Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20071Q669 + (ML20071Q669)
- ML20071Q674 + (ML20071Q674)
- RBG-40781, Forwards Summary of Ref Leg Hardware Mod Completed on 940705,as Required by NRC Bulletin 93-003.Mod Added Continuous Backfill Sys for safety-related Reactor Pressure Vessel Instrument Ref Legs + (ML20071Q675)
- ML20071Q678 + (ML20071Q678)
- ML20071Q679 + (ML20071Q679)
- 05000458/LER-1994-019, :on 940624,SSW Pumps Automatically Started During Surveillance Testing of Div II Remote Shutdown Control Circuitry.Caused by Procedural Deficiency. Surveillance Tp STP-200-0602 Will Be Revised + (ML20071Q680)
- ML20071Q682 + (ML20071Q682)
- ML20071Q684 + (ML20071Q684)
- ML20071Q685 + (ML20071Q685)
- ML20071Q687 + (ML20071Q687)
- ML20071Q689 + (ML20071Q689)
- 05000334/LER-1982-012, Forwards Updated LER 82-012/01X-1 + (ML20071Q690)
- ML20071Q695 + (ML20071Q695)
- ML20071Q697 + (ML20071Q697)
- RBG-40785, Responds to Violation Noted in Insp Rept 50-458/94-13. Corrective Actions:Reactor Engineering Procedure REP-0029 Will Be Revised Prior to Refueling Outage 6 to Provide for Appropriate Confirmation of Fuel Movement Step Sequence + (ML20071Q698)
- ML20071Q699 + (ML20071Q699)
- ML20071Q702 + (ML20071Q702)
- ML20071Q704 + (ML20071Q704)
- ML20071Q709 + (ML20071Q709)
- ML20071Q712 + (ML20071Q712)
- ML20071Q716 + (ML20071Q716)
- ML20071Q717 + (ML20071Q717)
- ML20071Q719 + (ML20071Q719)
- ML20071Q720 + (ML20071Q720)
- ML20071Q722 + (ML20071Q722)
- 05000334/LER-1982-012-01, Total of Seven Overstressed Pipe Supports Found Upstream of Main Steam Line Containment Isolation Valves.Caused by Failure to Include Branch Line Loading in Calculations + (ML20071Q724)
- ML20071Q725 + (ML20071Q725)
- ML20071Q726 + (ML20071Q726)
- ML20071Q728 + (ML20071Q728)
- ML20071Q738 + (ML20071Q738)
- 05000220/LER-1982-015, Forwards LER 82-015/03L-0 + (ML20071Q742)
- ML20071Q743 + (ML20071Q743)
- ML20071Q749 + (ML20071Q749)
- ML20071Q751 + (ML20071Q751)
- NRC-94-4217, Forwards Proprietary Quick Look Data Rept for AP600 SPES-2 Test S01110,AP600 Program,July 1994. Rept Provides Info on AP600 Matrix Tests of Sufficient Depth to Enable Early Evaluation & Analysis of Test Results.Rept Withheld + (ML20071Q753)
- ML20071Q763 + (ML20071Q763)
- ML20071Q770 + (ML20071Q770)
- ML20071Q773 + (ML20071Q773)
- 0CAN058315, Provides Status of Transient Brochure Distribution Program. Purchase Order for Holders Issued & Delivery Expected by 830606 + (ML20071Q774)
- ML20071Q778 + (ML20071Q778)
- ML20071Q780 + (ML20071Q780)
- 05000267/LER-1982-045, Forwards LER 82-045/03L-0 + (ML20071Q781)
- 05000219/LER-1994-010, :on 940705,both Containment Spray & Emergency Service Water Systems Were Declared Inoperable.Caused by Biological Debris in Heat Exchangers.Cleaned,Inspected & Returned Heat Exchangers to Operability + (ML20071Q788)
- ML20071Q791 + (ML20071Q791)
- ML20071Q795 + (ML20071Q795)
- ML20071Q796 + (ML20071Q796)
- ML20071Q797 + (ML20071Q797)
- 05000220/LER-1982-015-03, /03L-0:on 821117 & 18,deluge Valves 101N & 101S, Protecting Reserve Power Transformer,Intentionally Made Inoperable to Replace Pressure Switches to Upgrade Fire Protection Sys.Deluge Sys Returned to Svc After Mod + (ML20071Q798)
- ML20071Q800 + (ML20071Q800)
- ML20071Q807 + (ML20071Q807)
- ML20071Q809 + (ML20071Q809)