Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20069G729 + (ML20069G729)
- RBG-40616, Forwards Required Certificate of Insurance Verifying Property Policies for Protection Against Financial Losses Due to Nuclear Accidents for River Bend Station + (ML20069G731)
- 05000315/LER-1982-101-01, During Surveillance Test, Motor Operated Valve WMO-753 to West Turbine Driven Auxiliary Feed Pump Would Not Open.Caused by Valve & Exhaust Fan for Turbine Driven Auxiliary Feed Pump Room Malfunction + (ML20069G732)
- ML20069G739 + (ML20069G739)
- ML20069G743 + (ML20069G743)
- RBG-14-644, Interim Deficiency Rept DR-97 Re Clearance Between Armature Tail Piece & Molded Posts of Hma Auxiliary Relays Mfg by GE in 1974.Initially Reported on 830217.Investigation Continuing.Interim or Final Rept Due by 830624 + (ML20069G749)
- 05000306/LER-1983-002, Forwards LER 83-002/03L-0 + (ML20069G753)
- ML20069G760 + (ML20069G760)
- 05000271/LER-1982-020, Forwards LER 82-020/03L-0 + (ML20069G765)
- ML20069G768 + (ML20069G768)
- 05000271/LER-1982-020-03, /03L-0:on 820902,indication on RHR 89B Blinked on & Off at 2,700 Gpm Flow Rate.Indication Lost When Valve Shut.Caused by Loose Wiring on Valve Limit Switch Resulting in Loss of Position Indication.Connection Tightened + (ML20069G771)
- 05000373/LER-1982-104, Forwards LER 82-104/03L-0 + (ML20069G772)
- 05000373/LER-1982-104-03, /03L-0:on 820916,offgas Sys Hydrogen Analyzers Found Reading Erroneously.Caused by Stock Solenoid Valve on a Train Analyzer & Defective Sensor on B Train Analyzer. Solenoid Cleaned & Sensor Replaced + (ML20069G775)
- 05000306/LER-1983-002-03, /03L-0:on 830216,control Switches for Heat Trace Circuits ET2R & ET47R Found in Off Position.Caused by Personnel Error.Switches Returned to Automatic Position + (ML20069G777)
- 05000333/LER-1982-044, Forwards LER 82-044/03L-0 + (ML20069G780)
- 05000333/LER-1982-044-03, /03L-0:on 820909,motor Operator Electrical Breaker Tripped While Attempting to Cycle LPCI Injection Valve. Caused by Electrical Motor Fault Resulting in Isolation Failure Created During Attempted Valve Cycling + (ML20069G784)
- 05000368/LER-1983-011, Forwards LER 83-011/03L-0 + (ML20069G785)
- ML20069G789 + (ML20069G789)
- ML20069G790 + (ML20069G790)
- ML20069G791 + (ML20069G791)
- ML20069G792 + (ML20069G792)
- ML20069G793 + (ML20069G793)
- ML20069G796 + (ML20069G796)
- ML20069G801 + (ML20069G801)
- ML20069G808 + (ML20069G808)
- ST-HL-AE-4736, Application for Amends to Licenses NPF-76 & NPF-80,revising TS 3.8.1.1 by Eliminating Excessive & Unnecessary Testing of Standby Diesel Generators + (ML20069G823)
- 05000261/LER-1980-027, Updated LER 80-027/01T-1:on 801122,relay RT-9 in Reactor Protection Train a Failed to re-energize During Periodic Test of Reactor Protection Logic.Caused by Shorting of Lead Wire Connection to Coil Wires.Relay Replaced + (ML20069G827)
- ML20069G829 + (ML20069G829)
- ML20069G835 + (ML20069G835)
- ML20069G841 + (ML20069G841)
- ML20069G842 + (ML20069G842)
- 05000338/LER-1982-062, Forwards LER 82-062/03L-0 + (ML20069G844)
- ML20069G851 + (ML20069G851)
- ML20069G854 + (ML20069G854)
- 05000338/LER-1982-062-03, /03L-0:on 820917,cold Leg Injection Line Check Valve Found W/Five Corroded Bolts.Caused by Small Leak at Body to Bonnet Gasket.Studs & Bonnet Gasket Replaced + (ML20069G857)
- 05000334/LER-1982-034, Forwards LER 82-034/03L-0 + (ML20069G866)
- 05000315/LER-1982-083-03, /03L-0:on 820921,during Hot Standby Following Refueling,Leak Observed on Isolation Valve CS-422N. Caused by Failure of 2-inch Grinnell Grade M Diaphragm. Diaphragm Replaced + (ML20069G869)
- ML20069G871 + (ML20069G871)
- ML20069G873 + (ML20069G873)
- 05000334/LER-1982-034-03, /03L-0:on 820915,during Surveillance Test Containment Vacuum Pump Failed Required Discharge Flow Rate. Caused by Buildup of Dirt & Debris in Discharge Line.Line Cleaned & Suction & Discharge Filters Replaced + (ML20069G878)
- ML20069G880 + (ML20069G880)
- ML20069G881 + (ML20069G881)
- 05000368/LER-1983-011-03, /03L-0:on 830218,during Mode 3 & Feeding of Steam Generators W/Emergency Feedwater Pump 2P-7B,control Valve 2CV-1036 Failed to Close.Caused by Shorted Relay Coil Ite Imperial 220-EB220PA-5.Relay Replaced W/Gould Relay + (ML20069G882)
- 05000315/LER-1982-085-03, /03L-0:on 820927,during Hot Standby Following Refueling,Steam Generator 2 Stop Dump Valve MRV-221 Removed from Svc.Caused by Need to Correct Seat Leakage.Valve Disc, Seat & Stem Replaced + (ML20069G887)
- ML20069G891 + (ML20069G891)
- 05000263/LER-1982-016, Forwards LER 82-016/01T-0 + (ML20069G892)
- 05000317/LER-1980-041, Forwards Updated LER 80-041/01X-1 + (ML20069G897)
- ML20069G898 + (ML20069G898)
- 05000263/LER-1982-016-01, /01T-0:on 820928,three Indications in 22-inch Diameter Reactor Recirculation Sys Riser Manifold End Cap Confirmed as Rejectable.Caused by Intergranular Stress Corrosion Cracking.End Cap to Be Replaced + (ML20069G901)
- ML20069G905 + (ML20069G905)
- 05000317/LER-1980-041-01, 5 Minutes After Svc,Water Head Tanks Went from Normal Operating Level to Full,Isophase Bus Duct Cooling Low Flow Alarm Received.Caused by Air Compressor Failure Due to Cracked After Cooler Tubes + (ML20069G909)