Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000445/LER-1990-028, :on 900908,automatic Reactor Trip Occurred Due to Lightning Strike + (ML20065G452)
- ML20065G455 + (ML20065G455)
- ML20065G457 + (ML20065G457)
- TXX-9409, Forwards Annual Rept of Changes in Peak Cladding Temp,In Accordance W/Requirements of 10CFR50.46(a)(3)(ii) + (ML20065G458)
- ML20065G459 + (ML20065G459)
- 05000247/LER-1982-032, Forwards LER 82-032/01T-0 + (ML20065G465)
- ML20065G467 + (ML20065G467)
- ML20065G468 + (ML20065G468)
- 05000317/LER-1982-051, Forwards LER 82-051/03L-0 + (ML20065G473)
- ML20065G478 + (ML20065G478)
- ML20065G480 + (ML20065G480)
- 05000317/LER-1982-051-03, /03L-0:on 820827,plant Air Header Isolation Valve Inside containment,1-PA-1040,found Open.Caused by Valve Being Inadvertently Left Open While Securing Plant Air to Containment on 820822.Standing Instruction Issued + (ML20065G484)
- 05000247/LER-1982-032-01, /01T-0:on 820817,blowdown Outer Isolation Valve PCV 1215A Failed Closed Due to Failure of Solenoid Valve SOV 1315A.Caused by Open Circuit in Pilot Solenoid Valve SOV 1315A Coil.Coil Replaced + (ML20065G494)
- ML20065G504 + (ML20065G504)
- SVP-94-021, Responds to Violation Noted in Insp Rept 50-456/94-03 & 50-457/94-03.Corrective Actions:Chemistry Inline Quality Control Program to Be Restored by 940630 + (ML20065G513)
- ML20065G515 + (ML20065G515)
- ML20065G526 + (ML20065G526)
- ML20065G529 + (ML20065G529)
- ML20065G534 + (ML20065G534)
- ML20065G540 + (ML20065G540)
- 05000305/LER-1982-028, Forwards LER 82-028/03L-0 & Updated 81-036/03X-1 + (ML20065G546)
- 05000454/LER-1994-002-09, :on 940309,main Steam Safety Valves Setpoints Found Out of Tolerance Due to Calculation Error.Amend to TSs to Allow Tolerance of +3% Requested.Valve Setpoints Will Be Retested by 940509 + (ML20065G552)
- ML20065G557 + (ML20065G557)
- ML20065G559 + (ML20065G559)
- 05000305/LER-1982-028-03, /03L-0:on 820825,damper on Train a Failed Open Causing Zone Special Ventilation Fan to Start Automatically. Caused by Bad Coil on Solenoid Controlling Exhaust Filter Inlet Damper.Coil Replaced + (ML20065G568)
- ML20065G571 + (ML20065G571)
- 05000305/LER-1981-036-03, Motor Drive Auxiliary Feedwater Lube Oil Pump Continued to Run When Pump 1A Stopped.Caused by Excessive Wear & Misalignment of Switch Linkage Mechanism.Worn Parts Replaced + (ML20065G575)
- ML20065G576 + (ML20065G576)
- BVY-90-096, Forwards Rev 0 to Vermont Yankee Nuclear Power Station Cycle 15 Core Operating Limits Rept + (ML20065G577)
- NRC-94-4090, Forwards Proprietary Version of Quick Look Rept for Large Scale Pccs Test 222.1,AP600 Program. Rept Withheld,Per 10CFR2.790 + (ML20065G580)
- ML20065G583 + (ML20065G583)
- ML20065G585 + (ML20065G585)
- ML20065G586 + (ML20065G586)
- ML20065G587 + (ML20065G587)
- ML20065G588 + (ML20065G588)
- ML20065G590 + (ML20065G590)
- 05000456/LER-1994-004-05, :on 940309,improper Value for Mean Seat Area Was Used in Trevitest Calculation for MSSV Setpoints.Caused by Programmatic Deficiency.Mssvs Will Be Reset on or Before 940409 + (ML20065G623)
- 05000285/LER-1982-018, Forwards LER 82-018/01T-0 + (ML20065G624)
- 05000285/LER-1982-018-01, /01T-0:on 820917,review of electro-pneumatic (E/P) Valve Positioners Revealed Absence of Analysis or Test Qualification Data for Honeywell Model 67400-023 Positioners.Control Circuit,Solenoid Valves to Be Modified + (ML20065G629)
- ML20065G644 + (ML20065G644)
- ML20065G646 + (ML20065G646)
- ML20065G649 + (ML20065G649)
- ML20065G657 + (ML20065G657)
- ML20065G659 + (ML20065G659)
- ML20065G665 + (ML20065G665)
- 05000456/LER-1994-003-05, :on 940311,as Found Integrated Leak Rate Test Failures Occurred.Caused by Preservice Const Deficiencies. Missing Caps on Emergency Hatch Concrete Vent Pipes Installed & Test Reperformed Satisfactorily + (ML20065G672)
- ML20065G674 + (ML20065G674)
- ML20065G678 + (ML20065G678)
- NRC-94-4081, Forwards Nonproprietary & Proprietary Versions of Presentation Matls from 940314 Meeting on AP600 Core Makeup Tank Tests & Analysis.Proprietary Version of Presentation Matls Withheld,Per 10CFR9.17(a)(4) & 10CFR2.790 + (ML20065G679)
- ML20065G681 + (ML20065G681)