Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000339/LER-1983-018-03, /03L-0:on 830227,w/unit in Mode 3 Following Reactor Trip,Source Range Detectors N-31 & N-32 Declared Inoperable After Receipt of Erroneous Readings.Caused by Energizing of Detectors on 830224.Detectors Replaced + (ML20072M883)
- ML20072M884 + (ML20072M884)
- ML20072M887 + (ML20072M887)
- 05000259/LER-1983-010, Forwards LER 83-010/03L-0 + (ML20072M894)
- 05000293/LER-1983-033-03, /03L-0:on 830601,governor for Diesel Generator B Failed to Properly Respond to Control Signals.Caused by Malfunctioning Mechanical Governor Supplied by Woodward Governor Co.Governor Replaced W/Spare + (ML20072M903)
- ML20072M904 + (ML20072M904)
- 05000339/LER-1983-022, Forwards LER 83-022/03L-0 + (ML20072M909)
- 05000259/LER-1983-010-03, /03L-0:on 830224,while Performing SI 4.7.B-3, Standby Gas Treatment Train B Declared Inoperable Due to Failure to Meet Flow Distribution Requirements.Caused by Debris in HEPA Filters.Filters Replaced + (ML20072M915)
- ML20072M917 + (ML20072M917)
- 05000416/LER-1982-156, Forwards Updated LER 82-156/03X-1 + (ML20072M920)
- ML20072M921 + (ML20072M921)
- 05000339/LER-1983-022-03, /03L-0:on 830304,w/unit in Mode 1,fire Door S54-7 Between Unit 1 Emergency Switchgear Room & Stairway to Control Room Declared Inoperable.Caused by Misadjustment of Reclosure Device & Door Latch.Device & Latch Readjusted + (ML20072M926)
- 05000416/LER-1982-156-03, While Performing Surveillance Test 06-OP-1P75-M-0002,Div II Diesel Failed to Start.Caused by Personnel Error.Fuel Leaks Due to Loose Bleed (Vent) Plugs.Plugs Tightened + (ML20072M932)
- ML20072M938 + (ML20072M938)
- ML20072M939 + (ML20072M939)
- ML20072M940 + (ML20072M940)
- ML20072M948 + (ML20072M948)
- B14943, Application for Amend to License NPF-49,revising Action Statement of LCO 3.7.5 of TS to Permit Facility to Remain in Modes 1,2,3 or 4 W/Average Water Temp of Ultimate Heat Sink Greater than 75 F for 24 H During Months of Aug & Sept 1994 + (ML20072M950)
- 05000328/LER-1983-030-03, /03L-0:on 830223,one Containment Sump Level Channel Declared Inoperable Due to Failure to Meet Channel Check Requirements.Caused by High Reading Due to Air Bubble in Oil Sense Line Ref Leg.Leg Refilled,Transmitter Recalibr + (ML20072M951)
- AECM-83-0379, Updated RO 83-023/1:on 830312,two Smoke Detectors in Standby Gas Treatment Filter Train Room (Zone 2-19) Covered While Conducting Welding Activities.Fire Watches Established. Detectors Should Be Operable by 830901 + (ML20072M955)
- ML20072M956 + (ML20072M956)
- 05000373/LER-1983-017, Forwards LER 83-017/03L-0 + (ML20072M968)
- 05000373/LER-1983-017-03, /03L-0:on 830222,lake Blowdown Flow Recorder Gave Incorrect Readings.Caused by Flow Instrument Probe Being Airbound Thus Preventing Transmittal of Correct Signal. Probe vented.LIS-WL-01 Performed Satisfactorily + (ML20072M980)
- ML20072M983 + (ML20072M983)
- ML20072M986 + (ML20072M986)
- 05000423/LER-1994-010-01, :on 940726,trains of Charging Declared Inoperable.Caused by Overly Restrictive Acceptance Criterion for Cooling Pump Bearing Oil Level.Cooling Pump Level Changed to Provide Appropriate Operability + (ML20072M991)
- ML20072M993 + (ML20072M993)
- 0CAN038325, Withdraws Request for Hearing Re Order Imposing Environ Qualification Requirements,Based on Listed Interpretations of Final Rule + (ML20072M994)
- ML20072N004 + (ML20072N004)
- PLA-1577, Ro:Recent Operations at Power Levels in Excess of Approx 65% Rated Power Accompanied by Indications of Nonmigrating Loose Part in or Near Reactor Vessel.Detectors Installed in Surrounding Area.Evaluation Continuing + (ML20072N005)
- RBG-40847, Forwards Fitness for Duty Performance Data for Period Jan- June 1994 + (ML20072N006)
- ML20072N012 + (ML20072N012)
- ML20072N019 + (ML20072N019)
- ML20072N023 + (ML20072N023)
- RBG-15-402, Interim Deficiency Rept DR-89 Re Potential Malfunction of Primary knife-type Disconnect Mfg by Rte Delta Corp & Used in Diesel Generators.Util Awaiting Addl Info from Ae.Next Rept Will Be Submitted by 830803 + (ML20072N024)
- 0CAN038318, Submits More Detailed Description of Chlorination Practices for Control of Future Infestations of Corbicula Species (Asiatic Clam),Per IE Bulletin 81-03,in Response to NRC 830121 Request.Chlorination Performed Biweekly + (ML20072N025)
- ML20072N027 + (ML20072N027)
- ML20072N028 + (ML20072N028)
- ML20072N031 + (ML20072N031)
- ML20072N033 + (ML20072N033)
- ML20072N038 + (ML20072N038)
- ML20072N040 + (ML20072N040)
- ML20072N043 + (ML20072N043)
- ML20072N045 + (ML20072N045)
- ML20072N046 + (ML20072N046)
- ML20072N048 + (ML20072N048)
- ML20072N054 + (ML20072N054)
- ML20072N059 + (ML20072N059)
- ML20072N063 + (ML20072N063)
- ML20072N065 + (ML20072N065)
- NRC-94-4276, Forwards Westinghouse Responses to NRC Requests for Addl Info on AP600,including Listing of NRC RAIs + (ML20072N066)