- ML20070U924 + (ML20070U924)
- ML20070U925 + (ML20070U925)
- 05000339/LER-1983-009, Forwards LER 83-009/03L-0 + (ML20070U926)
- 05000416/LER-1983-018, Forwards LER 83-018/99X-0 + (ML20070U929)
- ML20070U933 + (ML20070U933)
- 05000338/LER-1983-002, Forwards LER 83-002/03L-0 + (ML20070U937)
- 05000416/LER-1983-018-99, /99X-0:on 830105,diesel Generator 11 Unloaded & Secured Following Trip on High Bearing Temp & Indication of Increased Crankcase Pressure.Caused by Loose Sensor on Rear Main Bearing Allowing Air to Vent Off Pneumatic Logic Sy + (ML20070U940)
- ML20070U943 + (ML20070U943)
- 05000339/LER-1983-009-03, /03L-0:on 830112,train a Reactor Trip Breaker Bypassed for More than Allowed 2 H During Solid State Protection Sys Surveillance Testing.Cause Due to Necessity to Replace Damaged Universal Logic Card + (ML20070U944)
- 05000339/LER-1983-013-03, /03L-0:on 830113,during Mode 1,individual RPI for Rod P-06 in Control Bank a Deviated from Group Demand Position by Greater than 12 Steps W/No Rod Motion.Caused by Dirty Contacts on Signal Conditioning Module + (ML20070U946)
- 05000338/LER-1983-002-03, /03L-0:830104,meteorological Delta Temp Recorder Determined Out of Tolerance.Caused by Instrument Drift. Recorder Recalibr + (ML20070U951)
- 05000416/LER-1983-012, Forwards LER 83-012/03L-0 + (ML20070U953)
- 05000416/LER-1983-012-03, /03L-0:on 830106,fire Door OC505 in Control Bldg Blocked Open Due to Broken Hinge.Fire Watch Established & Hinge Repaired + (ML20070U960)
- 05000366/LER-1980-073, Forwards Updated LER 80-073/03X-1 + (ML20070U962)
- 05000335/LER-1982-071, Forwards LER 82-071/03L-0 + (ML20070U965)
- 2CAN049104, Advises That Util Intends to Utilize C-E Owners Group Low Temp Overpressure Protection Methodology in June 1991 Submittal of Tech Specs + (ML20070U966)
- 05000366/LER-1980-073-03, Hydrogen Combiner B Failed to Start During Test.Caused by Temp Controller Setpoint Too Close to Sys Trip Setpoint.Procedure Revised to Lower Controller Setpoint + (ML20070U976)
- 05000335/LER-1982-071-03, /03L-0:on 821230,turbine & Reactor Tripped, Resulting in DEQ I-131 Spike.Caused by Open Circuit in Reactor Protection Sys Trip Logic Due to 1A Inverter Frequency Oscillator Drift.Circuit Board Replaced + (ML20070U978)
- ML20070U982 + (ML20070U982)
- 05000335/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20070U987)
- ML20070U991 + (ML20070U991)
- ML20070U994 + (ML20070U994)
- ML20070U996 + (ML20070U996)
- ML20070V000 + (ML20070V000)
- 05000335/LER-1983-001-03, /03L-0:on 830104,channel Mc Containment Radiation Isolation Bistable Found to Trip at 10.117 R/H Vice 10 R/H Tech Spec Limit.Cause of Consolidated Control Model 6N88-1 Bistable Drift Undetermined.Setpoint Adjusted + (ML20070V003)
- 05000369/LER-1982-082, Forwards LER 82-082/03L-0 + (ML20070V006)
- 2CAN049101, Provides follow-up to 910403 & 04 Verbal Discussions Re Temporary Waiver of Compliance from Limiting Condition for Operation 3.0.4 for Containment Purge Isolation Valves Until Tech Specs Can Be Developed & Processed + (ML20070V010)
- 05000369/LER-1982-082-03, /03L-0:on 821231,while in Mode 5,three Instrument Loops Found Out of Tolerance.Caused by Differential Pressure Transmitter Drift.Transmitters Recalibr + (ML20070V011)
- SNRC-1805, Forwards 1991 Internal Cash Flow Projection for Facility,Per 10CFR140.21 + (ML20070V017)
- ML20070V018 + (ML20070V018)
- 05000325/LER-1983-004, Forwards LER 83-004/01T-0 + (ML20070V021)
- ML20070V025 + (ML20070V025)
- ML20070V027 + (ML20070V027)
- ML20070V030 + (ML20070V030)
- ML20070V035 + (ML20070V035)
- 05000333/LER-1991-002-01, :on 910304,opening Made in Wall to Install Telephone Cable Conduit Sleeve & Fire Watch Not Provided. Caused by Personnel Error & Deficient Procedures.Fire Watch Posted & Foreman Retrained + (ML20070V037)
- 05000260/LER-1982-035, Forwards Updated LER 82-035/03X-1 + (ML20070V038)
- ML20070V043 + (ML20070V043)
- 05000260/LER-1982-035-03, During Refueling Outage, While Performing Surveillance Insp 4.6.H-2,upper Mechanical Snubber on Main Steam Line D Found Inoperable.Snubber Replaced.Engineering Analysis Encl + (ML20070V046)
- 05000324/LER-1991-001-02, :on 910125,reactor Scram Occurred from 100% Power Due to Turbine Trip on High Reactor Water Level While Calibrating Feedwater Computer Point.Caused by Failure of Work Control Process.Calibrs Stopped + (ML20070V047)
- ML20070V050 + (ML20070V050)
- 05000366/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20070V055)
- ML20070V062 + (ML20070V062)
- 05000366/LER-1983-001-03, /03L-0:on 830107,while Performing ECCS Status Check Procedure,Drywell Hydrogen Oxygen Analyzer Discovered Inoperative.Caused by Moisture Accumulation in Regulator Sensing Line.Water Removed.Pump Diaphragms Replaced + (ML20070V063)
- ML20070V065 + (ML20070V065)
- 05000366/LER-1982-138, Forwards LER 82-138/03L-0 + (ML20070V066)
- 05000366/LER-1982-138-03, /03L-0:on 821229,while Performing RCIC Turbine Exhaust Diaphragm Pressure Instrument Ft&C Procedure,Rcic Trip & Throttle Valve Failed to Trip.Caused by Limit Switch Setpoint Drift.Limit Switch Adjusted Properly + (ML20070V075)
- ML20070V079 + (ML20070V079)
- 05000416/LER-1983-014, Forwards LER 83-014/03L-0 + (ML20070V082)
- 05000416/LER-1983-014-03, /03L-0:on 830107,during Cold Shutdown,Supervisory Sys Alarms for Several Fire Doors Found in Continuous Alarm & Would Not Reset.Caused by Problems W/Limit Switches, Latches & Magnets.Fire Watch Established.Doors Reworked + (ML20070V089)
- ML20070V101 + (ML20070V101)