- ML20071K981 + (ML20071K981)
- 05000315/LER-1983-038-03, /03L-0:on 830421,during Normal Operation,Design Discrepancy in Wiring Discovered in Lower Containment Airborne Monitor Train A.Caused by Voltage Dips in Wiring. Wiring Corrected & Monitor Returned to Svc + (ML20071K995)
- ML20071L000 + (ML20071L000)
- ML20071L003 + (ML20071L003)
- ML20071L006 + (ML20071L006)
- ML20071L012 + (ML20071L012)
- ML20071L019 + (ML20071L019)
- 05000331/LER-1981-015, Updated LER 81-015/01T-1:on 810421,lower Crankshaft 14 Bearing Found Wiped on Journal Surface Similar to Problem Identified on Diesel 1G-31.Caused by High Temp.Bearing Replaced & Crankshaft Relapped + (ML20071L020)
- ML20071L022 + (ML20071L022)
- ST-HL-AE-4853, Forwards Objectives for Graded Emergency Response Exercise During Nov 1994 + (ML20071L023)
- 05000301/LER-1994-001, :on 940323,identified Potential FW Flow Measurement Inaccuracies Due to Degradation in Signals from Leading Edge Flow Meter Transducers.Permanent Changes Made to Reactor Engineering Procedures 1.4 & 6.2 + (ML20071L028)
- ML20071L029 + (ML20071L029)
- 05000336/LER-1983-016-03, /03L-0:on 830421,steam-driven Auxiliary Feedwater Pump Removed from Svc for Repacking.Caused by Natural End of Life Failure.Pump Repacked,Tested & Returned to Svc + (ML20071L031)
- 1CAN078205, Forwards Six Tech Spec Figure Change Requests for Approval. Changes Will Allow Extension of Cycle 5 from 435 Plus or Minus 10 Effective Full Power Days to 455 & Operation W/ Axial Power Shaping Rods Fully Inserted.W/O Encl + (ML20071L038)
- 05000244/LER-1982-015, Forwards LER 82-015/03L-0 + (ML20071L043)
- ML20071L047 + (ML20071L047)
- 05000361/LER-1982-052-03, /03L-0:on 820419,during Routine Shift Surveillance,Channel B Ammonia Analyzer of Toxic Gas Isolation Sys Was Declared Inoperable.Caused by Instrument Drift.Analyzer Repaired & Recalibr + (ML20071L049)
- 05000272/LER-1982-041, Forwards LER 82-041/03L-0.Detailed Event Analysis Encl + (ML20071L054)
- ML20071L059 + (ML20071L059)
- 05000331/LER-1981-016, Updated LER 81-016/01T-1:on 810421,lower Crankshaft Thrust Bearing 13 & Adjacent Bearing 12 Found Wiped on Journal Surface.Caused by High Temp.Crankshaft Thrust Bearings Replaced & Crankshaft Relapped + (ML20071L060)
- ML20071L062 + (ML20071L062)
- ML20071L063 + (ML20071L063)
- 05000259/LER-1982-005, Forwards Updated LER 82-005/03X-1 + (ML20071L066)
- ML20071L067 + (ML20071L067)
- NRC-94-4235, Forwards Ltr Rept NSD-TAP-3083, Suppl Documentation in Further Response to Request for Addl Info (TAC MB9116),Item 2A,in Support of Braidwood Unit 1 SG Tube Interim Plugging Criteria. Ltr Rept NSD-TAP-3083 Withheld,Per 10CFR2.790 + (ML20071L071)
- 05000244/LER-1982-015-03, /03L-0:on 820622,at steady-state 100% Operation, Periodic Test Identified Faulty Sealing of Containment Gas Radiation Monitor Return Line Check Valve.Caused by Dirt Deposits from Veins of Monitor Pump + (ML20071L072)
- 05000361/LER-1982-055-03, /03L-0:on 820228,channel B Ammonia Analyzer of Toxic Gas Isolation Sys Was Declared Inoperable.Caused by Instrument Drift.Analyzer Recalibr + (ML20071L074)
- ML20071L081 + (ML20071L081)
- ML20071L084 + (ML20071L084)
- 05000334/LER-1994-007-01, :on 940628,Reactor Plant River Water Pump WR-P-1B Automatically Started Due to Low River Water Header Pressure.Caused by Personnel Error.Walkdown Performed of Affected Piping + (ML20071L086)
- ML20071L087 + (ML20071L087)
- 05000272/LER-1982-041-03, /03L-0:on 820626,during Routine Insp,Water Discovered in Charging Pump 12 Gear Oil Reservoir.Caused by Leak Through Gear Oil Cooler.Cooler & Oil Replaced + (ML20071L090)
- NRC-94-4237, Forwards Responses to NRC RAIs on AP600 from Ltrs of 940428, 29,0502,05,16 & 26.Revs of Responses Previously Submitted Also Provided + (ML20071L098)
- B14803, Application for Amend to License NPF-49,proposing Changes to Ts,Addressing Shutdown Margins,Reactor Trip Sys & Heat Flux Hot Channel Factor + (ML20071L103)
- ML20071L106 + (ML20071L106)
- ML20071L107 + (ML20071L107)
- 05000361/LER-1982-054-03, /03L-0:on 820312,channel B Ammonia Analyzer of Toxic Gas Isolation Sys Was Declared Inoperable & Channel a Butane Analyzer Flamed Out.Caused by Instrument Drift & Flame Out.Analyzers Repaired & Recalibr + (ML20071L109)
- ML20071L111 + (ML20071L111)
- W3P82-2131, Forwards Amend 28 to Fsar,Consisting of Application to Amend Ol.Amend Provides Addl Info Addressing SER Issues Re Emergency Shutdown from Outside Control Room & TMI Action Items II.K.3.30 & II.B.2 + (ML20071L112)
- HL-4646, Provides Response to Questions Re Transmitter Replacements & Actions to Maintain High Degree of Confidence for Detecting Transmitter Failures Caused by Loss of fill-oil + (ML20071L116)
- AECM-83-0293, Ro:On 830418,smoke Detectors N604 A,B & C at Elevation 139 Ft in Auxiliary Bldg Covered to Prevent Continuous Alarm Condition from Welding Performed for Planned Maint Activity. Detectors Uncovered & Returned to Svc on 830509 + (ML20071L119)
- ML20071L120 + (ML20071L120)
- 05000361/LER-1982-058-03, /03L-0:on 820221,channel B Ammonia Analyzer in Toxic Gas Isolation Sys Was Declared Inoperable & Control Room Emergency Air Cleanup Sys Went Into Isolation Mode W/Channel a Out of Svc for Routine Maint.Analyzers Recalibr + (ML20071L124)
- ML20071L128 + (ML20071L128)
- ML20071L133 + (ML20071L133)
- HL-4650, Notifies of Completion of Actions Necessary to Meet GL 89-10 for Plant Hatch Units 1 & 2 + (ML20071L135)
- DCL-20-012, Response to NRC Request for Additional Information Regarding Diablo Canyon Power Plant, Units 1 and 2 - Post-Shutdown Decommissioning Activities Report + (ML20071L136)