Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20071L173 + (ML20071L173)
- ML20071L174 + (ML20071L174)
- ML20071L176 + (ML20071L176)
- ML20071L178 + (ML20071L178)
- ML20071L180 + (ML20071L180)
- 05000311/LER-1982-058-03, /03L-0:on 820702,svc Water Flow to Containment Fan Coil Unit 23 Less than Amount Required for Low Speed Operation.Caused by Oysters Plugging Valve.Oysters Removed. Development of Chlorination Program in Progress + (ML20071L182)
- ML20071L183 + (ML20071L183)
- ML20071L186 + (ML20071L186)
- ML20071L187 + (ML20071L187)
- ML20071L188 + (ML20071L188)
- ML20071L189 + (ML20071L189)
- ML20071L190 + (ML20071L190)
- 05000361/LER-1982-037-03, /03L-0:on 820518,remote Shutdown Monitoring Reactor Coolant Boron Concentration Instrument Declared Inoperable Following Receipt of Erratic Indications. Caused by Transmitter Module Including Extra Ground + (ML20071L194)
- ML20071L195 + (ML20071L195)
- ML20071L197 + (ML20071L197)
- ML20071L199 + (ML20071L199)
- ML20071L201 + (ML20071L201)
- ML20071L206 + (ML20071L206)
- 05000328/LER-1982-083, Forwards LER 82-083/03L-0 + (ML20071L221)
- ML20071L234 + (ML20071L234)
- ML20071L238 + (ML20071L238)
- 05000328/LER-1982-083-03, /03L-0:on 820624,during Mode 3 Operation, Containment Isolation Valve 2-FCV-43-61 Would Not Open. Caused by Condulet Cover Pinching Wire Which Resulted in Ground in Circuit.Damaged Wire Spliced & Tested + (ML20071L239)
- ML20071L240 + (ML20071L240)
- ML20071L242 + (ML20071L242)
- 05000286/LER-1982-004, Forwards LER 82-004/01T-0 + (ML20071L245)
- 05000325/LER-1982-068, Forwards LER 82-068/03L-0 + (ML20071L249)
- ML20071L251 + (ML20071L251)
- ML20071L256 + (ML20071L256)
- 05000286/LER-1982-004-01, /01T-0:on 820713,setpoints for Crosby Model Hb Pressurizer Safety Relief Valves PCV-466 & PCV-468 Discovered Below Tech Spec Limit During Cold Testing.Caused by Mechanical Valve Drift.Valves Reset + (ML20071L260)
- 05000325/LER-1982-068-03, /03L-0:on 820624,during Plant Operation, post-accident Drywell Particulate Radiation Detection Instrument 1-CAC-AQH-1262-1 Tripped & Would Not Restart. Caused by Power Supply Breaker Thermal Overload Trip + (ML20071L262)
- ML20071L266 + (ML20071L266)
- ML20071L268 + (ML20071L268)
- B14909, Application for Amend to License DPR-65,incorporating Change to TS 4.7.8.d,extending Surveillance Requirement Frequency for Snubber Functional Tests by AOT Extension to Extension to Current 18-month Surveillance + (ML20071L269)
- 05000317/LER-1982-022, Updated LER 82-022/01T-1:on 820503,total Type B & C Penetration Leakage Calculations Compared to Wrong Spec. Caused by Incorrectly Revised Local Leak Rate Surveillance Test Procedure.Procedure Revised + (ML20071L277)
- ML20071L279 + (ML20071L279)
- 05000361/LER-1982-065, Forwards LER 82-065/01T-0.Detailed Event Analysis Submitted + (ML20071L283)
- NRC-94-4211, Forwards Proprietary Preliminary Rept PXS-T2R-020,Rev 0, Quick Look Rept for SPES-2 Matrix Test S00401. Electronic Copy of Test Data in Rept Also Provided on Single 4mm Data Cartridge.Rept & Cartridge Withheld (Ref 10CFR2.790) + (ML20071L284)
- ML20071L287 + (ML20071L287)
- ML20071L288 + (ML20071L288)
- 05000361/LER-1982-065-01, /01T-0:on 820711,while Testing Control Room Emergency Air Cleanup Sys Chillers,Train B Chiller Tripped Immediately After Starting.Caused by Faulty Compressor Motor Bearing High Temp Alarm Module.Module Replaced + (ML20071L290)
- ML20071L293 + (ML20071L293)
- AECM-83-0196, Interim Deficiency Rept Re Defective Contact Button in Liberty Control Telephone Relays.Initially Reported on 830217.Investigation of Applicability to Unit 2 Underway. Deficiency Not Reportable for Unit 1.Final Rept by 830418 + (ML20071L297)
- ML20071L298 + (ML20071L298)
- AECM-82-329, Forwards Results of Comparisons Between Revised Independent Analysis & Mcdonald Engineering Rept Re HPCS Svc Water Pump Qualification.Based on Similar Results for Stresses on Pump Shaft,Issue as Identified in Suppl 2 to SER Resolved + (ML20071L300)
- 05000335/LER-1982-026, Forwards LER 82-026/03L-0 + (ML20071L303)
- 05000361/LER-1982-033, Forwards LER 82-033/03L-0.Detailed Event Analysis Submitted + (ML20071L308)
- 05000335/LER-1982-026-03, /03L-0:on 820622,one of Four Redundant 120-volt Ac Instrument Power Buses Was Lost When Output Breaker 1A Static Inverter Opened.Cause Unknown.Oscillator Circuit Board Replaced + (ML20071L312)
- L-83-222, Responds to Violations Noted in IE Insp Rept 50-389/83-13. Corrective Actions:Qc Inspector Given Verbal & Written Reprimand & Need for Strict Compliance Discussed at Weekly Electrical Inspectors Meeting + (ML20071L315)
- 05000361/LER-1982-033-03, /03L-0:on 820609,turbine Overspeed Protection Sys Rendered Inoperable.Caused by Need to Repair Oil Leaks on Unitized Actuator.Isolation Immediately Achieved Because MSIV Turbine Stop Valves Closed + (ML20071L316)
- ML20071L320 + (ML20071L320)
- ML20071L328 + (ML20071L328)