- 05000338/LER-1983-035-03, /03L-0:on 830528,following Rapid Rampdown from 100% to 0% power,I-131 Dose Equivalent Exceeded Tech Spec Limit.Level Returned to Limit within 12 H.Caused by Fuel Element Defect in Reactor Core + (ML20072J206)
- ML20072J208 + (ML20072J208)
- ML20072J214 + (ML20072J214)
- 05000389/LER-1983-016-03, /03L-0:on 830527,during Preoperational Testing,Two of Three Charging Pumps Inoperable for Approx 15 H.Caused by Sealwater Sys Gasket Leak & Charging Pump Relief Valve Failure.Pumps Repaired & Retested + (ML20072J217)
- BSEP-83-2048, Advises That LER 2-83-51 Re Inoperable CST Low Level Switch 2E41-LSL-N003 on 830524 Will Be Submitted by 830707 + (ML20072J232)
- ML20072J235 + (ML20072J235)
- ML20072J242 + (ML20072J242)
- ML20072J243 + (ML20072J243)
- ML20072J245 + (ML20072J245)
- ML20072J248 + (ML20072J248)
- 05000254/LER-1983-023-03, /03L-0:on 830522,electromatic Relief Valve Opened for No Obvious Reason at Aprrox 60 Psig.Caused by Electromatic Relief Pilot Valve Assembly Stuck in Open Position.Pilot Valve Replaced + (ML20072J257)
- ML20072J267 + (ML20072J267)
- 05000395/LER-1983-053-03, /03L-0:on 830528,reactor Vessel Upper Plenun Level Indicator ILI-1320 on Main Control Board Removed from Svc Due to High Reading.Caused by Instrument Drift.Programmable Function Generator Recalibr + (ML20072J274)
- ML20072J276 + (ML20072J276)
- ML20072J277 + (ML20072J277)
- TXX-3693, Final Deficiency Rept Re Adhesive Bond on Westinghouse Nlp (Loop Power Supply) Printed Circuit Cards.Initially Reported on 830601.Condition Not Reportable Under 10CFR50.55(e) + (ML20072J288)
- ML20072J292 + (ML20072J292)
- ML20072J294 + (ML20072J294)
- ML20072J297 + (ML20072J297)
- ML20072J308 + (ML20072J308)
- JAFP-94-0389, Responds to NRC Re Violations Noted in Insp Rept 50-333/94-13.Corrective Actions:Expectations on Responsibilities of Shift Supervisor,Assistant Shift Supervisor & STA Have Been Provided + (ML20072J315)
- ML20072J320 + (ML20072J320)
- 05000259/LER-1983-009-01, Design Review of Emergency Diesel Generator Engine Coolers Showed Coolers May Not Be Able to Maintain Cooling Water Below Hot Setpoint. Caused by Design Error.Setpoint Raised + (ML20072J322)
- ML20072J328 + (ML20072J328)
- ML20072J332 + (ML20072J332)
- ML20072J334 + (ML20072J334)
- ML20072J340 + (ML20072J340)
- ML20072J347 + (ML20072J347)
- ML20072J351 + (ML20072J351)
- TXX-3691, Final Deficiency Rept Re Class 1 Support Matl W/O Complete NDE Required for NF2500.Initially Reported on 830525.Item Not Reportable Under 10CFR50.55(e) + (ML20072J352)
- ML20072J361 + (ML20072J361)
- ML20072J364 + (ML20072J364)
- ML20072J366 + (ML20072J366)
- 0CAN058314, Responds to NRC Re Violations Noted in IE Insp Repts 50-313/83-02 & 50-368/83-02.Corrective Actions:Review of All Design Change Packages,Closed Out Since Administrative Procedures Revised,Expected by 830701 + (ML20072J367)
- ML20072J377 + (ML20072J377)
- ML20072J378 + (ML20072J378)