- ML20072J673 + (ML20072J673)
- 05000370/LER-1983-023-03, /03L-0:on 830524,upper Head Injection Surge Tank Low Pressure Alarm Received.Bulk Nitrogen Not Immediately Available & Pressure Fell Below Limit.Caused by Leakage of Gas Relief Valve on Nitrogen Accumulator + (ML20072J674)
- ML20072J675 + (ML20072J675)
- ML20072J679 + (ML20072J679)
- ML20072J680 + (ML20072J680)
- BSEP-83-1800, Ro:On 830502,gamma Analysis of Bottom Sediment Sample Detected Excessive Co-60 Activity.Sampling Frequency Increased from Semiannually to Monthly.Sample Represents Seventh Monthly Sample + (ML20072J682)
- ML20072J685 + (ML20072J685)
- 05000395/LER-1983-052-03, /03L-0:on 830528,main Control Board Indication for Steam Generator B Steam Pressure Failed High.Caused by Broken Wires on Transmitter PT-486 Strain Gage Assembly. Assembly replaced.PT-486 Calibr + (ML20072J686)
- ML20072J689 + (ML20072J689)
- 05000369/LER-1983-036-03, /03L-0:on 830524 & 26,listed Functional Test Procedures Failed to Satisfy Monthly Setpoint Requirements. Caused by Failure to Identify & Incorporate Changes Into Procedures.Setpoints Verified + (ML20072J693)
- ML20072J694 + (ML20072J694)
- 05000281/LER-1983-027-03, /03L-0:on 830523,PT-27C Revealed That Amp Reading for Heat Tracing Panel 8,circuit 22A Below Tech Spec Limit. Caused by Excessive Heat.Heat Tracing Replaced.Design Change initiated.W/830620 + (ML20072J698)
- ML20072J700 + (ML20072J700)
- ML20072J701 + (ML20072J701)
- ML20072J704 + (ML20072J704)
- 05000325/LER-1983-020-03, /03L-0:on 830524,intermediate Range Monitor a Indicated Instrument Upscale.Caused by Moisture Accumulation in Monitor Detector Cable Undervessel Connector.Connector Replaced + (ML20072J708)
- 05000259/LER-1983-026-03, /03L-0:on 830525,containment Atmosphere Dilution Tank B Level Transmitter LT-84-13A Indicated Above Tech Spec Limit.Caused by Transmitter Zero Drift.Transmitter Recalibr + (ML20072J723)
- ML20072J727 + (ML20072J727)
- ML20072J734 + (ML20072J734)
- ML20072J746 + (ML20072J746)
- ML20072J748 + (ML20072J748)
- ML20072J749 + (ML20072J749)
- ML20072J753 + (ML20072J753)
- ML20072J756 + (ML20072J756)
- 05000219/LER-1994-012, :on 940724,while Performing EMRV Pressure Sensor surveillance,as-found Trip Setpoints for High Pressure Relief Function on Two EMRVs Exceeded TS Limit Due to Instrument Drift.Pressure Switches Adjusted + (ML20072J760)
- 05000260/LER-1983-028-03, /03L-0:on 830526,during Normal Operation,Hpci Sys Declared Inoperable Due to Blown Inverter Fuse.Fuse Replaced.Hpci Turbine Control Valve Failed to Open Due to Misadjusted Rod.Rod Adjusted + (ML20072J761)
- ML20072J763 + (ML20072J763)
- ML20072J776 + (ML20072J776)
- 05000370/LER-1983-021-03, /03L-0:on 830521,while in Mode 2,control Room Steam Generator D Wide Range Level Recorder Indication Incorrect.Caused by Tube Fitting Leak on Level Transmitter high-pressure Sensor Line.Fitting Replaced + (ML20072J790)
- PY-CEI-NRR-0028, Addresses Commitment in Util Re Automatic Fire Detection Sys Recommended by 10CFR50,App R,Item Iii.F. Justification for Not Providing Automatic Detection in Areas Based on Low Potential for Uncontrolled Fire + (ML20072J799)
- ML20072J810 + (ML20072J810)
- ML20072J812 + (ML20072J812)
- ML20072J820 + (ML20072J820)
- BSEP-83-1979, Ro:On 830504,during Shutdown Operations,Limiting Conditions for Operations (LCO) Initiated for Inoperable Fire Door 203. Caused by Door Misalignment.Due to Job Planning considerations,7-day Time Frame of LCO Exceeded + (ML20072J823)
- ML20072J833 + (ML20072J833)
- ML20072J834 + (ML20072J834)
- ML20072J850 + (ML20072J850)
- ML20072J854 + (ML20072J854)
- ML20072J868 + (ML20072J868)
- ML20072J870 + (ML20072J870)
- ML20072J877 + (ML20072J877)
- ML20072J887 + (ML20072J887)
- ML20072J888 + (ML20072J888)
- ML20072J895 + (ML20072J895)
- 05000387/LER-1983-083-03, /03L-0:on 830520,during Review of Draft Procedures,Alarm Check Required by Tech Spec Not Included in Chemistry Surveillance Procedures.Change Made to Surveillance Procedures to Include Alarm Check + (ML20072J898)
- PLA-1701, Application to Amend License NPF-14,consisting of Proposed Amend 25 to Revise Physical Security Plan to Include Changes N,O & P & Changes a & B to Security Training & Qualification Plan.Change P Withheld (Ref 10CFR73.21) + (ML20072J900)
- ML20072J901 + (ML20072J901)
- ML20072J903 + (ML20072J903)
- ML20072J905 + (ML20072J905)
- RS-90-203, Circulating Water Sys Availability Analysis River Bend Nuclear Station + (ML20072J906)
- 05000387/LER-1983-075-01, /01P-0:on 830515,interactions of Chlorine Detector in Control Room Emergency Outside Air Supply Sys Noted Following Loss of Power.Procedure Changes Instituted to Provide Operators W/Appropriate Corrective Actions + (ML20072J909)