- 05000412/LER-1994-007, :on 940611,FWI Signal Automatically Initiated Due to high-high Water Level in a Msiv.Caused by Lack of Operator Experience.Personnel Counseled & Licensed Personnel re-trained + (ML20070E226)
- ML20070E230 + (ML20070E230)
- ML20070E231 + (ML20070E231)
- ML20070E242 + (ML20070E242)
- 05000373/LER-1982-146, Forwards LER 82-146/03L-0 + (ML20070E243)
- ML20070E244 + (ML20070E244)
- ML20070E247 + (ML20070E247)
- ML20070E248 + (ML20070E248)
- 05000324/LER-1994-009-02, :on 940619,isolation Signal Was Verified to Be Invalid & Valve Was Left Closed to Bypass Elements Being Heated.Caused by Personnel Error.Disciplinary Action Has Been Taken W/Maintenance Personnel + (ML20070E249)
- 05000321/LER-1980-003, Forwards Revised LER 80-003/03X-1 + (ML20070E253)
- 05000305/LER-1982-034, Forwards LER 82-034/03L-0 + (ML20070E259)
- ML20070E260 + (ML20070E260)
- ML20070E261 + (ML20070E261)
- ML20070E266 + (ML20070E266)
- 05000305/LER-1982-034-03, /03L-0:on 821111,valve MS-100A,main Steam to Turbine Driven Auxiliary Feedwater Pump,Torqued Out When Closing.Caused by Torque Switch Sticking & Manual de-clutch Unit Out of Adjustment.Switch & Tripper Assembly Replaced + (ML20070E267)
- ML20070E269 + (ML20070E269)
- 05000373/LER-1982-146-03, /03L-0:on 821111,div II,1D18-N009C Monitor Discovered Drifting High.Caused by Failed Geiger-Muller Tube.Tube Replaced + (ML20070E271)
- 05000373/LER-1982-148, Forwards LER 82-148/03L-0 + (ML20070E273)
- U-602308, Special Rept:On 940607,determined Valid Failure of Div 1 EDG Had Occurred Due to Excessive Current.Replaced Failed Relay + (ML20070E283)
- ML20070E285 + (ML20070E285)
- 05000373/LER-1982-148-03, /03L-0:on 821112,Div II post-LOCA Oxygen Channel Indication Drifted Down to 4%.Caused by Instrument Drift, Resulting in False Indication.Adjustments Made to Sample Flows & Calibr Performed + (ML20070E287)
- ML20070E293 + (ML20070E293)
- ML20070E294 + (ML20070E294)
- 05000321/LER-1980-003-03, While Performing RHR Valve Operability Procedure,Outboard Shutdown Cooling Isolation Valve F008 Opened in 25.8-S.Caused by Normal Wear & Human Reaction Time.Valve Operator Adjusted + (ML20070E298)
- 05000325/LER-1994-010-01, :on 940620,discovered Both Units Received Isolation of CAC System.Caused by Personnel Error.Personnel Responsible for Painting Have Been Instructed on Use of Ladders or Scaffolding for Work + (ML20070E306)
- ML20070E309 + (ML20070E309)
- BSEP-94-0258, Responds to NRC Re Violations Noted in Insp Rept 50-324/94-13 & 50-325/94-13.Corrective Actions:Operators Have Been Counseled & Appropriate Disciplinary Action Has Been Taken + (ML20070E310)
- 05000416/LER-1982-130, Forwards LER 82-130/03L-0 + (ML20070E316)
- ML20070E318 + (ML20070E318)
- ML20070E321 + (ML20070E321)
- 05000416/LER-1982-130-03, /03L-0:on 821112,shutdown Cooling Loops a & B of RHR Sys Simultaneously Inoperative.Caused by Need to Bring Down Loop a to Perform Surveillance Tests & Add Water to Reactor Vessel.Surveillance Performed + (ML20070E328)
- ML20070E331 + (ML20070E331)
- 2CAN128207, Forwards Proprietary & Nonproprietary Slides, Fuel Shoulder Gap Mod, Used at 821006 Meeting Re Fuel Shoulder Gap Problem.Affidavit from C-E Encl.Slides Withheld (Ref 10CFR2.790) + (ML20070E336)
- ML20070E338 + (ML20070E338)
- ML20070E341 + (ML20070E341)
- BSEP-82-2811, Ro:On 821209,while Performing Corrective Maint on Main Steam Line High Flow Isolation Instrument,Group I Isolation Signal Mistakenly Reset.Placement of Jumpers in Control Logic Allowed Resetting of Isolation.Signal Reinserted + (ML20070E342)
- 05000249/LER-1982-046, Forwards LER 82-046/03L-0 + (ML20070E344)
- ML20070E346 + (ML20070E346)
- ML20070E351 + (ML20070E351)
- 05000416/LER-1982-122, Forwards LER 82-122/99X-0 + (ML20070E352)
- ML20070E358 + (ML20070E358)
- 05000249/LER-1982-046-03, /03L-0:on 821112,water Discovered Spraying from 1-inch Drain Line Off Bottom of Feedwater Regulator Isolation Valve 3A.Caused by Cracked Weld at 1-inch Chain Line Due to Stresses from Thermal Effects + (ML20070E362)
- ML20070E364 + (ML20070E364)
- 05000416/LER-1982-122-99, /99X-0:on 821104,during Shutdown,Cover to HVAC Chase on Elevation 148 Ft in Control Bldg Lower Cable Spreading Room Found Removed.Cause Unknown.Cover Reinstalled.Investigation Continuing + (ML20070E366)
- 05000316/LER-1982-092-03, /03L-0:on 821109,during Normal Operation,Auxiliary Cable Vault (Zone 11) Experienced Inadvertent Carbon Dioxide Discharge & Pyralarm Detector Alarming.Caused by Water Entering Base.Detector & Base Replaced + (ML20070E371)
- ML20070E372 + (ML20070E372)
- 05000373/LER-1982-147, Forwards LER 82-147/03L-0 + (ML20070E380)
- ML20070E383 + (ML20070E383)
- ML20070E385 + (ML20070E385)
- 05000316/LER-1982-094-03, /03L-0:on 821122,during Mode 5 Operation,Rcs Temp Decreased Below Tech Spec Limit for Charging Pump Operation. Caused by Loss of Four Reactor Coolant Pumps & RHR Trains. Two of Three Pumps Racked Out + (ML20070E386)