- ML20070P707 + (ML20070P707)
- 05000317/LER-1982-081, Forwards LER 82-081/03L-0 + (ML20070P730)
- 05000317/LER-1982-081-03, /03L-0:on 821227,snubber 1-83-53 Found Inoperable. Caused by Low Oil Reservoir Due to Leakage at rod-end Cylinder Seal.Snubber Replaced + (ML20070P737)
- ML20070P738 + (ML20070P738)
- ML20070P746 + (ML20070P746)
- ML20070P750 + (ML20070P750)
- 05000278/LER-1982-025-03, /03L-0:on 821214 & 18,torus Normal Range Level Recorder Not Responding to Changes in Level.Caused by off-centered Displacer to Force Arm Connection in Level Transmitter.Arm Centered + (ML20070P752)
- 05000387/LER-1982-076, Forwards LER 82-076/03L-0 + (ML20070P753)
- ML20070P756 + (ML20070P756)
- ML20070P765 + (ML20070P765)
- 05000387/LER-1982-076-03, /03L-0:on 821217,recirculation Pump B Tripped During Startup Test.Caused by Technician Placing Instrument Leads on Wrong Terminals While Attempting to Obtain Test Data.Procedure to Obtain Test Data Revised + (ML20070P767)
- LIC-94-0085, Responds to NRC Re Violation Noted in Insp Rept 50-285/94-03 on 940102-0212.Corrective Actions:Supervisor - Sys Engineering Issued Memo to Sys Engineering Personnel Outlining Requirements for Reporting Equipment Problems + (ML20070P769)
- ML20070P772 + (ML20070P772)
- ML20070P776 + (ML20070P776)
- ML20070P780 + (ML20070P780)
- ML20070P795 + (ML20070P795)
- ML20070P801 + (ML20070P801)
- ML20070P814 + (ML20070P814)
- ML20070P816 + (ML20070P816)
- 05000281/LER-1982-076, Forwards LER 82-076/03L-0 + (ML20070P826)
- ML20070P828 + (ML20070P828)
- ML20070P836 + (ML20070P836)
- ML20070P860 + (ML20070P860)
- ML20070P862 + (ML20070P862)
- ML20070P870 + (ML20070P870)
- 05000281/LER-1982-076-03, /03L-0:on 821217,discovered B Train of Auxiliary Feedwater Motor Operated Valves Not Opening on Steam Generator low-low Level.Caused by Incomplete Wiring for Design Change 76-69 + (ML20070P875)
- ML20070P884 + (ML20070P884)
- ML20070P887 + (ML20070P887)
- ML20070P900 + (ML20070P900)
- 05000387/LER-1982-074, Forwards LER 82-074/03L-0 + (ML20070P901)
- ML20070P932 + (ML20070P932)
- 05000324/LER-1982-132, Forwards LER 82-132/03L-0 + (ML20070P936)
- ML20070P949 + (ML20070P949)
- 05000387/LER-1982-074-03, /03L-0:on 821216,during Startup Testing Program, Standby Liquid Control Tank Found Out of Spec.Sodium Pentaborate Added to Bring Concentration within Specs. Procedures Will Be Modified to Keep Tank at Higher Level + (ML20070P965)
- ML20070P966 + (ML20070P966)
- 05000324/LER-1982-132-03, /03L-0:on 821217,during Nitrogen Makeup to Primary Containment,Core Auxiliary Cooling Sys 1-inch Drywell Inlet PCIV 2-CAC-V48 Discovered Leaking by Closed Valve Seat. Cause Undetermined.Containment Integrity re-established + (ML20070Q005)
- ML20070Q012 + (ML20070Q012)
- 05000339/LER-1982-076, Forwards LER 82-076/03L-0 + (ML20070Q014)
- ML20070Q022 + (ML20070Q022)
- ML20070Q032 + (ML20070Q032)
- 05000416/LER-1982-174, Forwards LER 82-174/03L-0 + (ML20070Q042)
- ML20070Q071 + (ML20070Q071)
- 05000339/LER-1982-076-03, /03L-0:on 821225 & 26,quadrant Power Tilt Ratio Exceeded 1.02 & on 821226 Axial Flux Difference Went Outside Target Band.Cause Not Stated.Power Tilt Ratio & Flux Difference Brought within Tech Spec Limits + (ML20070Q080)
- ML20070Q105 + (ML20070Q105)
- ML20070Q107 + (ML20070Q107)
- ML20070Q119 + (ML20070Q119)
- BECO-91-037, Forwards Proprietary NRC Form 396,dtd 910227 for Tm Murphy, License OP-5429-3.Encl Withheld (Ref 10CFR2.790(a)(6)) + (ML20070Q144)
- ML20070Q149 + (ML20070Q149)
- HL-1541, Annual Environ Surveillance Rept for 1990 + (ML20070Q153)
- ML20070Q155 + (ML20070Q155)
- ML20070Q157 + (ML20070Q157)