Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20070U270 + (ML20070U270)
- ML20070U279 + (ML20070U279)
- ML20070U280 + (ML20070U280)
- ML20070U284 + (ML20070U284)
- 05000457/LER-1991-001-09, :on 910308,spurious Spiking Occurred from 2RE- AR012 Causing Containment Ventiliation Isolation Signal. Caused by Component Failure.Detector Replaced & Technical Staff Personnel Continues Radiation Monitoring + (ML20070U288)
- ML20070U293 + (ML20070U293)
- ML20070U296 + (ML20070U296)
- 05000219/LER-1991-001-01, :on 910301,deluge Sys Taken Out of Svc W/O Establishing Firewatch in Accordance W/Tech Specs.Caused by Personnel Error.Continuous Firewatch Assigned & Operations Mgt Reviewed Events + (ML20070U303)
- ML20070U328 + (ML20070U328)
- ML20070U332 + (ML20070U332)
- ML20070U362 + (ML20070U362)
- ML20070U370 + (ML20070U370)
- ML20070U372 + (ML20070U372)
- ML20070U378 + (ML20070U378)
- ML20070U399 + (ML20070U399)
- ML20070U418 + (ML20070U418)
- ML20070U420 + (ML20070U420)
- 05000456/LER-1991-003-04, :on 910312,sys Shifted to Emergency Mode of Operation Causing Momentary Loss of Voltage to Control Room Outside Intake Radiation Monitor.Caused by Momentary Fluctuation.Ventilation Sys Restored + (ML20070U442)
- ML20070U444 + (ML20070U444)
- ML20070U462 + (ML20070U462)
- ML20070U473 + (ML20070U473)
- ML20070U481 + (ML20070U481)
- ML20070U494 + (ML20070U494)
- ST-HL-AE-3734, Special Rept:On 910305,standby Diesel Generator Breaker Tripped.Caused by Failure of Voltage Regulator.Voltage Regulator Replaced & Post Maint Testing Completed.Plant Engineering Dept Will Review Failure Analysis + (ML20070U496)
- ML20070U504 + (ML20070U504)
- NRC-91-0042, Forwards Addl Info Re Associated Design Change.Recent Review of Second Refueling Outage Scope Determined That Implementation of New Controls Layout Should Be Deferred, Per + (ML20070U507)
- ML20070U508 + (ML20070U508)
- 05000293/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20070U510)
- ST-HL-AE-3701, Notifies of Revised Schedule for Implementation of Generic Ltr 89-13, Svc Water Sys Problems Affecting Safety-Related Equipment. Util Intends to Initiate Necessary Tests of Ccw/ Ecw HX During Fourth Refueling Outage + (ML20070U515)
- ML20070U524 + (ML20070U524)
- 05000293/LER-1983-001-03, /03L-0:on 830105,inboard Reactor Water Sample Isolation Valve AO-220-44 Did Not Close.Cause Will Be Investigated During Next Outage + (ML20070U529)
- ML20070U536 + (ML20070U536)
- PY-CEI-NRR-1342, Special Rept:On 910319,turbine Bldg/Heater Bay Vent Post Accident Radiation Monitor Declared Inoperable to Facilitate Performance of Calibr Procedure.Work Order Revised to Replace Failed Regulator + (ML20070U542)
- ML20070U575 + (ML20070U575)
- ML20070U580 + (ML20070U580)
- ML20070U586 + (ML20070U586)
- 05000387/LER-1983-003, Forwards LER 83-003/03L-0 + (ML20070U588)
- ML20070U589 + (ML20070U589)
- 05000387/LER-1983-003-03, /03L-0:on 830101,required Vacuum of HVAC Zone III Not Maintained.Caused by Pressure Fluctuations at Exterior Delta Pressure Sensor Due to Excessive High Winds.Vacuum Setpoint Raised to Decrease Sensitivity + (ML20070U599)
- ML20070U606 + (ML20070U606)
- ML20070U610 + (ML20070U610)
- ML20070U618 + (ML20070U618)
- JSP-239-91, Responds to Generic Ltr 89-10, Safety-Related Motor Operated Valve Testing & Surveillance. Informing That Program to Address Generic Ltr Requirements in Place & Necessary to Change Design Basis Review + (ML20070U619)
- ML20070U627 + (ML20070U627)
- ML20070U634 + (ML20070U634)
- ML20070U642 + (ML20070U642)
- ML20070U647 + (ML20070U647)
- ML20070U649 + (ML20070U649)
- ML20070U653 + (ML20070U653)
- ML20070U656 + (ML20070U656)
- ML20070U659 + (ML20070U659)