Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000280/LER-1982-054-03, /03L-0:on 820905,unattended Portable Pump in Use to Clean Waterbox C Swung Around & Flooded Svc Water Pit Containing Svc Water.Valve MOV-SW-202B Grounded in Open Position.Caused by Operator error.MOV-SW-202B Dried + (ML20065H374)
- 05000280/LER-1982-092-03, /03L-0:on 820905,at Full Power,Rpi F-8 Observed Fluctuating Up to 15 Steps.Caused by Exposure of Containment Side Electrical Penetration to Excessive Moisture & Faulty Signal.Steam Leak Repaired + (ML20065H377)
- ML20065H378 + (ML20065H378)
- ML20065H385 + (ML20065H385)
- ML20065H391 + (ML20065H391)
- ML20065H392 + (ML20065H392)
- ML20065H396 + (ML20065H396)
- 05000361/LER-1982-100-03, /03L-0:on 820825,turbine of Auxiliary Feedwater Pump 2P-140 Tripped.Attempts to Start Pump Failed.Caused by Moisture in Steam Supply Header & Throttle Valve.Steam Traps Blown Down at 2-h Intervals.Drains Modified & Under Stu + (ML20065H398)
- 05000361/LER-1982-101-03, /03L-0:on 820827,turbine of Auxiliary Feedwater Pump 2P-140 Tripped on High Speed.Attempts to Restart Pump Failed.Caused by Defective Speed Sensor.Speed Sensor Replaced + (ML20065H401)
- ML20065H402 + (ML20065H402)
- ML20065H419 + (ML20065H419)
- ML20065H424 + (ML20065H424)
- ML20065H428 + (ML20065H428)
- ML20065H433 + (ML20065H433)
- ML20065H437 + (ML20065H437)
- ML20065H440 + (ML20065H440)
- ML20065H443 + (ML20065H443)
- ML20065H444 + (ML20065H444)
- 05000293/LER-1990-016, :on 900917,automatic Actuation of Main Steam Sys/Group 1 Portion of PCIS Occurred + (ML20065H450)
- ML20065H453 + (ML20065H453)
- ML20065H456 + (ML20065H456)
- ML20065H467 + (ML20065H467)
- ML20065H468 + (ML20065H468)
- ML20065H472 + (ML20065H472)
- ML20065H488 + (ML20065H488)
- 05000353/LER-1990-017-02, :on 900916,inadvertent Actuation of Primary Containment & Reactor Vessel Isolation Control Sys Occurred + (ML20065H514)
- ML20065H515 + (ML20065H515)
- ML20065H521 + (ML20065H521)
- ML20065H522 + (ML20065H522)
- PY-CEI-NRR-1248, Special Rept:On 900913,HPCS Piping Triaxial Peak Accelerograph Recorder Could Not Be Calibr.On 900917, Recorder Found Outside Allowable Value.Caused by Damaged Internal Components.Replacement Procured & Calibr + (ML20065H523)
- ML20065H526 + (ML20065H526)
- ML20065H529 + (ML20065H529)
- ML20065H531 + (ML20065H531)
- ML20065H535 + (ML20065H535)
- ML20065H539 + (ML20065H539)
- ML20065H545 + (ML20065H545)
- ML20065H548 + (ML20065H548)
- ML20065H551 + (ML20065H551)
- ML20065H553 + (ML20065H553)
- ML20065H554 + (ML20065H554)
- 05000445/LER-1990-027, :on 900907,manual Reactor Trip Due to Shearing of Feedwater Flow Control Valve Feedback Linkage Arm.W/ + (ML20065H556)
- ML20065H557 + (ML20065H557)
- ML20065H560 + (ML20065H560)
- NPL-94-0137, Informs of Completion of Detailed Control Room Design Review Actions for Point Beach Nuclear Plant,Units 1 & 2 + (ML20065H563)
- ML20065H569 + (ML20065H569)
- ML20065H593 + (ML20065H593)
- ML20065H594 + (ML20065H594)
- 05000352/LER-1990-019-01, :on 900915,special Rept for Diesel Generator Surviellance Test Failure + (ML20065H603)
- ML20065H609 + (ML20065H609)
- ML20065H610 + (ML20065H610)