Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20066A816 + (ML20066A816)
- 05000373/LER-1982-112-03, /03L-0:on 820929,during Performance of LIS-NB-01, DPIS-1B21-N024D Setpoint for Reactor Vessel Low Water Level Scram Found Out of Calibr.Caused by Instrument Drift.Switch Recalibr.Revision in Progress to Change Tolerance Setp + (ML20066A817)
- NRC-90-0186, Submits Update to Simulator Upgrade Project Schedule. Exemption Request from 10CFR50.12, Specific Exemptions Will Be Submitted in Jan 1991 to Provide Required Simulator Certification to NRC Later in 1991 + (ML20066A818)
- NRC-90-0170, Responds to Violations Noted in Insp Rept 50-341/90-18. Corrective Actions:Personnel Assigned to Survey Radioactive Matl Shipments Will Receive Training on Revised Procedure 67.000.103 Re Survey of Radwaste Shipment Vehicles + (ML20066A820)
- ML20066A826 + (ML20066A826)
- 05000373/LER-1982-133, Forwards LER 82-133/03L-0 + (ML20066A830)
- A820020, Forwards Revision to Inservice Testing Relief Requests Re Pump Vibration Testing + (ML20066A834)
- ML20066A835 + (ML20066A835)
- ML20066A838 + (ML20066A838)
- ML20066A841 + (ML20066A841)
- ML20066A844 + (ML20066A844)
- ML20066A847 + (ML20066A847)
- 05000373/LER-1982-133-03, /03L-0:on 820930,RHR Svc Water 1C Pump auto-tripped During LOP-RH-09,rendering Pump Inoperable. Caused by Motor Failure Due to Phase to Ground Fault in Motor Field Windings.Motor Replaced + (ML20066A848)
- ML20066A849 + (ML20066A849)
- ML20066A852 + (ML20066A852)
- ML20066A854 + (ML20066A854)
- ML20066A856 + (ML20066A856)
- ML20066A857 + (ML20066A857)
- ML20066A858 + (ML20066A858)
- ML20066A860 + (ML20066A860)
- ML20066A862 + (ML20066A862)
- ML20066A864 + (ML20066A864)
- ML20066A865 + (ML20066A865)
- ML20066A871 + (ML20066A871)
- ML20066A872 + (ML20066A872)
- RBG-13-412, Corrected Final Deficiency Rept DR-38 Re Difference in Serration Patterns of PS-10RS Spring Nuts.Addl Clarification of Dichromated PS-9227RS-1/2 Nut & Corrected Typographical Errors Incorporated + (ML20066A873)
- ML20066A879 + (ML20066A879)
- ML20066A887 + (ML20066A887)
- ML20066A889 + (ML20066A889)
- ML20066A892 + (ML20066A892)
- 05000311/LER-1982-115, Forwards LER 82-115/03L-0.Detailed Event Analysis Encl + (ML20066A893)
- 05000318/LER-1982-045, Forwards LER 82-045/03L-0 + (ML20066A896)
- 05000311/LER-1982-115-03, /03L-0:on 820928,svc Water Leak Found on 2A Emergency Diesel Generator Oil Cooler Piping.Caused by Silt in Svc Water Triggering Accelerated Erosion.Failed Pipe Cap Replaced + (ML20066A903)
- ML20066A905 + (ML20066A905)
- 05000255/LER-1982-034, Forwards LER 82-034/03L-0 + (ML20066A907)
- 05000318/LER-1982-045-03, /03L-0:on 821001,reactor Protection Sys Low Flow Trip Unit on Channel a Failed.Caused by Failed Low Power Supply (Lambda Part LCD-2-44).Failed Power Supply Replaced & Sent to Vendor for Analysis & Repair + (ML20066A910)
- ML20066A913 + (ML20066A913)
- 05000247/LER-1982-042, Forwards LER 82-042/03L-0 + (ML20066A922)
- ML20066A927 + (ML20066A927)
- 05000266/LER-1982-009, Telecopy Message of LER 82-009/01T-0:on 821030,tubes in Steam Generators a & B Found W/More than 40% Degradation.On 821025,insp Revealed 5 Wet or Dripping Explosive Plugs.No Cause Stated.Tubes Plugged + (ML20066A929)
- 05000255/LER-1982-034-03, /03L-0:on 821002,malfunction of Fire Sprinkler Alarm Resulted in Alarm on Panels C-47 & C-13.Panel C-13 W/O Reflash Capability & C-47 Not in Operator Line of Vision. Detector Repaired.Design Change Under Consideration + (ML20066A931)
- 05000247/LER-1982-042-03, /03L-0:on 820923,one of Two Level Alarm Setpoints Found Above Max Level Per Tech Specs.Caused by Level Alarm Bistable Setpoint Drift.Setpoint Reset to Required Value. Surveillance Frequency Increased + (ML20066A933)
- 05000302/LER-1982-062, Forwards LER 82-062/01T-0 + (ML20066A935)
- ML20066A939 + (ML20066A939)
- 05000302/LER-1982-062-01, /01T-0:on 821014,received Confirmation That Pressurizer Code Safety Valves RCV-8 & RCV-9 Ring Settings May Cause Valves to Chatter or Fail to Reach Rated Lift. Caused by Inadequate Understanding.Valves Replaced + (ML20066A948)
- 05000456/LER-1990-020-02, :on 901129,auxiliary Bldg Inaccessible Filter Plenum Charcoal Booster Fan OB,OVA03CB Spuriously Auto Started.Caused by Component Failure.Relay Replaced & Fan Circuitry & Breaker Checked + (ML20066A950)
- 05000395/LER-1982-010, Forwards LER 82-010/03L-0.Detailed Event Analysis Encl + (ML20066A952)
- 05000311/LER-1982-002, Supplemental LER 82-002/03X-1:on 820111,battery Charger 2A1 Tripped.Charger Tripped Again Upon Resetting Breaker.Caused by Difference Between Battery & Battery Charger Voltages. Operating Instructions Revised to Adjust Float Vo + (ML20066A956)
- 05000395/LER-1982-010-03, /03L-0:on 821001,PORV Block Valve MVG-8000A Would Not Reopen at Conclusion of Reactor Vessel O-ring Leak Test. Caused by Wear in Valve Stem Packing Which Contributed to Overtorque Condition.Stem Packing Replaced + (ML20066A959)
- ML20066A965 + (ML20066A965)
- B13692, Requests Relief from ASME Code Section XI Requirements,Per 10CFR50.55a(g)(6)(i) to Allow Svc Water Pump C to Be Declared Operable & Returned to Normal Operational Lineup + (ML20066A971)