Inspected + (ML20073A273)
- 05000316/LER-1983-028-03, /03L-0:on 830302,security Officer Found Carbon Dioxide Sys Isolated W/No Personnel Present in Cd Diesel Room.Cause Not Stated.Responsible Operators Reinstructed Re Proper Methods of Entering Protected Area + (ML20073A282)
- ML20073A292 + (ML20073A292)
- 05000336/LER-1983-005, Forwards LER 83-005/03L-0 + (ML20073A296)
- ML20073A301 + (ML20073A301)
- ML20073A324 + (ML20073A324)
- 05000316/LER-1983-029-03, /03L-0:on 830302,ESF Ventilation Sys Fan 2-HV-AES-2 Removed from Svc Due to Overheating Motor.Caused by Inboard Motor Bearing Failure.Motor Replaced + (ML20073A326)
- 05000336/LER-1983-005-03, /03L-0:on 830301,during Full Power,Rcs Unidentified Leak Rate Found in Excess of Tech Specs.Caused by Leaks in Valves 2-RC-405,2-SI-247 & Steam Generator Tube. Leaks Plugged + (ML20073A336)
- ML20073A344 + (ML20073A344)
- ML20073A349 + (ML20073A349)
- 05000316/LER-1983-030-03, /03L-0:on 830304,floor Penetration F-6922 Fire Barrier Seal Found Degraded.Caused by Misinterpretation of Procedure Wording,Allowing 1 H for Posting Fire Watch to Replace Temporary Seals.Responsible Individual Retrained + (ML20073A360)
- 05000373/LER-1991-003-05, :on 910319,lost Engineered Safety Feature Bus 143 During Surveillance.Caused by Deficient Procedure & Personnel Error.Training of Operational Analysis Dept Personnel Planned + (ML20073A361)
- ML20073A365 + (ML20073A365)
- ML20073A366 + (ML20073A366)
- 05000271/LER-1983-007, Forwards LER 83-007/03L-0 + (ML20073A373)
- AECM-83-0153, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/82-73.Corrective Actions:Specific Maint Work Order Written for Control Room Envelope Smoke Testing & Addl Training on Procedure 01-5-07-1 Initiated + (ML20073A379)
- ML20073A381 + (ML20073A381)
- 05000316/LER-1983-031-03, /03L-0:on 830225,reset Function for Proximity Switch on Stop Valve A,Train A,Failed to Reset Immediately. on 830304,proximity Switch Made Inoperable for Replacement. Cause Not Determined for Sluggish Reset Function + (ML20073A384)
- ML20073A388 + (ML20073A388)
- ML20073A396 + (ML20073A396)
- 05000271/LER-1983-007-03, /03L-0:on 830228,during Surveillance Testing, Reactor Bldg Vent Radiation Monitor 17-452A Actuated Above Tech Spec Limit.Caused by Setpoint Drift.Monitor Adjusted to Allowable Limit & Returned to Svc + (ML20073A408)
- ML20073A413 + (ML20073A413)
- 05000316/LER-1983-032-03, /03L-0:on 830304,outside Lower Containment Personnel Air Lock Door Found Open.Caused by Personnel Error.Tech Spec Requirements Discussed W/Involved Personnel + (ML20073A421)
- ML20073A424 + (ML20073A424)
- ML20073A425 + (ML20073A425)
- ML20073A426 + (ML20073A426)
- ML20073A440 + (ML20073A440)
- ML20073A448 + (ML20073A448)
- 05000316/LER-1983-033-03, /03L-0:on 830308,A Logic Test Position Tested Unsatisfactorily During Surveillance Test on Solid State Protection Sys Train B.Caused by Failure of Universal Card B-212.Logic Card Replaced + (ML20073A451)
- ML20073A459 + (ML20073A459)
- ML20073A463 + (ML20073A463)
- HL-4687, Monthly Operating Repts for Aug 1994 for Ehnp,Units 1 & 2.W/ + (ML20073A469)
- ML20073A471 + (ML20073A471)
- 05000339/LER-1991-001-03, :on 910318,surveillance Not Performed on PORV Control Circuitry.Caused by Incorrect Interpretation of TS & Administrative Error.Appropriate Procedure Will Be Revised Prior to Next Scheduled Surveillance + (ML20073A472)
- ML20073A473 + (ML20073A473)
- ML20073A481 + (ML20073A481)