Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20065E603 + (ML20065E603)
- ML20065E609 + (ML20065E609)
- ML20065E616 + (ML20065E616)
- ML20065E629 + (ML20065E629)
- ML20065E642 + (ML20065E642)
- 05000348/LER-1982-052-03, /03L-0:on 820831,during Control Room Emergency Ventilation Performance Test,B Train Emergency Air Cleanup Sys Failed to Meet Acceptance Criteria.Caused by Failure of Charcoal Filter to Meet Efficiency Requirements + (ML20065E644)
- 05000338/LER-1982-058, Forwards LER 82-058/03L-0 + (ML20065E649)
- 05000311/LER-1982-096, Forwards LER 82-096/03L-0.Detailed Event Analysis Encl + (ML20065E675)
- 05000338/LER-1982-058-03, /03L-0:on 820826,manipulator Crane Area Monitor RM-RMS-162 Failed to Meet Acceptance Criteria of Periodic Calibr & Declared Inoperable.Caused by Instrument Drift Greater than 3% Response Requirement.Assembly Replaced + (ML20065E679)
- 05000348/LER-1982-037-03, /03L-0:on 820905,A Train Auto Trip Logic for High Steam Generator Differential Pressure Declared Inoperable When Failed Cord Indication Received by Automatic Tester. Caused by Failure of Universal Card.Card Replaced + (ML20065E684)
- 3F0990-04, Informs of Continuing Activities at Facility to Clearly Define & Resolve post-accident Hydrogen Control Issues. Concludes That Sys Fully Capable of Performing Intended Function + (ML20065E685)
- TXX-9031, Submits Annual Rept of Changes in Peak Cladding Temps.No Changes in ECCS Calculations Occurred During Last 12 Months. Update Will Be Provided W/Unit 2 FSAR Amend for Optimized Fuel Assemblies + (ML20065E692)
- 05000311/LER-1982-096-03, /03L-0:on 820831,containment Fan Coil Unit 23 Declared Inoperable When Operator Received Indication of Low Svc Water Flow.Caused by Silt Buildup in Cooling Coils.Flow Control Valve Cycled & Unit Tested Satisfactorily + (ML20065E694)
- ML20065E695 + (ML20065E695)
- ML20065E697 + (ML20065E697)
- ML20065E701 + (ML20065E701)
- L-82-375, Responds to NRC Re Violations Noted in IE Insp Rept 50-335/82-01.Corrective Actions:Personnel Verbally Reinstructed Re Insp of Design Documents for Proper Erections,Implementation & Documentation + (ML20065E708)
- ELV-01901, Application for Amends to Licenses NPF-68 & NPF-81,revising Tech Spec (TS) 3.4.1.3 Re Starting Reactor Coolant Pump & Providing Consistency Between Ts,Rcs Analysis Assumptions Demonstrating Compliance W/App G Limits & RHR Analysis + (ML20065E712)
- ML20065E717 + (ML20065E717)
- 05000338/LER-1982-059, Forwards LER 82-059/03L-0 + (ML20065E763)
- 05000335/LER-1982-045, Forwards LER 82-045/43X-0 + (ML20065E771)
- ML20065E776 + (ML20065E776)
- ML20065E783 + (ML20065E783)
- 05000338/LER-1982-059-03, /03L-0:on 820827,ventilation Vent B Gaseous Radiation Detector Response Found to Exceed Calibr Test Acceptance Criteria.Caused by Gradual Deterioration of Photomultiplier Tube & Preamplifier.Parts Replaced + (ML20065E785)
- ML20065E789 + (ML20065E789)
- 05000413/LER-1993-003-04, :on 930925,reactor Tripped Due to Inadvertent Closure of Msiv.Caused by Inadequate Self Checking & Independent Verification of Intended Actions.Procedure IP/0/A/3890/01 Will Be Revised + (ML20065E800)
- 3F0394-15, Forwards Revised Page 2 to Response to Notice of Violation for Us Dept of Labor Case 88-ERA-29 + (ML20065E807)
- ML20065E808 + (ML20065E808)
- ML20065E810 + (ML20065E810)
- 05000335/LER-1982-045-43, /43X-0:on 820913,wash Trough Used to Decontaminate Respirators & Similar Items Found Not Draining Into Radwaste Sys.Caused by Error Resulting from Personnel Turnover.Drain Rerouted.Dump Area Surveys Will Continue + (ML20065E815)
- 05000387/LER-1982-014, Forwards LER 82-014/03L-0 + (ML20065E828)
- ML20065E838 + (ML20065E838)
- 05000387/LER-1982-014-03, /03L-0:on 820824,prior to Initial Criticality,Unit Taken from Operational Condition 5 to 4 W/O Shutdown Cooling Mode of RHR in Operation,As Required by Tech Spec.Initial Startup Procedure Superseded by Normal Startup Procedu + (ML20065E841)
- BSEP-82-1915, Suppls 820702 Response to NRC Re Violations Noted in IE Insp Repts 50-324/82-18 & 50-325/82-18.Corrective Actions:Responsible Operators Counseled & 1A-1 Battery Charger Clearance Removal Reviewed + (ML20065E858)
- ML20065E859 + (ML20065E859)
- BSEP-82-1483, Responds to NRC Re Violations Noted in IE Insp Repts 50-324/82-18 & 50-325/82-18.Corrective Actions:Double Verification Program Established on 820601 + (ML20065E869)
- ML20065E874 + (ML20065E874)
- 05000382/LER-1994-004-01, :on 940307,degraded CCW HX Discovered While Shutdown Due to Biological Fouling.Ccw HXs a & B Cleaned.W/ + (ML20065E882)
- ML20065E885 + (ML20065E885)
- ML20065E891 + (ML20065E891)
- ML20065E894 + (ML20065E894)
- ML20065E896 + (ML20065E896)
- ML20065E898 + (ML20065E898)
- ML20065E909 + (ML20065E909)
- AECM-90-0168, Forwards Vols 1-3 to Grand Gulf Nuclear Station Dcrdr Supplemental Summary Rept. Rept Provides Addl Info as Discussed in NRC 900605 Safety Evaluation,Including Schedule for Correcting Category 3 Human Engineering Discrepancies + (ML20065E910)
- ML20065E912 + (ML20065E912)
- PY-CEI-NRR-1765, Forwards Rev 3 to Pump & Valve IST Program Plan & Responses to Open Issues Involving Plan Identified in 930405 Safety Evaluation + (ML20065E924)
- ML20065E934 + (ML20065E934)
- 05000338/LER-1982-050, Forwards LER 82-050/03L-0 + (ML20065E948)
- ML20065E949 + (ML20065E949)
- DCL-90-219, Forwards Public Version of Revised Epips,Including Rev 11 to EPG-4 & Rev 3 to EP RB-4.W/DH Grimsley 900924 Release Memo + (ML20065E972)