Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20071H864 + (ML20071H864)
- 05000321/LER-1982-004-03, /03L-0:on 820202,during Refueling & While Performing HNP-1-3001,high Reactor Pressure Instrument Functional Test & calibr,1B21-N023C Found to Actuate at 1085 Psig.Caused by Setpoint Drift of Barksdale Model B2T + (ML20071H865)
- ML20071H867 + (ML20071H867)
- 05000324/LER-1982-017-03, /03L-0:on 820118,remote Shutdown Panel Suppression Chamber Water Temp Recorder 2-CAC-TR-778 Did Not Record Temps.Caused by Print Head Actuation Linkage Separating from Solenoid Due to Lack of Spring Tension + (ML20071H868)
- ML20071H869 + (ML20071H869)
- 05000296/LER-1983-025-03, /03L-0:on 830419,during Normal Operation,Drywell Temp Indicators IS-64-67,TI-64-52A & TM-64-52 Drifted Out of Tolerance & Beyond Tech Spec Limit.Instruments Recalibr & Functional Tested + (ML20071H870)
- 05000324/LER-1982-014, Forwards LER 82-014/03L-0 + (ML20071H874)
- ML20071H879 + (ML20071H879)
- ST-HL-AE-4842, Proposed Tech Specs Removing one-time Amends That Are No Longer Necessary + (ML20071H880)
- 05000325/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20071H882)
- ML20071H883 + (ML20071H883)
- 05000324/LER-1982-014-03, /03L-0:on 820117,primary Containment Atmospheric Oxygen analyzer,2-CAC-AT-1263-2,did Not Show Expected Trend in Drywell Concentration.Caused by Analyzer Components Heating Up Due to Stuck Thermostat Electrical Contacts + (ML20071H885)
- AECM-83-0282, RO 83-033/0:on 830411,fire-rated Penetrations Opened to Implement Design Change Packages.Hourly Fire Watches Established within 1 H & Will Be Maintained for Duration of Planned Maint Activities + (ML20071H886)
- ML20071H888 + (ML20071H888)
- ML20071H889 + (ML20071H889)
- ML20071H892 + (ML20071H892)
- ML20071H893 + (ML20071H893)
- BSEP-94-0262, Responds to NRC Re Violations Noted in Insp Repts 50-324/94-12 & 50-325/94-12.Corrective Actions:Restored Affected Equipment & Performed Audit of Canceled Clearances in 60 Days Day Holding File W/Boundary Extensions + (ML20071H895)
- ML20071H897 + (ML20071H897)
- ML20071H898 + (ML20071H898)
- 05000325/LER-1982-016-03, /03L-0:on 820123,containment Atmosphere Oxygen Monitor CAC-AT-1263-2 Would Not Calibr.Caused by burned-out Monitor Exciter Lamp.Lamp Replaced & Monitor Returned to Svc + (ML20071H899)
- ML20071H902 + (ML20071H902)
- 05000348/LER-1982-006-03, /03L-0:on 820128,during Realignment of Swing CCW Pump to a Train,Miscellaneous Header Misaligned cross-connecting Two CCW Loops.Caused by Failure to Perform FNP-2-SOP-23.0.Valves Properly Realigned + (ML20071H903)
- ML20071H904 + (ML20071H904)
- ML20071H906 + (ML20071H906)
- 05000366/LER-1982-007, Forwards LER 82-007/03L-0 + (ML20071H908)
- ML20071H910 + (ML20071H910)
- ML20071H911 + (ML20071H911)
- 05000327/LER-1983-058-03, /03L-0:on 830420,while in Mode 1,turbine Bldg Sump Radiation Monitor Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Debris from Sump Blocking Flow Switch.Flow Switch Cleaned + (ML20071H913)
- 05000324/LER-1982-022, Forwards LER 82-022/03L-0 + (ML20071H914)
- ML20071H917 + (ML20071H917)
- 05000366/LER-1982-007-03, /03L-0:on 820121,during 72% Steady Power,B Drywell Oxygen Concentration Indicator Swinging from 14% to 21%. Caused by Failure of B Sample Pump.Pump & Regulating Valve Repaired & Analyzer Recalibr + (ML20071H919)
- ML20071H920 + (ML20071H920)
- ML20071H924 + (ML20071H924)
- 05000366/LER-1982-009, Forwards LER 82-009/03L-0 + (ML20071H925)
- RBG-40727, Responds to NRC Re Violation Noted in Insp Rept 50-458/94-09.Corrective Action:Technicians Involved W/Event Were Counseled + (ML20071H926)
- ML20071H927 + (ML20071H927)
- ML20071H932 + (ML20071H932)
- ML20071H934 + (ML20071H934)
- ML20071H936 + (ML20071H936)
- ML20071H937 + (ML20071H937)
- 05000269/LER-1981-025, Forwards LER 81-025/03L-0.Detailed Event Analysis Encl + (ML20071H938)
- ST-HL-AE-4836, Responds to NRC Re Violation Noted in Insp Rept 50-499/94-16.Corrective Actions:Bolts on Fuel Injection Pump 2L Replaced & Properly Torqued & Hollow Studs Replaced W/New Solid Studs on Unit 2 Sdgs + (ML20071H944)
- ML20071H945 + (ML20071H945)
- 05000366/LER-1982-009-03, /03L-0:on 820123,at 61% steady-state Power,Narrow Range Torus Level Low Alarm Actuated at 145.7 Inches.Caused by Setpoint Drift.Transmitter,Recorder & Alarm Recalibr & Loop Returned to Svc + (ML20071H947)
- ML20071H949 + (ML20071H949)
- ML20071H952 + (ML20071H952)
- ML20071H953 + (ML20071H953)
- 05000269/LER-1981-025-03, /03L-0:on 811229 Discharge Valve 1LPSW-24 Could Not Be Reopened After Being Cycled & Shut to Stop Leakage, Rendering Reactor Bldg Cooling Unit C Inoperable.Caused by Operator Torque Limit Switches Vibrating Loose + (ML20071H954)
- ML20071H956 + (ML20071H956)
- ML20071H960 + (ML20071H960)